Warranty Registration / Start-Up Form - Vogt HE S Series Installation & Start-Up Instructions

Tube-ice machine
Table of Contents

Advertisement

Tube Ice L.L.C.
Installation & Start-up – HES Series
1000 W. Ormsby
Louisville, KY 40210
(502) 635-3235
FAX #502-635-3024
Model Number: __________________________
This form must be filled out completely and signed by the customer in order to assure acceptance by Vogt.
Date of Start-Up:
___________________
AC Condenser Model Number: ____________________
Water Treatment System?
Bin Manufacturer: _______________________
Distributor
Company Name: ____________________________________________
Address: ____________________________________ City: _________________________ State: ___________ Zip: ___________
Service Company
Company Name: ____________________________________________
Address: ____________________________________ City: _________________________ State: ___________ Zip: ___________
Customer (location of equipment)
Company Name: ____________________________________________
Address: ____________________________________ City: _________________________ State: ___________ Zip: ___________
______ V _____ PH _____ HZ Power (check supply (actual) at machine)—Notice: Call Vogt if under 195 V
Crankcase heater on for 2 hours minimum, prior to start
All valves opened or closed as tagged
Water supply and drains connected properly
AC condenser cold weather temperature setting(s)
AC condenser installed above machine:
AC condenser properly piped—are all lines insulated (see installation and start-up instructions)?
AC condenser line length (in equivalent feet (see installation instructions)) ____________
Leak checked entire system including AC condenser and lines (if applicable)
Sufficient make-up water supply (minimum 30 PSIG)
Make-up water float valve adjustment
Compressor oil level, i.e. 1/4 – 1/2 – 3/4: ______
Compressor amps (check at start of freeze cycle) L1 _________
Cutter motor amps __________
Water pump amps __________
Condenser motor amps (if applicable) _________
Inside ambient _______ °F
Bin control (s) installed properly
Bin control (s) operate properly to stop and start machine with ice on them
Average hole diameter of ice ______
Freezing cycle time:
CYL ________
First ice out:
CYL ________
Instruction manual and warranty certificate left on-site
Remarks:_______________________________________________________________________________________________________
Technician Signature: ______________________________
I certify that I have performed all of the above procedures.

Warranty Registration / Start-Up Form

HES20, HES30, HES40
Yes
No
Manufacturer: ____________________
Model: _________________________
PRE-OPERATION CHECK
Yes
(Should not be over 4.1 amps cutting ice—if over, call Vogt)
(Should not be over 5.0 amps—if over, call Vogt)
(If temperature is below 50°F, call Vogt)
Clear ice
CRU ________
CRU ________
VOGT TO ACTIVATE WARRANTY
Serial Number: __________________________
Form Completed By: _____________________________________
AC Condenser Serial Number: _____________________________
Phone: _______________________
Phone: _______________________
Phone: _______________________
Solenoid ________
Fan (HES30 & HES40 only)________
No
Approx. _____ ft.
Incoming potable water temperature: _____°F
L2 _________
Yes
No
Harvest cycle time:
CYL _______
All ice out time:
CYL _______
Name of person left with: ______________________________
End User Signature: _____________________________
44
Vogt Order Number: _______________
THIS FORM MUST BE SENT TO
Model: ________________________
Bin Capacity: _______ lbs.
L3 _________
CRU _______
CRU _______

Advertisement

Table of Contents
loading