VT-Series
Ice Maker
Model
VT40, VT60, VT80, VT100
Revision Date: 1/04/12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VT40 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vogt VT40

  • Page 1 VT-Series Ice Maker Model VT40, VT60, VT80, VT100 Revision Date: 1/04/12...
  • Page 2 NOTICE This manual is the property of the owner of this particular Vogt Tube-Ice® machine. Model #____________________ Serial #____________________. It is to be left on the premises with this machine at all times. After start-up, it should be stored in a safe place where it can be readily available when needed for future reference in maintaining troubleshooting or servicing.
  • Page 3 If, at any time, you encounter conditions that we have not addressed in this manual, ® we welcome you to write or call Vogt Ice, LLC and we will give your questions our immediate attention and reply. Vogt Ice ® , LLC 1000 W.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS General Information - Section 1 History of Company..................... 1-1 Receipt of Your Ice Machine ................1-2 Installation Information - Section 2 Important Safety Notice..................2-1 Machine Dimension..................... 2-2 Machine Weights & Refrigerant Line Sizes............2-2 Ice Chute Cutout ....................2-3 Water Connections....................
  • Page 5 Maintenance - Section 6 Preventive Maintenance ..................6-1 Preventive Maintenance Program ............... 6-2 Air Cooled Condenser Cleaning ................6-3 Compressor Oil ....................6-3 Chopper Gear Reducer Oil .................. 6-4 Water Distributor ....................6-4 Troubleshooting - Section 7 Machine Fault Light .................... 7-1 Control Power Light ....................
  • Page 6: General Information - Section

    ISTORY OF OMPANY Henry Vogt Machine Co. was founded as a small machine shop in Louisville, Kentucky in 1880. In 1938, Vogt built the first Tube-Ice ® machine and revolutionized the ice-making industry. Our first “sized-ice” machine quickly replaced the old can-ice plants, which required much hard labor and large amounts of floor space for freezing, cutting, and crushing ice by hand.
  • Page 7: Receipt Of Your Ice Machine

    (i.e., the trucker’s Bill of Lading). Immediately make a separate written request for inspection by the freight line’s agent. Any repair work or alteration to the machine without the permission of the Vogt Ice can void the machine’s warranty. You should also notify your Vogt distributor or the factory.
  • Page 8: Installation Information - Section

    ® Vogt VT Service Manual Installation Instructions Installation Information Important Safety Notice. This information is intended for use by individuals possessing adequate backgrounds of electrical, refrigeration and mechanical experience. Any attempt to repair major equipment may result in personal injury and property damage. The manufacturer or seller cannot be responsible for the interpretation of this information, nor can it assume any liability in connection with its use.
  • Page 9: Machine Dimension

    ® Vogt VT Service Manual Installation Instructions 58" - VT40, VT60 & VT80 71" - VT100 FIGURE 2-1 Ice Machine Dimensions Unit "A" "B" "C" "D" "E" "F" VT40 72 5/8" 27" 24 3/8" 50 3/4" 44" 34" VT60 89"...
  • Page 10: Ice Chute Cutout

    Using drawing and table below, determine ice machine location so that it is centered on bin. Place ice machine on ice storage unit and bolt in place. Machine must be level front to back and side to side for proper operation. 27” (VT40) 39 1/2” (VT60, VT80 & VT100) Skid Mounted 27”...
  • Page 11 Installation Instructions Makeup water, water tank drain and water tank overflow are ½” FPT connections FIGURE 2-3 VT Lowside Water and Electrical Connections – Rear View Makeup Water Flow VT40 VT60 VT80 VT100 Usage - Gallons /100 lbs of Ice Flow rate –...
  • Page 12: Electrical Connections

    Wiring And Electrical Connection. WARNING Only service personnel experienced in refrigeration and qualified to work with high ® voltage electrical equipment should be allowed to install or work on the Vogt Series Ice machine. WARNING Main Power: Power for the entire ice machine will be supplied at the condensing unit.
  • Page 13: Lowside Electrical Connections

    ® Vogt VT Service Manual Installation Instructions Air Cooled Condenser Wiring: Run two #14 AWG wires from the terminals T4 and T5 on the condensing unit control panel terminal block to the air cooled condenser control panel. Note: 400/460V VT-80 & VT100’s run 3 #14 AWG wires from terminals L6, L7& L8 to air cooled condenser.
  • Page 14: Air Cooled Condenser Installation

    ® Vogt VT Service Manual Installation Instructions Power is supplied to the lowside through circuit breaker (CB1) located in the condensing unit control panel. See diagram below. CB1 supplies power to lowside unit Condensing unit control panel FIGURE 2-7 Condensing Unit Circuit Breakers (200/230V) Air Cooled Condenser Installation (VT80 &...
  • Page 15 ® Vogt VT Service Manual Installation Instructions Must solder with 45% silver solder Liquid return from Air Cooled Condenser (7/8” line) Discharge gas to Air Cooled Condenser VT80 - 1 1/8” VT100 – 1 3/8” Teflon Seal 12A2600T01 (for 1 1/4”-12 thread fitting) Female Rota-lock Adapters: 12A2600T03 (for 1 3/4”-12 thread fitting)
  • Page 16: Air Cooled Condenser Wiring

    VT80 & VT100 Remote Air Cooled Condenser Wiring Note: Fan control pressure switch is located in air cooled condenser control panel on VT80 & VT100’s with remote condensers. On VT40’s and VT60’s, fan control pressure switch is location on condensing unit (highside).
  • Page 17 12A2600T03 (for 1 3/4”-12 thread fitting) 7/8” IDS X 1 1/4”-12 Threads Rota-lock Adapter Teflon Seal Where Used Part # Description Part # VT40 VT60 12A2396A0501 1 1/8” IDS X 1 1/4”-12Thrd 12A2600T01 Hot Gas Line 12A2396A0601 1 3/8” IDS X 1 3/4”-12Thrd...
  • Page 18 ® Vogt VT Service Manual 2-11 Installation Instructions Control Panel FIGURE 2-13 VT60 Condensing Unit Connections Control Panel FIGURE 2-14 VT40 Condensing Unit Connections...
  • Page 19 ® 2-12 Vogt VT Service Manual Installation Instructions Storing Ice. When storing ice in a bin, make sure the bin control sensor is mounted in the bin properly. The sensor should be mounted on the right side of the bin approximately 8” –12” from the top of the bin.
  • Page 20: Ice Bin Capacity

    Always allow enough room below the chute for at least one harvest. VT40 = 25-30 lbs. / cycle VT60 & VT80 = 35-40 lbs. / cycle...
  • Page 21 ® 2-14 Vogt VT Service Manual Installation Instructions Blank...
  • Page 22: Model Specifications

    ® Vogt VT Service Manual Model Specifications Model Specifications Electric VT-40 VT-60 VT-80 VT-100 Volts/ Phase/ Hertz 208/230-3-60 Total F.L.A. Rating 46.1 56.4 67.2 80.8 Minimum Circuit Ampacity 54.0 66.9 80.4 97.3 Maximum Circuit Breaker ® ® Compressor (Copeland Discus Compressor 5.5 HP...
  • Page 23: Model Number Structure

    ® Vogt VT Service Manual Model Specifications Vogt Ice Vertical Tube Model Number Structure VT 6 B – P F 26 AC H G 00 Basic Model “VT” – Vertical Tube Nominal Capacity in 1000’s of lbs “4” – 4000 lbs “6”...
  • Page 24: Initial Startup - Section

    ® Vogt VT Service Manual Initial Startup Initial Startup START-UP PROCEDURE Prior to start-up, the following items should be checked: Make sure all packing has been removed from the lowside unit. To do this, you must remove the upper and lower evaporator housing covers. Remove to upper casing first, then the lower. (See Figure 4-1) CAUTION !!! Make sure Lower Evaporator Housing Cover is put back on machine before power is applied.
  • Page 25 ® Vogt VT Service Manual Initial Startup Condensing unit control panel Lowside unit control panel CB1 - Lowside CB2 - Condenser Fans 10 A 15 A FIGURE 4-2 Circuit Breakers (200/230V machines) Control Circuit Power Light Selector Switch Manual Harvest Light will be “on”...
  • Page 26 ® Vogt VT Service Manual Initial Startup VT40 Compressor Discharge Service Valve Hot Gas Line Ball Valve Compressor Suction Service Valve Liquid Line Ball Valve Receiver Service Valve VT60 Compressor Discharge Service Valve Hot Gas Line Ball Valve Compressor Suction...
  • Page 27: Adding Refrigerant

    ® Vogt VT Service Manual Initial Startup Compressor Suction VT80 & VT100 Liquid line Ball Valve Service Valve Sight Glass Compressor Discharge Condenser Ball Valves Service Valve (Hot gas & liquid return) FIGURE 4-5 Service and Ball Valve Locations Adding Refrigerant / System Charging: To charge the system with cycling fans, observe sight glass during the ice making cycle.
  • Page 28: Removing Refrigerant

    VT80/VT100 – access port on liquid line ball valve VT60 – access port on receiver rota-lock valve VT40 – access port in liquid line Note: Follow all EPA regulations and guidelines when handling refrigerant. Liquid line Ball Valve VT80 &...
  • Page 29 ® Vogt VT Service Manual Initial Startup Blank...
  • Page 30: Electrical Controls - Section

    ® Vogt VT Service Manual Electrical Controls Electrical Controls CONTROLS Explanation. The VT-Series ice machine is controlled by a PLC (Programmable Logic Controller). The PLC controls the sequence of events and monitors the ice machine functions. The operational sequences of the VT-Series ice machine can be described best as a series of six different modes.
  • Page 31: Harvest Mode

    After five seconds, the “D” (thaw gas) solenoid valves open and the chopper motor starts. On split VT40’s & VT60’s, the hot gas loop valve energizes and VT80 & VT100 the suction stop valve energizes when the chopper starts and thaw gas valves open. When the suction pressure reaches the set point on the Harvest Hold (HH) pressure switch (PLC input #2 light will turn “off”), the harvest timer will begin to time.
  • Page 32: Clean Mode

    ® Vogt VT Service Manual Electrical Controls Clean Mode. The “Clean” mode is considered to be a maintenance or service function of the machine. During this mode only the water pump will run. The water pump can be stopped by simply moving the “Selector Switch” from the “Clean” to the “Off”...
  • Page 33 ® Vogt VT Service Manual Electrical Controls PLC: FXos PLC: FX PLC Inputs PLC Outputs Description Description Current Sensing Relay (CSR) for cutter motor Machine Fault Indicator Light “On” Switch & Bin control (in series) Liquid Feed Solenoid (R404A machine only)
  • Page 34 ® Vogt VT Service Manual Electrical Controls FIGURE 5-5 Standard Complete Electrical Schematic - 208/230V (Air Cooled)
  • Page 35 ® Vogt VT Service Manual Electrical Controls FIGURE 5-5A CE Rated VT100 Electrical Schematic – 200-220V / 400-440V (Water Cooled)
  • Page 36 ® Vogt VT Service Manual Electrical Controls FIGURE 5-6 Air Cooled Condenser Wiring (200-240V/400-460V)
  • Page 37: Lowside Control Panel Layout

    ® Vogt VT Service Manual Electrical Controls MITSUBISHI E-STOP MELSEC FX OS -14MR-ES Lowside Control Panel Parts 12A2117G09 Ice Bin Control CB3/CB4 12A7515E21 Control Circuit Breaker – 2 pole (3 Amp) 12A7507S07 Current Sensing Relay (cutter/chopper motor) 12A7516E23 Cutter Motor Contactor...
  • Page 38 ® Vogt VT Service Manual Electrical Controls FIGURE 5-8 Standard Condensing Unit Electrical Schematic – 208-240V (Air Cooled)
  • Page 39 ® 5-10 Vogt VT Service Manual Electrical Controls Condensing Unit Control Panel Parts 12A7516E29 VT40 Compressor Contactor, 43Amp 12A7516E30 VT60/80/100 Compressor Contactor, 72Amp 12A7518E30 Auxiliary Contact, 1 N.O./1 N.C. 12A7515E18 Lowside Circuit Breaker, 2 pole (10Amp) 12A7515E19 AC Fan motors Circuit Breaker, 2 pole (15Amp)
  • Page 40 ® Vogt VT Service Manual 5-11 Electrical Controls FIGURE 5-9 CE Rated VT100, 200-220V/400-440V Condensing Schematic (Water Cooled)
  • Page 41 ® 5-12 Vogt VT Service Manual Electrical Controls PART # DESCRIPTION PART # DESCRIPTION 12A7516E29 CONTACTOR, 3 POLE, 43A 12A7515E21 CIRCUIT BREAKER, 2 POLE 12A7516E30 CONTACTOR, 3 POLE, 72A * DS 12A2790H07 DISCONNECT HANDLE 12A7518E30 AUX CONTACT, 1 NO/1 NC...
  • Page 42: Preventive Maintenance

    For Efficient Operation. “Preventive Maintenance” simply means that you or a delegated employee makes a daily visual check of your Vogt Ice machine. Here is what to look for and why: Daily checklist: 1. Is the machine running or is the bin full 2.
  • Page 43: Preventive Maintenance Program

    ® Vogt VT Service Manual Maintenance Preventive Maintenance Program _________ _____________ ___________ Model # Serial # Date ___________________________________ Customer/Address ___________________________________ _______________ _____________ Mgr. Name Service Tech Name The following service performed and checked: Last maintenance performed (approx. date) ___/___/___ Scale condition of water tank & tubes (good - fair - poor)
  • Page 44: Air Cooled Condenser Cleaning

    ® Vogt VT Service Manual Maintenance Air-Cooled Condenser Cleaning. Visual inspection will indicate if dirt is accumulating and clogging the fin face of the condenser. A vacuum cleaner, compressed air, or a brush may be used to remove any accumulation of loose dirt from the fin section of the condenser.
  • Page 45: Chopper Gear Reducer Oil

    ® Vogt VT Service Manual Maintenance Chopper Gear Reducer Oil. The oil level for the gear reducer should be checked if there is evidence of a leak. It should be level with the plugged opening in the side of the gear housing. Use Mobile 600W cylinder oil or equal.
  • Page 46: Machine Fault Light

    ® Vogt VT Service Manual Troubleshooting Troubleshooting The VT Series ice machine is equipped with a PLC (programmable logic controller) that controls all aspects of the machines operation. One function of the PLC is to shut down the machine when a machine fault occurs.
  • Page 47: Plc

    ® Vogt VT Service Manual Troubleshooting Description Description Outputs Inputs 0 Current Sensing Relay (chopper) 0 Fault Indicator light 1 “On” Selector Switch/Bin Control 1 Liquid Feed Solenoid (R404A machines only) 2 HH Pressure Switch 2 Compressor 3 Manual Harvest (Start) Button...
  • Page 48: Machine Inoperative

    ® Vogt VT Service Manual Troubleshooting INOPERATIVE ACHINE No Electrical Power Check main electrical fused disconnect or circuit breaker. If power has been off, crankcase heater should be energized two (2) hours prior to starting. Note: If no power to the lowside unit, check 10A breaker in condensing unit electrical enclosure.
  • Page 49: Machine "Freeze-Up

    ® Vogt VT Service Manual Troubleshooting “F ACHINE REEZE-UP” The following situations may cause machine “freeze-up”: 1. Harvest hold switch is improperly set 2. Improper fan control setting 3. Low head pressure limiting available gas for defrost 4. Dirty, scratched, or dented evaporator surface 5.
  • Page 50: Additional Troubleshooting

    ® Vogt VT Service Manual Troubleshooting ADDITIONAL TROUBLESHOOTING Low Suction Pressure - Possible causes include: 1. Evaporators froze up 2. Plugged drier 3. Low refrigerant charge 4. Moisture causing freezing @ TXV 5. Low water circulation 6. Faulty TXV 7. Bad hot gas solenoid valve High Head Pressure - Possible causes include: 1.
  • Page 51 ® Vogt VT Service Manual Troubleshooting Blank...
  • Page 52: Service Operations - Section

    Service Operations RINCIPLE OF PERATION The Vogt ® VT Series line of ice making machines from Vogt ® Tube Ice ® , LLC, combines state-of-the-art technology and efficiency with a reputation for quality and reliability developed over four decades of manufacturing.
  • Page 53: Pressure Switches

    ® Vogt VT Service Manual Service Operations Pressure Switches High Pressure Safety: 12A2117H01 (Penn) / 12A2117H01CE (Danfoss – for CE machines) This switch terminates operation of machine when high compressor discharge pressure occurs. Settings : Cut-Out (“Off”) 300 PSIG (R22) / 350 PSIG (R404A). Manual Reset...
  • Page 54 ® Vogt VT Service Manual Service Operations Oil Failure Switch: 12A2117A05 (Copeland Sentronic) On compressors manufactured before March 2011. This device monitors the compressor oil pump differential pressure. If oil pressure drops below 7-9 psig for a period of two minutes, the Sentronic module will open the control circuit contact and shut the machine off.
  • Page 55 ® Vogt VT Service Manual Service Operations Bin Control (Ranco Electronic Temperature Control) With the Ranco electronic temperature control the ice must come in contact with the sensor to shut the machine off. The sensor should be installed in the bin using the standard bin thermostat mounting bracket.
  • Page 56: Plc (Programmable Logic Controller)

    ® Vogt VT Service Manual Service Operations PLC (Programmable Logic Controller). The VT-Series ice machine is controlled by a PLC (Programmable Logic Controller). The PLC controls the sequence of events and monitors the ice machine functions. The operational sequences of the VT-Series ice machine can be described best as a series of six different modes.
  • Page 57: Compressor

    Oil Pump Oil Pump Inlet Screen Crankcase Heater Oil Sightglass Oil Pressure Safety Switch FIGURE 8-6 Copeland Discus Compressor (10HP Shown) Description Refrigerant Vogt # Copeland # Compressor VT-40 (5 1/2HP) 12A2110A117 3DB3F33K0-TFC-100 R404A 12A2110A130 3DB3F33KE-TFC-100 VT-60 (7 HP) 12A2110A110...
  • Page 58 Hot gas to evaporators Suction Stop Valve Suction Line Note: Suction Stop Valve used on VT80 & VT100 only Defrost loop valve used on Split VT40 & VT60 only Inlet Pressure Regulator Valve Description Vogt # Manufacture Defrost Solenoid Valve (Hot gas valve) 1/2”...
  • Page 59: Adjusting Txv

    Adjusting TXV Inlet Pressure Regulator: This regulator valve is used on the split VT40, split VT60, VT80 and VT100. The purpose of this valve is to maintain head pressure during the harvest cycle. (Set point = 160-170 psig) Seal /Locking Adjustment Screw Clockwise –...
  • Page 60: Water Tank Parts

    Water Pump – 12A4020H03 machine) (12A4020H03CE for CE approved Float Valve Cover, Plastic – 12A2150VT02 VT60, VT80 & VT100 Ice Chute Cover, Plastic – 12A2145VT02 Water Pump Cover, Plastic – 12A2150VT01 VT40 Ice Chute Cover, Plastic – 12A2145VT04 FIGURE 8-9 Water Tank Parts...
  • Page 61: Chopper Assembly

    Bolts welded on Evaporator Housing Nuts welded on gear reducer bracket Gear reducer vent plug Description Vogt # Chopper assembly 19T2161C03 (VT60, VT80 &VT100) 19T2161C04 (VT40) Bearing, Nylon/Stainless Ball Bearings 12A2020M19 Bracket, for Gear Reducer 19T4001S0740 Gear Reducer, 5:1 12A4030R14 Motor, ½...
  • Page 62: Evaporator Housing Covers

    VT100 Upper Evaporator housing cover - 1919T4001S0762XL/19T4001S0766 VT60 / VT80 Upper Evaporator housing cover – 19T4001S0762/19T4001S0766 VT40 Upper Evaporator housing cover – 19T4001S0764/19T40001S0766 VT60 / VT80 / VT100 Lower Evaporator housing cover – 19T4001S0763 VT40 Lower Evaporator housing cover – 19T4001S0765...
  • Page 63 ® 8-12 Vogt VT Service Manual Service Operations FIGURE 8-12 Freeze Cycle Schematic Skid mounted (Package VT40 & VT60)
  • Page 64 ® Vogt VT Service Manual 8-13 Service Operations FIGURE 8-13 Harvest Cycle Schematic Skid mounted (Package VT40 & VT60)
  • Page 65 ® 8-14 Vogt VT Service Manual Service Operations FIGURE 8-14 Freeze Cycle Schematic (w/Defrost Loop Valve) Split System (VT40 & VT60)
  • Page 66 ® Vogt VT Service Manual 8-15 Service Operations FIGURE 8-15 Harvest Cycle Schematic (w/Defrost Loop Valve) Split System (VT40 & VT60)
  • Page 67 ® 8-16 Vogt VT Service Manual Service Operations FIGURE 8-16 Freeze Cycle Schematic (w/Suction Stop Valve) (VT80 & VT100)
  • Page 68 ® Vogt VT Service Manual 8-17 Service Operations FIGURE 8-17 Harvest Cycle Schematic (w/Suction Stop Valve) (VT80 & VT100)
  • Page 69: Replacement Parts List

    12A2185D02 WATER DISTRIBUTOR FOR VT60, VT80 & VT100 12A2150VT01 WATER PUMP COVER FOR VT (B-SERIES) 12A2150VT02 WATER FLOAT VALVE COVER FOR VT (B-SERIES) 12A2145VT02 ICE CHUTE COVER FOR VT60, VT80 & VT100 (B-SERIES) 12A2145VT04 ICE CHUTE COVER FOR VT40 (B-SERIES)
  • Page 70: Condensing Unit

    Req'd Description 12A4200C0305 2 or 3 R22 - EXPANSION VALVE, SPORLAN, 2 for VT40, 3 for VT60, VT80 & VT100 12A4200C0320 2 or 3 R404A - EXPANSION VALVE, SPORLAN, 2 for VT40, 3 for VT60 & VT80 R404A - EXPANSION VALVE, SPORLAN, VT100...
  • Page 71 ® 8-20 Vogt VT Service Manual Service Operations Blank...
  • Page 72 If machine is ordered with this option the power monitor can be factory set to customer specifications. The Vogt Part number for a power monitor retrofit kit is 12A7700K01.
  • Page 73 ® Vogt VT Service Manual Additional Product Information Parameters adjustment (in order of display) Active display of Line Voltage (this is the default normal display) Active display of Load Side Voltage (if connected) Voltage Set Point (VAC Flashes) The value may be adjusted by pressing the up and down arrows. This may be set to the normal operating voltage of the device being protected in one volt increments.
  • Page 74 ® Vogt VT Service Manual Additional Product Information Remote Switch Box VT Remote Switch Box (Optional) This small control panel (box) consists of Ice/Off/Clean selector switch, a Manual Harvest/Start button and two indicator lights (power & fault) and can be added to any VT machine. This panel will contain both 208/230VAC and 24VDC.
  • Page 75 ® Vogt VT Service Manual Additional Product Information FIGURE 9-2A Standard Electrical Schematic - 208/230V (With Remote Switch Box)
  • Page 76 ® Vogt VT Service Manual Additional Product Information FIGURE 9-2B CE Approved Electrical Schematic - 208/230V (With Remote Switch Box)