Page 2
NOTICE This manual is the property of the owner of this particular Vogt Tube-Ice® machine. Model #____________________ Serial #____________________. It is to be left on the premises with this machine at all times. After start-up, it should be stored in a safe place where it can be readily available when needed for future reference in maintaining troubleshooting or servicing.
Page 3
If, at any time, you encounter conditions that we have not addressed in this manual, ® we welcome you to write or call Vogt Ice, LLC and we will give your questions our immediate attention and reply. Vogt Ice ® , LLC 1000 W.
TABLE OF CONTENTS General Information - Section 1 History of Company..................... 1-1 Receipt of Your Ice Machine ................1-2 Installation Information - Section 2 Important Safety Notice..................2-1 Machine Dimension..................... 2-2 Machine Weights & Refrigerant Line Sizes............2-2 Ice Chute Cutout ....................2-3 Water Connections....................
Page 5
Maintenance - Section 6 Preventive Maintenance ..................6-1 Preventive Maintenance Program ............... 6-2 Air Cooled Condenser Cleaning ................6-3 Compressor Oil ....................6-3 Chopper Gear Reducer Oil .................. 6-4 Water Distributor ....................6-4 Troubleshooting - Section 7 Machine Fault Light .................... 7-1 Control Power Light ....................
ISTORY OF OMPANY Henry Vogt Machine Co. was founded as a small machine shop in Louisville, Kentucky in 1880. In 1938, Vogt built the first Tube-Ice ® machine and revolutionized the ice-making industry. Our first “sized-ice” machine quickly replaced the old can-ice plants, which required much hard labor and large amounts of floor space for freezing, cutting, and crushing ice by hand.
(i.e., the trucker’s Bill of Lading). Immediately make a separate written request for inspection by the freight line’s agent. Any repair work or alteration to the machine without the permission of the Vogt Ice can void the machine’s warranty. You should also notify your Vogt distributor or the factory.
® Vogt VT Service Manual Installation Instructions Installation Information Important Safety Notice. This information is intended for use by individuals possessing adequate backgrounds of electrical, refrigeration and mechanical experience. Any attempt to repair major equipment may result in personal injury and property damage. The manufacturer or seller cannot be responsible for the interpretation of this information, nor can it assume any liability in connection with its use.
Using drawing and table below, determine ice machine location so that it is centered on bin. Place ice machine on ice storage unit and bolt in place. Machine must be level front to back and side to side for proper operation. 27” (VT40) 39 1/2” (VT60, VT80 & VT100) Skid Mounted 27”...
Page 11
Installation Instructions Makeup water, water tank drain and water tank overflow are ½” FPT connections FIGURE 2-3 VT Lowside Water and Electrical Connections – Rear View Makeup Water Flow VT40 VT60 VT80 VT100 Usage - Gallons /100 lbs of Ice Flow rate –...
Wiring And Electrical Connection. WARNING Only service personnel experienced in refrigeration and qualified to work with high ® voltage electrical equipment should be allowed to install or work on the Vogt Series Ice machine. WARNING Main Power: Power for the entire ice machine will be supplied at the condensing unit.
® Vogt VT Service Manual Installation Instructions Air Cooled Condenser Wiring: Run two #14 AWG wires from the terminals T4 and T5 on the condensing unit control panel terminal block to the air cooled condenser control panel. Note: 400/460V VT-80 & VT100’s run 3 #14 AWG wires from terminals L6, L7& L8 to air cooled condenser.
® Vogt VT Service Manual Installation Instructions Power is supplied to the lowside through circuit breaker (CB1) located in the condensing unit control panel. See diagram below. CB1 supplies power to lowside unit Condensing unit control panel FIGURE 2-7 Condensing Unit Circuit Breakers (200/230V) Air Cooled Condenser Installation (VT80 &...
Page 15
® Vogt VT Service Manual Installation Instructions Must solder with 45% silver solder Liquid return from Air Cooled Condenser (7/8” line) Discharge gas to Air Cooled Condenser VT80 - 1 1/8” VT100 – 1 3/8” Teflon Seal 12A2600T01 (for 1 1/4”-12 thread fitting) Female Rota-lock Adapters: 12A2600T03 (for 1 3/4”-12 thread fitting)
VT80 & VT100 Remote Air Cooled Condenser Wiring Note: Fan control pressure switch is located in air cooled condenser control panel on VT80 & VT100’s with remote condensers. On VT40’s and VT60’s, fan control pressure switch is location on condensing unit (highside).
Page 17
12A2600T03 (for 1 3/4”-12 thread fitting) 7/8” IDS X 1 1/4”-12 Threads Rota-lock Adapter Teflon Seal Where Used Part # Description Part # VT40 VT60 12A2396A0501 1 1/8” IDS X 1 1/4”-12Thrd 12A2600T01 Hot Gas Line 12A2396A0601 1 3/8” IDS X 1 3/4”-12Thrd...
Page 18
® Vogt VT Service Manual 2-11 Installation Instructions Control Panel FIGURE 2-13 VT60 Condensing Unit Connections Control Panel FIGURE 2-14 VT40 Condensing Unit Connections...
Page 19
® 2-12 Vogt VT Service Manual Installation Instructions Storing Ice. When storing ice in a bin, make sure the bin control sensor is mounted in the bin properly. The sensor should be mounted on the right side of the bin approximately 8” –12” from the top of the bin.
® Vogt VT Service Manual Model Specifications Vogt Ice Vertical Tube Model Number Structure VT 6 B – P F 26 AC H G 00 Basic Model “VT” – Vertical Tube Nominal Capacity in 1000’s of lbs “4” – 4000 lbs “6”...
® Vogt VT Service Manual Initial Startup Initial Startup START-UP PROCEDURE Prior to start-up, the following items should be checked: Make sure all packing has been removed from the lowside unit. To do this, you must remove the upper and lower evaporator housing covers. Remove to upper casing first, then the lower. (See Figure 4-1) CAUTION !!! Make sure Lower Evaporator Housing Cover is put back on machine before power is applied.
Page 25
® Vogt VT Service Manual Initial Startup Condensing unit control panel Lowside unit control panel CB1 - Lowside CB2 - Condenser Fans 10 A 15 A FIGURE 4-2 Circuit Breakers (200/230V machines) Control Circuit Power Light Selector Switch Manual Harvest Light will be “on”...
Page 26
® Vogt VT Service Manual Initial Startup VT40 Compressor Discharge Service Valve Hot Gas Line Ball Valve Compressor Suction Service Valve Liquid Line Ball Valve Receiver Service Valve VT60 Compressor Discharge Service Valve Hot Gas Line Ball Valve Compressor Suction...
® Vogt VT Service Manual Initial Startup Compressor Suction VT80 & VT100 Liquid line Ball Valve Service Valve Sight Glass Compressor Discharge Condenser Ball Valves Service Valve (Hot gas & liquid return) FIGURE 4-5 Service and Ball Valve Locations Adding Refrigerant / System Charging: To charge the system with cycling fans, observe sight glass during the ice making cycle.
VT80/VT100 – access port on liquid line ball valve VT60 – access port on receiver rota-lock valve VT40 – access port in liquid line Note: Follow all EPA regulations and guidelines when handling refrigerant. Liquid line Ball Valve VT80 &...
Page 29
® Vogt VT Service Manual Initial Startup Blank...
® Vogt VT Service Manual Electrical Controls Electrical Controls CONTROLS Explanation. The VT-Series ice machine is controlled by a PLC (Programmable Logic Controller). The PLC controls the sequence of events and monitors the ice machine functions. The operational sequences of the VT-Series ice machine can be described best as a series of six different modes.
After five seconds, the “D” (thaw gas) solenoid valves open and the chopper motor starts. On split VT40’s & VT60’s, the hot gas loop valve energizes and VT80 & VT100 the suction stop valve energizes when the chopper starts and thaw gas valves open. When the suction pressure reaches the set point on the Harvest Hold (HH) pressure switch (PLC input #2 light will turn “off”), the harvest timer will begin to time.
® Vogt VT Service Manual Electrical Controls Clean Mode. The “Clean” mode is considered to be a maintenance or service function of the machine. During this mode only the water pump will run. The water pump can be stopped by simply moving the “Selector Switch” from the “Clean” to the “Off”...
Page 33
® Vogt VT Service Manual Electrical Controls PLC: FXos PLC: FX PLC Inputs PLC Outputs Description Description Current Sensing Relay (CSR) for cutter motor Machine Fault Indicator Light “On” Switch & Bin control (in series) Liquid Feed Solenoid (R404A machine only)
Page 34
® Vogt VT Service Manual Electrical Controls FIGURE 5-5 Standard Complete Electrical Schematic - 208/230V (Air Cooled)
® Vogt VT Service Manual Electrical Controls MITSUBISHI E-STOP MELSEC FX OS -14MR-ES Lowside Control Panel Parts 12A2117G09 Ice Bin Control CB3/CB4 12A7515E21 Control Circuit Breaker – 2 pole (3 Amp) 12A7507S07 Current Sensing Relay (cutter/chopper motor) 12A7516E23 Cutter Motor Contactor...
Page 38
® Vogt VT Service Manual Electrical Controls FIGURE 5-8 Standard Condensing Unit Electrical Schematic – 208-240V (Air Cooled)
Page 39
® 5-10 Vogt VT Service Manual Electrical Controls Condensing Unit Control Panel Parts 12A7516E29 VT40 Compressor Contactor, 43Amp 12A7516E30 VT60/80/100 Compressor Contactor, 72Amp 12A7518E30 Auxiliary Contact, 1 N.O./1 N.C. 12A7515E18 Lowside Circuit Breaker, 2 pole (10Amp) 12A7515E19 AC Fan motors Circuit Breaker, 2 pole (15Amp)
Page 40
® Vogt VT Service Manual 5-11 Electrical Controls FIGURE 5-9 CE Rated VT100, 200-220V/400-440V Condensing Schematic (Water Cooled)
Page 41
® 5-12 Vogt VT Service Manual Electrical Controls PART # DESCRIPTION PART # DESCRIPTION 12A7516E29 CONTACTOR, 3 POLE, 43A 12A7515E21 CIRCUIT BREAKER, 2 POLE 12A7516E30 CONTACTOR, 3 POLE, 72A * DS 12A2790H07 DISCONNECT HANDLE 12A7518E30 AUX CONTACT, 1 NO/1 NC...
For Efficient Operation. “Preventive Maintenance” simply means that you or a delegated employee makes a daily visual check of your Vogt Ice machine. Here is what to look for and why: Daily checklist: 1. Is the machine running or is the bin full 2.
® Vogt VT Service Manual Maintenance Preventive Maintenance Program _________ _____________ ___________ Model # Serial # Date ___________________________________ Customer/Address ___________________________________ _______________ _____________ Mgr. Name Service Tech Name The following service performed and checked: Last maintenance performed (approx. date) ___/___/___ Scale condition of water tank & tubes (good - fair - poor)
® Vogt VT Service Manual Maintenance Air-Cooled Condenser Cleaning. Visual inspection will indicate if dirt is accumulating and clogging the fin face of the condenser. A vacuum cleaner, compressed air, or a brush may be used to remove any accumulation of loose dirt from the fin section of the condenser.
® Vogt VT Service Manual Maintenance Chopper Gear Reducer Oil. The oil level for the gear reducer should be checked if there is evidence of a leak. It should be level with the plugged opening in the side of the gear housing. Use Mobile 600W cylinder oil or equal.
® Vogt VT Service Manual Troubleshooting Troubleshooting The VT Series ice machine is equipped with a PLC (programmable logic controller) that controls all aspects of the machines operation. One function of the PLC is to shut down the machine when a machine fault occurs.
® Vogt VT Service Manual Troubleshooting INOPERATIVE ACHINE No Electrical Power Check main electrical fused disconnect or circuit breaker. If power has been off, crankcase heater should be energized two (2) hours prior to starting. Note: If no power to the lowside unit, check 10A breaker in condensing unit electrical enclosure.
® Vogt VT Service Manual Troubleshooting “F ACHINE REEZE-UP” The following situations may cause machine “freeze-up”: 1. Harvest hold switch is improperly set 2. Improper fan control setting 3. Low head pressure limiting available gas for defrost 4. Dirty, scratched, or dented evaporator surface 5.
Service Operations RINCIPLE OF PERATION The Vogt ® VT Series line of ice making machines from Vogt ® Tube Ice ® , LLC, combines state-of-the-art technology and efficiency with a reputation for quality and reliability developed over four decades of manufacturing.
® Vogt VT Service Manual Service Operations Pressure Switches High Pressure Safety: 12A2117H01 (Penn) / 12A2117H01CE (Danfoss – for CE machines) This switch terminates operation of machine when high compressor discharge pressure occurs. Settings : Cut-Out (“Off”) 300 PSIG (R22) / 350 PSIG (R404A). Manual Reset...
Page 54
® Vogt VT Service Manual Service Operations Oil Failure Switch: 12A2117A05 (Copeland Sentronic) On compressors manufactured before March 2011. This device monitors the compressor oil pump differential pressure. If oil pressure drops below 7-9 psig for a period of two minutes, the Sentronic module will open the control circuit contact and shut the machine off.
Page 55
® Vogt VT Service Manual Service Operations Bin Control (Ranco Electronic Temperature Control) With the Ranco electronic temperature control the ice must come in contact with the sensor to shut the machine off. The sensor should be installed in the bin using the standard bin thermostat mounting bracket.
® Vogt VT Service Manual Service Operations PLC (Programmable Logic Controller). The VT-Series ice machine is controlled by a PLC (Programmable Logic Controller). The PLC controls the sequence of events and monitors the ice machine functions. The operational sequences of the VT-Series ice machine can be described best as a series of six different modes.
Page 58
Hot gas to evaporators Suction Stop Valve Suction Line Note: Suction Stop Valve used on VT80 & VT100 only Defrost loop valve used on Split VT40 & VT60 only Inlet Pressure Regulator Valve Description Vogt # Manufacture Defrost Solenoid Valve (Hot gas valve) 1/2”...
Adjusting TXV Inlet Pressure Regulator: This regulator valve is used on the split VT40, split VT60, VT80 and VT100. The purpose of this valve is to maintain head pressure during the harvest cycle. (Set point = 160-170 psig) Seal /Locking Adjustment Screw Clockwise –...
12A2185D02 WATER DISTRIBUTOR FOR VT60, VT80 & VT100 12A2150VT01 WATER PUMP COVER FOR VT (B-SERIES) 12A2150VT02 WATER FLOAT VALVE COVER FOR VT (B-SERIES) 12A2145VT02 ICE CHUTE COVER FOR VT60, VT80 & VT100 (B-SERIES) 12A2145VT04 ICE CHUTE COVER FOR VT40 (B-SERIES)
Req'd Description 12A4200C0305 2 or 3 R22 - EXPANSION VALVE, SPORLAN, 2 for VT40, 3 for VT60, VT80 & VT100 12A4200C0320 2 or 3 R404A - EXPANSION VALVE, SPORLAN, 2 for VT40, 3 for VT60 & VT80 R404A - EXPANSION VALVE, SPORLAN, VT100...
Page 71
® 8-20 Vogt VT Service Manual Service Operations Blank...
Page 72
If machine is ordered with this option the power monitor can be factory set to customer specifications. The Vogt Part number for a power monitor retrofit kit is 12A7700K01.
Page 73
® Vogt VT Service Manual Additional Product Information Parameters adjustment (in order of display) Active display of Line Voltage (this is the default normal display) Active display of Load Side Voltage (if connected) Voltage Set Point (VAC Flashes) The value may be adjusted by pressing the up and down arrows. This may be set to the normal operating voltage of the device being protected in one volt increments.
Page 74
® Vogt VT Service Manual Additional Product Information Remote Switch Box VT Remote Switch Box (Optional) This small control panel (box) consists of Ice/Off/Clean selector switch, a Manual Harvest/Start button and two indicator lights (power & fault) and can be added to any VT machine. This panel will contain both 208/230VAC and 24VDC.
Page 75
® Vogt VT Service Manual Additional Product Information FIGURE 9-2A Standard Electrical Schematic - 208/230V (With Remote Switch Box)
Page 76
® Vogt VT Service Manual Additional Product Information FIGURE 9-2B CE Approved Electrical Schematic - 208/230V (With Remote Switch Box)