The vacuum pump may only be used as contractually agreed with maximum volume in the 6 o’clock position. As the impeller continues Busch. The conveyed medium, the operating liquid and the tempera- to rotate, the liquid ring moves closer to the impeller hub, the volume...
VCI-products may attack the surfaces of plastics and elastomers. Seek Transport without Packaging advice from your local packaging dealer! Busch uses CORTEC VCI 126 R film for the overseas packaging of large equipment. In case the vacuum pump is packed in a cardboard box with inflated cushions: ●...
– – dry, control the level in the operating liquid separator and if appropri- ate, cool the operating liquid to a temperature at which no cavita- – dust free and tion will occur – vibration free. Operating the vacuum pump close to its ultimate pressure requires For commissioning after conservation: large quantities of cool operating liquid.
Version with top liquid separator: Version with lateral liquid separator: Version with top liquid separator: Circuit diagram: Circuit diagram: Alternative thermostatically controlled operating liquid temperature: Closed Circuit Cooling / Total Recovery This arrangement provides for total recirculation of the operating liq- uid.
Proper alignment: both pulleys / pulley packages in one plane larger line sizes in order to avoid a loss of efficiency and an overload of the vacuum pump. Seek advice from your Busch representative! In case the vacuum shall be maintained after shutdown of the vacuum pump: ◆...
The vacuum pump may only be used as contractually agreed with Busch. The conveyed medium, the operating liquid and the tempera- ● “Bump” the drive motor ture ranges thereof may not be changed without written consent of ●...
In case of use of ring liquids other than water confirmation of the uum limitation rather than cooling. vacuum pump’s conveying characteristics shall be sought from Busch. Removing Contaminations and Deposits If liquids get conveyed together with the process gas (three to five ●...
● Mark the castings to ensure the correct reassembly and alignment the order documentation for the specified operating liquid temper- ature) ● Remove the manifold or crossover part (147.1, as applicable) ● Check the bearing temperature ● Remove the bearing caps (360.0, 360.1) (with a hand held probe or a permanent gauge, if fitted;...
If new parts are fitted the abutment ring may need to be re-machined or shimmed for pump sizes 3 to 8 (shim packs are available from Busch). For size 9 to 11 pumps, the impeller to side plate clearance is set by using bearing caps at the non drive –...
Long suction, discharge or pressure line with Use larger diameter too small diameter Internal parts are worn or damaged Repair the vacuum pump (Busch service) The gas conveyed by the vacuum pump smells Process components evaporating under vac- Check the process, if applicable...
Page 14
Try to turn the drive motor with the vacuum pump by hand If the vacuum pump is blocked: Repair the vacuum pump (Busch service) The drive motor is defective Replace the drive motor (Busch service) The vacuum pump is blocked...
Page 15
Insufficient air ventilation Make sure that the cooling of the vacuum pump is not impeded by dust/dirt Clean the fan cowling, the fan wheel, the ven- tilation grille and the cooling fins Install the vacuum pump in a narrow space only if sufficient ventilation is ensured Ambient temperature too high Observe the permitted ambient temperatures...
This Declaration of Conformity and the CE-mark affixed to the nameplate are valid for the machine within the Busch scope of delivery. This Declaration of Conformity is issued under the sole responsibility of the manufacturer. When this machine is integrated into a superordinate machinery the manufacturer of the superordinate machinery (this can be the operating company, too) must conduct the conformity assessment process for the superordinate machine or plant, issue the Declaration of Conformity for it and affix the CE-mark.
This Declaration of Conformity and the UKCA-mark affixed to the nameplate are valid for the machine within the Busch scope of delivery. This Declaration of Conformity is issued under the sole responsibility of the manufacturer. When this machine is integrated into a superordinate machinery the manufacturer of the superordinate machinery (this can be the operating company, too) must conduct the conformity assessment process for the superordinate machine or plant, issue the Declaration of Conformity for it and affix the UKCA-mark.
1450 1450 LA 0053 A LB 0063 A 1750 1750 1450 1450 LA 0103 A LB 0113 A 1750 1750 1450 1450 LA 0143 A LB 0144 A 1750 1750 1450 1450 LA 0224 A LB 0184 A 1750 1750 1450 1450 LA 0325 A...
Page 28
Busch Vacuum Solutions We shape vacuum for you. Argentina Denmark Malaysia South Africa info@busch.com.ar info@busch.dk busch@busch.com.my info@busch.co.za Australia Finland Mexico Spain sales@busch.com.au info@busch.fi info@busch.com.mx contacto@buschiberica.es Austria France Netherlands Sweden busch@busch.at busch@busch.fr info@busch.nl info@busch.se Bangladesh Germany New Zealand Switzerland sales@busch.com.bd info@busch.de sales@busch.co.nz...