12. In the FILE box, turn the small FMS knob to show the list of File choices, you will need to
load any of the following Files if the aircraft is equipped with the following optional
equipment :
a. Oxygen ‐ GEA Configuration file
b. Ice Protection (NH and FIKI) – GEA Configuration file
c. SR22 (only) Oil Temperature Sensors (2) – GEA Configuration file
13. Turn off the system.
7.6.2 GEA Testing
The following tests are recommended if the unit is removed or replaced.
1. Each GEA 71 sensor input must be checked with the aircraft engine off. Make sure all
engine information systems are valid on the MFD, and that no GEA 71 related alerts appear
on the PFD. Exercise and test all discrete, analog, and/or digital inputs and check for
appropriate responses.
2. With the STBY BATT CB pulled, check to see that the STBY BATT S current from the bottom
right corner of the EIS strip on the MFD is indicating 0.0 amps. No other maintenance is
required when the indication is 0.0. If the STBY BATT current is indicating anything other
than 0.0 amps, perform the GEA 71 Standby Battery High‐Side Current Monitor Calibration
procedure.