Garmin CIRRUS PERSPECTIVE SR20 Line Maintenance Manual page 103

Hide thumbs Also See for CIRRUS PERSPECTIVE SR20:
Table of Contents

Advertisement

____________________________________________________________________
Miscellaneous Alerts (continued) 
 
Message 
PFD CONFIG – PFD 
configuration error.  Config 
service req'd. 
 
Cirrus Perspective™ Line Maintenance Manual
190-00920-00
Cause 
The system has detected a 
PFD configuration 
mismatch. 
Solutions 
Reload PFD configuration files from 
SD Loader Card.  
Reload system configuration files 
by pressing the UPDT CFG softkey 
on the Configuration Upload Page 
in the System Page Group to load 
configuration files into the 
configuration module. 
If message persists, check config 
module wiring for faults and 
replace if necessary. 
If problem persists, replace the 
PFD. 
Page 5-57
Rev. E