Garmin CIRRUS PERSPECTIVE SR20 Line Maintenance Manual page 104

Hide thumbs Also See for CIRRUS PERSPECTIVE SR20:
Table of Contents

Advertisement

____________________________________________________________________
Miscellaneous Alerts (continued) 
 
Message 
MFD CONFIG – MFD 
configuration error.  Config 
service req'd. 
PFD VOLTAGE – PFD has low 
voltage.  Reduce power 
usage. 
MFD1 VOLTAGE – MFD1 has 
low voltage.  Reduce power 
usage. 
 
Page 5-58
Rev. E
Cause 
The system has detected a 
MFD configuration 
mismatch. 
PFD is not receiving 
sufficient voltage. 
The MFD is not receiving 
sufficient voltage. 
Solutions 
Reload MFD configuration files 
from SD Loader Card. 
Reload system configuration files 
by pressing the UPDT CFG softkey 
on the Configuration Upload Page 
in the System Page Group to load 
configuration files into the 
configuration module. 
If message persists, check config 
module wiring for faults and 
replace if necessary. 
If problem persists, replace the 
MFD. 
Check input voltage to PFD. 
If input voltage is ok, replace 
PFD. 
Check input voltage to the MFD. 
If input voltage is ok, replace 
the MFD. 
Cirrus Perspective™ Line Maintenance Manual