Advertisement

Quick Links

INDEX
1. General ................................................................................. 2
2. Safety .............................................................................. 2 - 4
A. Pump type ............................................................................ 5
B. Number of outlets ................................................................ 5
C. Revision ................................................................................ 5
D. Kinds of drive ....................................................................... 5
E. Position of drive .................................................................. 6
F. Reservoir .............................................................................. 6
G. Accessories ......................................................................... 6
3. Application ........................................................................... 7
4. Design ............................................................................. 7 - 8
5. Principle of operation .......................................................... 9
6. Specification ........................................................................ 9
7. Start-up ............................................................................... 10
8. Maintenance ............................................................... 10 - 11
9. Plates .................................................................................. 11
Page 1 of 11
Operating instructions
Pump BS-B
Page
BA_2005_5_GB_BSB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BS-B and is the answer not in the manual?

Questions and answers

Summary of Contents for Bijur Delimon BS-B

  • Page 1: Table Of Contents

    Operating instructions Pump BS-B INDEX Page 1. General ................. 2 2. Safety ................2 – 4 A. Pump type ................5 B. Number of outlets ..............5 C. Revision ................5 D. Kinds of drive ............... 5 E. Position of drive ..............6 F.
  • Page 2: General

    General Prior to start up, we recommend to read these operating instructions carefully as we do not assume any liability for damages and operating troubles which result from the nonobservance of these operating instructions! Any use beyond the applications described in these operating instructions is considered to be not in accordance with the product’s intended purposes.
  • Page 3 Safety (continuation) Personnel qualification and training The operating, maintaining, inspecting and erecting personnel must have the appropriate qualification for such work. Area of responsibility, competence and supervision of the personnel have to be regulated by the user. If the personnel do not have the necessary knowledge, they have to be trained and given instructions.
  • Page 4 Safety (continuation) Unacceptable modes of operation The operational reliability of the machine supplied is only guaranteed if the machine is used in accordance with its intended purposes as per section 1 - General - of the operating instructions. The limiting values specified in the data sheet must on no account be exceeded.
  • Page 5: Pump Type

    PUMP TYPE BSB NUMBER OF OUTLETS 1 outlet REVISION Status A KINDS OF DRIVE Flange-mounted geared motor 220 - 240 / 380 - 415 / 50 Hz, 0.75 kw, 88 min ; dimension A = 640 mm Flange-mounted geared motor 290 - 305 / 500 - 525 / 50 Hz, 0.75 kw, 88 min ;...
  • Page 6: Position Of Drive

    POSITION OF DRIVE without RESERVOIR 60 and 100 litres ACCESSORIES Level switch A level switch is available for the indication of the filling level in the reservoir. As sensor serves an ultrasonic sensor. As soon as the min. or max. level allowed has been obtained, a signal is released. With the help of a signal lamp at the reservoir, this signal can be used for the visual warning or for the control of an automatic filling facility.
  • Page 7: Application

    Application The pump BS-B is used in cases where a lot of lubrication points shall centrally and reliably be supplied with lubricant. In connection with ZV-B distributors, the pump is predominantly used in dual-line lubrication systems. The pump BS-B is also suitable for filling and lubrication systems.
  • Page 8 Design (continuation) Pos. 45 Anziehdrehmoment 65 + 5 Nm pos. 45 torque 65 + 5 Nm BA_2005_5_GB_BSB Page 8 of 11...
  • Page 9: Principle Of Operation

    Principle of operation Reservoir with wedge plate assy. and scraper A ratched mechanism (39-43) (section G-H) converts the oscillating motion of the rocker arm (77) (section E- F) into rotary motion of the feed worm (4) and the scraper (34) attached to it. Irrespective of the direction of drive of the motor the two parts always rotate clockwise causing the grease to be scraped off the wall of the reservoir (1) and forced into the housing (17), thus eliminating cavitation and ensuring positive priming of the pump unit.
  • Page 10: Start-Up

    Start-up Pump installation Install the pump vertically. Then connect the motor to the control panel (refer to wiring diagram). The motor may rotate in either directions, but with the view to the gearing of the transmission gear box, it is recommended that is should run clockwise.
  • Page 11: Plates

    Maintenance (continuation) Geared motor or gear When being delivered, the geared motor or the gear is ready for operation and filled with oil ARAL Degol MB 680, which is suitable for an ambient temperature range from - 10 C to - 20 C.