Checking And Tightening Screw Connections; Grease Counter-Bearing - Bosch Rexroth MOBILEX GFT-W 30 Series Operating Instructions Manual

Winch drives for mobile and stationary applications
Table of Contents

Advertisement

10.2.5 Checking and tightening screw connections

Check, as specified in the maintenance plan, that all screw connections are
tightly secured. Especially check:
the gearbox mounting screws
the screw plugs of bores 5, 6 and 7
the motor fixing screws
Tighten the screws of the planetary gearbox at the torque specified for the
corresponding screws in the planetary gearbox spare parts drawing in appendix
D "Technical data / Drawings" of the material number-specific operating
instructions. Observe the frame drawing of the crane or winch application
manufacturer.

10.2.6 Grease counter-bearing

Fig 5:
Counter-bearing lubricating points
11 Grease nipple
Grease the counter-bearing at the intervals specified in the maintenance
schedule. Lubricate the counter bearing via the lubricating nipple 11 on the
bearing cover / bearing housing with grease L-XBCHA3 (GB 7324 - 94) or with
FAG Arcanol MULTI3 or Klüberplex BE 31-222.
RE 79100-01-B/11.2020, MOBILEX GFT-W general operating instructions series 30, Bosch Rexroth AG
Servicing and repair
63/86