Process - Endress+Hauser Cerabar PMC11 Operating Instructions Manual

Process pressure measurement
Hide thumbs Also See for Cerabar PMC11:
Table of Contents

Advertisement

Cerabar PMC11, PMC21, PMP11, PMP21, PMP23
Endress+Hauser
12.6

Process

12.6.1
Process temperature range for devices with ceramic process
isolating diaphragm
Device
PMC11
PMC21
PMC21 for oxygen applications
• For saturated steam applications, use a device with a metal process isolating diaphragm,
or provide a siphon for temperature isolation when installing.
• Pay attention to the process temperature range of the seal. See also the following table.
Seal
Notes
FKM
-
FKM
Cleaned for oxygen service
EPDM 70
-
1)
Product Configurator, order code for "Seal"
2)
Product Configurator, order code for "Service"
Applications with changes in temperature
Frequent extreme changes in temperatures can temporarily cause measuring errors.
Temperature compensation takes place after a few minutes. Internal temperature
compensation is faster the smaller the change in temperature and the longer the time
interval.
For further information please contact your local Endress+Hauser Sales Center.
12.6.2
Process temperature range for devices with metallic process
isolating diaphragm
Device
Process temperature range
PMP11
–25 to +85 °C (–13 to +185 °F)
PMP21
–40 to +100 °C (–40 to +212 °F)
PMP23
–10 to +100 °C (+14 to +212 °F)
PMP23
At +135°C (+275 °F) for a maximum of one hour (device in operation but not within
measuring specification)
Sterilization in place (SIP)
Applications with changes in temperature
Frequent extreme changes in temperatures can temporarily cause measuring errors.
Internal temperature compensation is faster the smaller the change in temperature and
the longer the time interval.
For further information please contact your local Endress+Hauser Sales Center.
Process temperature range
–25 to +85 °C (–13 to +185 °F)
–25 to +100 °C (–13 to +212 °F)
–10 to +60 °C (+14 to +140 °F)
Process temperature range
–20 to +100 °C (–4 to +212 °F)
–10 to +60 °C (+14 to +140 °F)
–25 to +100 °C (–13 to +212 °F)
Technical data
Option
1)
A
1)
2)
A
and HB
1)
J
43