Cerabar PMC11, PMC21, PMP11, PMP21, PMP23
Sensor
Device
Devices for gauge pressure measurement
4)
100 mbar (1.5 psi)
PMC21 –0.1 (–1.5)
5)
250 mbar (4 psi)
PMC21 –0.25 (–4)
6)
400 mbar (6 psi)
PMC11
PMC21
6)
1 bar (15 psi)
PMC11
PMC21
6)
2 bar (30 psi)
PMC11
PMC21
6)
4 bar (60 psi)
PMC11
PMC21
6)
6 bar (90 psi)
PMC11
PMC21
6)
10 bar (150 psi)
PMC11
PMC21
6)
16 bar (240 psi)
PMC11
PMC21
6)
25 bar (375 psi)
PMC11
PMC21
6)
40 bar (600 psi)
PMC11
PMC21
Endress+Hauser
12
Technical data
12.1
Input
12.1.1
Measured variable
Measured process variable
• PMC11: gauge pressure
• PMP11: gauge pressure
• PMC21: gauge pressure or absolute pressure
• PMP21: gauge pressure or absolute pressure
• PMP23: gauge pressure or absolute pressure
Calculated process variable
Pressure
12.1.2
Measuring range
Ceramic process isolating diaphragm
Maximum
Lowest
Sensor measuring range
calibratable
span
lower (LRL)
upper (URL)
[bar (psi)]
[bar (psi)]
[bar (psi)]
+0.1 (+1.5)
0.02 (0.3)
+0.25 (+4)
0.05 (1)
–0.4 (–6)
+0.4 (+6)
0.08 (1.2)
–1 (–15)
+1 (+15)
0.2 (3)
–1 (–15)
+2 (+30)
0.4 (0.6)
–1 (–15)
+4 (+60)
0.8 (1.2)
–1 (–15)
+6 (+90)
2.4 (36)
–1 (–15)
+10 (+150)
2 (30)
–1 (–15)
+16 (+240)
6.4 (96)
–1 (–15)
+25 (+375)
10 (150)
–1 (–15)
+40 (+600)
8 (120)
MWP
OPL
1)
[bar (psi)]
[bar (psi)]
2.7 (40.5)
4 (60)
3.3 (49.5)
5 (75)
5.3 (79.5)
8 (120)
6.7 (100.5)
10 (150)
12 (180)
18 (270)
16.7 (250.5)
25 (375)
26.7 (400.5)
40 (600)
26.7 (400.5)
40 (600)
40 (600)
60 (900)
40 (600)
60 (900)
40 (600)
60 (900)
Technical data
2)
Factory settings
0 to 100 mbar (0 to 1.5 psi)
0 to 250 mbar (0 to 4 psi)
0 to 400 mbar (0 to 6 psi)
0 to 1 bar (0 to 15 psi)
0 to 2 bar (0 to 30 psi)
0 to 4 bar (0 to 60 psi)
0 to 6 bar (0 to 90 psi)
0 to 10 bar (0 to 150 psi)
0 to 16 bar (0 to 240 psi)
0 to 25 bar (0 to 375 psi)
0 to 40 bar (0 to 600 psi)
3)
Option
1C
1E
1F
1H
1K
1M
1N
1P
1Q
1R
1S
31