3. OUTPUT FUNCTION PARAMETERS

3-00
Frequency detection(Level)
Setting range
When output frequency of inverter meets a random appointed frequency value, multifunction external terminal
contactor shall be "Closed" if this terminal is set to d9 (3-05).
3-01
Count value agreement setting
Setting range
This parameter set the count value of the internal counter of inverter, with one of outside terminals (FWD, REV,
MI3~MI5) as the trigger terminal. When the counting ends (arrives), its appointed signal output the terminal action.
3-02
Appointed count agreement setting
Setting range
Beginning from ACI, when count value reaches this parameter setting value, the multi-functional corresponding shall
act. This parameter shall be applicable when count is to end. This output signal shall be used prior to machine stop,
to make inverter run in low speed till motor stop.
When the counting value reaches the setting value of 3-01 from ACI, give it one counting pulse again to make it
return to ACI to restart counting. So the setting value of 3-02 must be less than 3-01. When the setting value of 3-02
is more than 3-01, the corresponding multifunction terminals, if any, will not act.
Display value
C0000
0-04=1
External count
triggering signal
(Output signal)
Terminal [RA-RB-RC]
Multi function output
Function 3-05=15
terminal
Appointed count agreement
Terminal [RA-RB-RC] Function 3-05=14
Set counting
value reach
3-03
Fwd run reference delay setting
Setting range
3-04
Rev run reference delay setting
Setting range
When 3-05 is set as d17, d18 and d19, above two parameters match with it to use.
Terminal[RA/B/C] Function(Relay output)
3-05
Normally Open Contactor(RA-RC)
Normally Closed Contactor(RB-RC)
Setting range
d 1.0<->d 400Hz
d 0<->d 999
d 0<->d 999
C0003
C0001
C0002
Appointed count agreement
d 0.0<->d 60.0s
d 0.0<-> d 60.0s
d 0<->d 19
C0004
C0005
C0000
3-02=3
3-01=5
Set counting value reach
43
Factory setting
Unit
Factory setting
Unit
Factory setting
Unit
20msec
C0001
C0002
20msec
Width of triggering signal
Factory setting
Unit
Factory setting
Unit
Factory setting
Unit
d 1.0
0.1Hz
d 0
1
d 0
1
d 0.0
0.1s
d 0.0
0.0s
d 8
1