Slot 5 (In Out notification) IW x (master only):
Input byte Slave In counter: IW x+0 (unsigned 8):
Infinite counter when slave enters. Identifies the entry of a slave or connection setup to a
slave. A counter overflow occurs when the maximum value of 255 is reached.
For PLB slave: 0
Byte x
7
Input byte Slave Out counter: IW x+1 (unsigned 8):
Infinite counter when slave exits. Identifies exit of a slave or a connection abort to a slave. A
counter overflow occurs when the maximum value of 255 is reached.
For PLB slave: 0
Byte x+1
7
Slot 6 (IP address master) IW x (slave only):
Input byte IP address of connected master: IW x+0 (4 * unsignt8):
The IP address can be used to determine the segment in which the slave is currently
located. This position information may be useful for some applications.
For PLB master: 0
Byte x
Byte 3
IP_3
Slot 7 (Position) AD:
Output double word current position: AD x+0 (Integer32):
If the vehicles in your plant have a position measuring system, you can send the current
position from the vehicle control system to the PLB via PROFINET. The position is output in
the web interface in the Status tables (Page 102) and the log messages (Page 85) for better
diagnostics.
Double word x
Current position
Power Line Booster
Operating Instructions, 11/2019, A5E36203125A-AG
6
5
6
5
Byte 2
IP_2
4
3
4
3
Byte 1
IP_1
PROFINET/Ethernet
5.1 PROFINET IO
2
1
2
1
Byte 0
IP_0
0
0
67