RE 51150-B/07.11 | Drive modules
Ensuring safety
11
Decommissioning
11.1
Preparing for decommissioning
Provide a collecting tank that is large enough to accommodate the total hy-
f
draulic fluid volume.
The total volume of the hydraulic system comprises the volumes of the tank, the
line system, the drives, etc.
As a basic principle you should observe the related instructions for the complete
machine. Unless otherwise specified in these operating instructions, you should
complete the following steps:
Make sure that there are no hazards caused by adjacent machines.
f
Do not allow uninvolved persons to remain in the area concerned.
f
Lower the load or provide for safe foundation.
f
11.2
Decommissioning the drive module
Switch off the electric power and secure the system against re-activation
f
(short-circuit/bridge supply side).
Switch off the hydraulic pressure supply and secure it against re-activation.
f
Depressurize the accumulator on the oil side.
f
Drain the hydraulic fluid into the collecting tank provided. In this connection,
f
ensure complete draining of the lines and actuators. If necessary, carry out
bleeding measures.
Decommission the machine as described in the overall machine manual.
f
Bosch Rexroth AG
47/56
Decommissioning