www.lindab.com - Fire dampers are manufactured by MP3 Srl www.mp3-italia.it
For further information please refer to the Technical Manual.
As the manufacturer is constantly improving its products, the aesthetic or dimensional features, the technical data, the equipment and accessories indicated could be subject to variations.
l i n d a b | w e s i m p l i f y c o n s t r u c t i o n
Rectangular series 500 pa / 300 pa fire damper (17 pages)
Summary of Contents for Lindab FBC2
Page 1
Installation booklet This is a 12 page installation booklet. English FIRE DAMPER CIRCULAR SERIES FBC2 - 5 - 8 - 300 Pa Cert. N° 1812-CPR-1631 - 1812-CPR-1633 - 1812-CPR-1635 *1MUBFBC2-5-8EN-LIND* rev 20-10 *1MUBFBC2-5-8EN-LIND* www.lindab.com - Fire dampers are manufactured by MP3 Srl www.mp3-italia.it For further information please refer to the Technical Manual.
Page 2
FBC5 Mortar or plaster putty sealing FBC5 FBC2 FBC2 ve (i↔o) Model FBC2 - FBC5 - FBC8: square hole, mortar or plaster putty covered rock wool sealing Wall minimum thickness 100 mm FBC8 FBC8 Wall minimum density 550 kg/m³ FBC8...
Page 3
FBC5 FBC2 FBC2 ve (i↔o) Model FBC2 - FBC5 - FBC8: square hole, mortar or plaster putty covered rock wool sealing Wall minimum thickness 100 mm FBC8 FBC8 Wall rock wool density according to fire resistance class of the wall...
EI 90 S EI 60 S EI 30 S (300 Pa) (300 Pa) (300 Pa) (300 Pa) Model FBC2 - FBC5 - FBC8: square hole, Weichschott sealing Wall minimum thickness 100 mm FBC8 FBC8 Wall minimum density 550 kg/m³ FBC8 FBC8...
Wiring diagram for position microswitches Periodic inspection and cleaning FCU: Closed damper contact Periodic inspection shall be performed in accordance with the re- quirements of the law or by the building regulations or other local The fire damper's blade is open (the air flow is allowed) regulations.
Page 6
Installation of flexible connectors in order to balance out the The use of a reinforcing beam above the opening is recommended ventilation ducts expansion for walls made from concrete blocks, bricks or in concrete cell ele- ments. ATTENTION: the following indications must be considered For walls built with perforated elements, it is also recommended that binding only if legislation or local regulation where the fire the area of the opening be made from full elements (for example...
Page 7
The shafts walls shall have fire resistance equal or higher to the one of the fire damper. Plasterboard thickness 12,5 mm Model FBC2 - FBC5 - FBC8: square hole, mortar or plaster put- Rock wool ty sealing Horizontal U-shaped profile...
Page 8
Plasterboard arch infill, thickness 12,5 mm of the fire damper. Fire damper Adhesive gasket (supplied with the damper). Refer to the section Model FBC2 - FBC5 - FBC8: square hole, mortar or plaster put- Insulation if necessary ty sealing Rock wool, 40 kg/m³...
Page 9
Wall rock wool density according to fire resistance class of the wall Plasterboard arch infill, thickness 12,5 mm Rock wool 40 kg/m³ Plasterboard thickness 12.5 mm Type A (EN 520) FBC2/type F (EN 520) Plasterboard, thickness 12,5 mm F type (EN 520) FBC5, FBC8 Mortar or plaster putty Sealing: rock wool 40 kg/m³...
Page 10
Model FBC5: circular and square hole, mortar or plaster putty covered rock wool sealing Model FBC2: circular hole, mortar or plaster putty sealing Wall rock wool density according to fire resistance class of the wall Wall rock wool density according to fire resistance class of the wall...
Page 11
Model FBC2 - FBC5 - FBC8: square hole, Weichschott sealing When the fire damper is installed in shafts exit (technical compart- ments where continuous presence or transit of people is not forese- Rock wool panel 50 mm thick with 140 kg/m³ density.
Page 12
Model FBC2 - FBC5 - FBC8: square hole, Weichschott sealing Fire damper PROMASTOP E PASTE or HILTI CFS-S ACR type sealant PROMASTOP E PASTE or HILTI CFS-CT endothermic varnish Ventilation duct Adhesive gasket (supplied with the damper). Refer to the section Insulation if necessary Rock wool panel 50 mm thick with 140 kg/m³...
Need help?
Do you have a question about the FBC2 and is the answer not in the manual?
Questions and answers