1. After the drywall is installed and the surrounding area has been finished, remove the media plate from the unit.
2. Unwrap the tethered controller and ensure that the wire is lead through the opening for plumbing connections
(Figure 5, page 10). Position the tethered controller so that:
a) it can be easily accessed, if being used as the main controls, or
b) it is not obscured by either bricks, stone, or sheet metal to avoid obstructing the signal from the remote
control.
3. Initialize the tethered controller to the remote (see 'Operation' section, page 14).
4. Fill the unit with water:
Refill Containers - remove the pre-installed pluming cap(s), then install the refill containers (Figure 13, page 16).
During initial installation, each refill container should be refilled after the reservoir has filled to ensure the
maximum operating time. Each refill container holds 42 oz. (1.25L).
Hard Plumbed - prime each of the water reservoirs with 32 oz (1L) of water. The water level should fall between
the 'High' and 'Low' water indicators (Figure 6).
5. Install the media plate or log kit accessory (sold separately) on top. If using the log kit, connect the wire to the
outlet on the cassette to power the inner LEDs (Figure 6).
!
NOTE: If the unit is accessorized with something other than just the media plate or log set, ensure that media
used does create small particles that may fall into the unit or have a overall weight above 10 lb (4.5 kg) for the
CDFI500-PRO and 20 lb (9 kg) for the CDFI1000-PRO.
Figure 6
12
Log Kit
On/Off
Accessory
Switch
Connection
Tethered
Controller
Connection
High water
indicator
Low water
indicator
www.dimplex.com