THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.
Important Safety Advice:
When using electrical appliances, basic
precautions should be followed to reduce the risk
of fire, electric shock, and injury to persons,
including the following :
If the appliance is damaged, check
immediately with the supplier before
installation and operation.
This heater must not be used if the front glass
is damaged.
Do not use this heater in the immediate
surroundings of a bath, shower or swimming
pool
.
Do not use outdoors.
This heater must not be located immediately
above or below a fixed socket outlet or
connection box.
Do not cover - Overheating will result if the
heater is accidentally covered.
In the event of a fault unplug the heater.
Unplug the heater when not required for long
periods.
Although this heater complies with safety
standards, we do not recommend its use on
deep pile carpets or on long hair type of rugs.
Do not leave young children, the elderly, or
the infirm unsupervised in the vicinity of the
heater.
The appliance must be positioned so that the
plug is accessible.
If the supply cord is damaged it must be
replaced by the manufacturer or service agent
or similarly qualified person in order to avoid
a hazard.

Installation and Operating Instructions

Electrical
WARNING – THIS APPLIANCE MUST BE EARTHED
This heater must be used on an AC ~ supply only and the
voltage marked on the heater must correspond to the supply
voltage.
Do not switch the appliance on until properly installed. Please
read all the safety warnings and operating instructions.
General
Unpack the heater carefully and retain the packaging for pos-
sible future use, in the event of moving or returning the fire to
your supplier.
Contents of Carton.
SP4 Heater.
Wall fixing bracket.
Six fixing screws and six wall plugs.
Remote control and batteries ( 3 AAA's type).
Spare bulb.
Do not connect the heater to an electricity supply until it is
installed on a wall correctly. - see 'Installation'.
When in operation there is a 300 watt heat output from the
fuel effect, and an additional 120 watt output when the heated
glass panel is in operation.
The heater can be used remotely or manually. - see 'Opera-
tion'.
General features of remote control are:
Activate/Deactivate heated glass panel.
The illumination of fuel effect can be increased or
decreased.
Programmable timer.
Please note: Used in an environment where background noise
is very low, it may be possible to hear the motor which oper-
ates the flame effect. This is normal and should not be a cause
for concern.
08/18887/1
Issue 1
Fig. 1

Advertisement

Table of Contents
loading

Summary of Contents for Dimplex SP420

  • Page 1: Installation And Operating Instructions

    Wall Fire SP4 Model No: SP420 Dimensions (millimetres) THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE. Important Safety Advice: When using electrical appliances, basic precautions should be followed to reduce the risk of fire, electric shock, and injury to persons, including the following : •...
  • Page 2: Installation

    Installation Do not connect appliance until properly fixed to the wall and the Instruction leaflet is read fully. This model is designed to be permanently fixed to a wall at a minimum height of 300mm. The wall bracket must be fitted horizontally and the cable routed to the bottom right of the heater as in Fig 1.
  • Page 3: Manual Operation

    Manual Operation The Standby Switch (Switch 1) must be first turned ‘ON’ and the AUTO/MAN (Switch 2) switch set to ‘MANUAL’ to operate the manual controls - see Fig 6. Note : When the fire is put in Manual mode the first time the flame effect will come on indicated by the Bottom neon coming on for 3 seconds - see Fig 7.
  • Page 4: Remote Control Operation

    Remote Control Operation General The remote control consists of 5 control buttons and a LCD display with a visible area of 40x40mm. The maximum range of use for the remote control is 15metres. LCD display The LCD display shows the following functions: •...
  • Page 5: Replacing The Remote Control

    Replacing the remote control The new remote control must be set up as follows: Press switch 1 to ON . Press switch 2 to AUTO (see Fig. 6). Press switch 3 to O for more than 3 seconds until both LED’s are on (see Fig.
  • Page 6: Lamp Replacement

    Lamp Replacement WARNING – ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE REMOVING LAMPS. The front surround will need to be removed in order to change lamps. Warning -The front surround is heavy and easily damaged !. The front surround is fixed with 4 spring loaded pins and is supported at the top by the chassis.
  • Page 7: After Sales Service

    Cleaning WARNING – ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE CLEANING THE HEATER. For general cleaning use a soft clean duster – never use abrasive cleaners. The glass viewing screen should be cleaned carefully with a soft cloth. DO NOT use proprietary glass cleaners.
  • Page 8 [c] Glen Dimplex UK Limited All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex UK Limited. UK customer help line (8.00AM – 6.00PM Mon-Fri; 8.30AM-1.00PM Sat) Customer Services: Tel.