Maintenance; Remote Control Battery Replacement; Cleaning; Transducer Replacement - Dimplex CDFI500-PRO Installation And User Manual

Hide thumbs Also See for CDFI500-PRO:
Table of Contents

Advertisement

Available languages

Available languages

Maintenance

Remote Control Battery Replacement

To replace the battery:
1. Slide battery cover open on the remote control (Figure 12).
2. Install two 1.5 Volt (AAA) battery in the battery holder.
3. Close the battery cover.
Battery must be recycled or disposed of properly. Check with your
Local Authority or Retailer for recycling advice in your area.
WARNING: Disconnect power and allow element to cool before attempting any maintenance or cleaning to
reduce the risk of fire, electric shock or damage to persons.
CAUTION: If you need to move the unit ensure that all of the components that contain water have been emptied
before relocating.
!
NOTE: If you do not intend on using the unit for longer than 2 weeks, empty and drain the unit of water, and dry
all of the wet components.

Cleaning

It is required that the top cover(s), sump(s), refillable water containers(s)
(if used), and transducer(s) are cleaned with soap and water on a regular
basis, at a minimum once per month. More frequent cleaning may be
required depending on water quality.
CAUTION: Do not put plastic components in the dishwasher.
The air filters can be removed and gently rinsed with water to clean and
dried on a towel before reinstalling. Reinstall the filter so that the coarse
black side of the filter is facing the back of the unit.
Use only a damp cloth to clean the surfaces of the unit. Do not use
abrasive cleaners.

Transducer Replacement

After prolonged use, the ability for the unit to produce mist may become
reduced. If cleaning does not improve the performance of the flame
effect, replacement of the transducer may be required. This unit comes with replacement transducers. Additional
transducers may be purchased at www.dimplex.com/replacement-parts (9601210100RP).
!
NOTE: To remove the transducer, release the retaining tab in the sump and remove transducer.

Servicing

Except for installation and cleaning described in this manual, an authorized service representative should perform
any other servicing.
16
Figure 12
Battery Cover
Figure 13
Plumbing
Air
Caps
Filters
Release
Tabs
Sump
www.dimplex.com
Top Cover
Assembly
Refill Containers

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cdfi1000-pro

Table of Contents