Symptom-to-FRU Index

The Symptom-to-FRU Index lists error symptoms and
possible causes. The most likely cause is listed first.
Always begin with "General Checkout" on page 30. This
index can also be used to help you decide which FRUs to
have available when servicing a computer.
If you are unable to correct the problem using this index,
go to "Undetermined Problems" on page 49.
Notes
If you have both an error message and an
incorrect audio response, diagnose the error
message first.
Check all power supply voltages before you
replace the system board. (See "Power Systems
Checkout" on page 35.)
Beep Symptoms
Beeps symptoms are short tones or a series of short tones
separated by pauses (intervals without sound). See the
following examples.
Beep Symptom
1-1-3
CMOS write/read test in
progress or failure.
1-1-4
ROM BIOS check error.
1-2-1
Programmable interval timer
0 test in progress or failure.
1-2-2
DMA channel 0 address and
count register test in
progress or failure.
1-2-3
DMA page register
write/read in progress or
failure.
1-3-1
RAM refresh verification test
in progress or failure.
1-3-3
First 64K RAM chip or data
line failure, multi-bit.
1-4-2
Parity failure first 64K RAM.
1-4-3
Fail-safe timer failure (only
used by EISA BIOS).
FRU/Action
1. Run Setup
2. System Board
1. System Board
1. System Board
1. System Board
1. System Board
1. System Board
1. RAM Memory Board
2. System Board
1. System Board
1. System Board
41