IBM ThinkPad 365C 2625 Maintenance Manual page 213

Table of Contents

Advertisement

Symptom / Error
FRU / Action in Sequence
601, 6XX
1. Go to "Diskette Drive
(601: Diskette drive or
controller error.)
2. FDD assembly
3. Diskette
4. System board
602
1. Go to "Diskette Drive
(Diskette read error.)
2. Diskette
3. FDD assembly
604
1. Go to "Diskette Drive
(Unacceptable ID was read
from the diskette drive.)
2. FDD assembly
3. System board
11XX
1. Serial device
1101: Serial_A test failure.
2. Communication cable
3. System board
12XX
1. System board
1201: Serial_B test failure.
17XX
1. Hard disk drive
2. System board
1701: Hard disk
controller failure.
1780, 1790: Hard disk
0 error.
1781, 1791: Hard disk
1 error.
24XX
1. System board
(2401: System board video
error.)
808X
1. PCMCIA slot
8081: PCMCIA
2. PCMCIA device
presence test failure.
3. System board
(PCMCIA revision
number also checked.)
8082: PCMCIA register
test failure.
860X
1. External mouse
(Pointing device error when
2. External keyboard
TrackPoint III is disabled.)
3. System board
8601: System bus
error–8042 mouse
interface.
8602: External mouse
error.
8603: System bus
error or mouse error.
861X
1. Reseat the keyboard
(Pointing device error when
TrackPoint III is enabled.)
2. Keyboard
3. External mouse
8611: System bus
4. System board
error–I/F between 8042
and IPDC.
8612: TrackPoint error.
8613: System board or
TrackPoint error.
ThinkPad 380, 380D, 385, 385D (2635)
Test" on page 192.
Test" on page 192.
Test" on page 192.
(Infrared)
assembly
cables.
201

Advertisement

Table of Contents
loading