IBM ThinkPad 365C 2625 Maintenance Manual page 374

Table of Contents

Advertisement

Symptom / Error
601, 6XX
(601: Diskette drive or
controller error.)
602
(Diskette read error.)
604
(Unacceptable ID was read
from the diskette drive.)
11XX
1101: Serial_A test failure.
17XX
1701: Hard disk
controller failure.
1780, 1790: Hard disk
0 error.
1781, 1791: Hard disk
1 error.
24XX
(2401: System board video
error.)
808X
8081: PCMCIA
presence test failure.
(PCMCIA revision
number also checked.)
8082: PCMCIA register
test failure.
860X
(Pointing device error when
TrackPoint III is disabled.)
8601: System bus
error.–8042 mouse
interface.
8602: External mouse
error.
8603: System bus
error or mouse error.
362
IBM Mobile Systems - ThinkPad HMM Volume 3
FRU / Action in Sequence
1. Go to "Diskette Drive
Test" on page 348.
2. Diskette drive
assembly
3. Diskette
4. System board
1. Go to "Diskette Drive
Test" on page 348.
2. Diskette
3. Diskette drive
assembly
1. Go to "Diskette Drive
Test" on page 348.
2. Diskette drive
assembly
3. System board
1. Serial device
2. Communication cable
3. System board
1. Hard disk drive
2. System board
1. System board
2. Video card
1. PCMCIA slot
assembly
2. PCMCIA device
3. System board
1. External mouse
2. External keyboard
3. System board