Symptom-to-FRU Index

The Symptom-to-FRU Index lists the symptoms and errors
and the possible causes. The most likely cause is listed
first.
Note: Perform the FRU replacement or actions in the
sequence shown in the "FRU/Action" columns. If a FRU
did not solve the problem, put the original part back in the
computer. Do not replace a nondefective FRU.
This index can also be used to help you decide which
FRUs to have available when servicing a computer.
Numeric error codes show the errors detected in POST or
system operation. In the following error codes, X can be
any number.
If no codes are available, use narrative symptoms.
If the symptom is not listed, go to "Undetermined
Problems" on page 209.
Note: For IBM devices not supported by diagnostic
codes in the ThinkPad notebook computers,
see the manual for that device.

Numeric Error Codes

Symptom / Error
10X
101: Interrupt failure.
102: Timer failure.
103: Timer interrupt
failure.
104: Protected mode
failure.
105: Last 8042
command not
accepted.
107: NMI test failure.
108: Timer bus test
failure.
109: Low meg-chip
select test.
161
(Dead battery.)
163
(Time and Date was not
set.)
ThinkPad 380, 380D, 385, 385D (2635)
FRU / Action in Sequence
1. System board
1. Go to "Checking the
Backup Battery" on
page 195.
2. Backup battery
3. System board
1. Set time and date.
2. System board