Symptom / Error
111
(I/O parity.)
158
(HDP was not set even
though the supervisor
password is set.)
159
(HDP is not set the same as
the supervisor password.)
161
(Dead battery.)
163
(Time and date were not
set.)
173
(Configuration data was
lost.)
174
(Configuration error:
Perform"Checking the
Installed Devices List" on
page 374 before changing
any FRUs.)
175, 177, 178
175: EEPROM CRC
#1 error.
177: Supervisor
password check sum
error.
178: EEPROM is not
functional.
183
(Incorrect password entered
at the supervisor password
prompt.)
184
(POP check sum error.)
360
IBM Mobile Systems - ThinkPad HMM Volume 3
FRU / Action in Sequence
1. Go to "Memory
Checkout" on
page 342.
2. Expansion Unit/Port
Replicator
3. System board
1. Set HDPs for both
hard disk drives in the
HDD bay and the
UltraBay.
1. Set correct HDPs for
both hard disk drives in
the HDD bay and the
UltraBay.
1. Go to "Checking the
Backup Battery" on
page 353.
2. Backup battery
3. System board
1. Reseat the keyboard
connector on the
video card.
2. Set time and date.
3. System board
1. Reseat the keyboard
connector on the
video card.
2. Select OK in the error
screen; then set the
time and date.
3. Backup battery
4. System board
1. Check device
configuration.
2. System board
3. Diskette drive
assembly
4. Hard disk drive
assembly
1. System board
1. Have the user
examine the
password.
1. Reset the POP
(power-on password)
in Easy-Setup.

Advertisement