30
Base
NTRIP Caster Control & Monitoring
The ProFlex Web Server provides an easy way to remote
control and monitor the Embedded NTRIP caster.
Once the Embedded NTRIP Caster firmware option has been
activated in the receiver, the Web Server shows the Embedded
NTRIP Caster option both in the Status and Configuration
menus.
On the Configuration menu, the Embedded NTRIP caster option
is split into three submenus:
• The Settings submenu allows you to control the NTRIP
caster function (ON/OFF), declare the public IP address of
the caster, specify the unique password that all NTRIP
servers will need to provide if they want to be authorized
as a recognized source of corrections for the caster, and
the maximum number of simultaneous connections
accepted per user (default: 1). The submenu also allows
you to provide all the informative data usually found in an
NTRIP source table (this information is forwarded to users
when querying the NTRIP caster).
Reference Position
Differential
Stream 1 or 2
NTRIP Server
1 or 2
Port P or Q
(IP client)
(Ethernet Port)
Internet
NTRIP Clients
(Users)
(IP clients)
NTRIP
Caster
(IP Server)
ProFlex 800
Need help?
Do you have a question about the ashtech ProFlex 800 CORS and is the answer not in the manual?