UM_2204_PL88_2206_163320
User manual for MA evaluation boards
MA2304DNS/MA2304PNS

About this document

Scope and purpose
This document describes the use and operation of the EVAL_AUDIO_MA2304xNS evaluation kit (EVK). The
MA2304xNS EVK is an evaluation and demonstration kit for MA2304DNS and MA2304PNS proprietary multilevel
amplifiers.
Intended audience
Audio amplifier design engineers.
Attention:
Please read this user manual before operating the board. When powering up the board, make
sure to follow the instructions in the "MA2304xNS start-up sequence" section.
Stuck or in need of help?
Support for Infineon's class D audio portfolio can be found quickly and easily by visiting the
Amplifier IC Forum
audio applications team that are ready to provide timely support, helping you get your designs done quickly,
reliably, and right the first time.

Safety precautions

Note:
Please note the following warning regarding hazards associated with development systems.
Table 1
Safety precautions
User Manual
www.infineon.com/merus
or by visiting community.infineon.com. The community forum features members of the
Caution: The evaluation or reference board contains parts and assemblies sensitive to
electrostatic discharge (ESD). Electrostatic control precautions are required when
installing, testing, servicing or repairing the assembly. Component damage may result
if ESD control procedures are not followed. If you are not familiar with ESD control
procedures, refer to the applicable ESD protection handbooks and guidelines.
Please read the sections "Important notice" and "Warnings" at the end of this document
1
Class D Audio
V 1.0
2022-08-26

Advertisement

Table of Contents
loading

Summary of Contents for Infineon MA2304DNS

  • Page 1: About This Document

    Please read this user manual before operating the board. When powering up the board, make sure to follow the instructions in the “MA2304xNS start-up sequence” section. Stuck or in need of help? Support for Infineon’s class D audio portfolio can be found quickly and easily by visiting the Class D Audio Amplifier IC Forum or by visiting community.infineon.com.
  • Page 2: Table Of Contents

    User manual for MA evaluation boards MA2304DNS/MA2304PNS Table of contents Table of contents About this document ........................1 Safety precautions .......................... 1 Table of contents ..........................2 Overview ..........................3 Board features and audio performance ....................3 EVK device type ............................3 Setup guide ...........................
  • Page 3: Overview

    Please refer to the MA2304xNS device datasheet for exact current figures. EVK device type The type of device – MA2304DNS/MA2304PNS – is printed on the top of the EVK, and is also stated on the serial number label on the bottom side of the EVK PCB.
  • Page 4: Setup Guide

    User manual for MA evaluation boards MA2304DNS/MA2304PNS Setup guide Setup guide The following is included in the MA2304xNS evaluation kit: 1. An EVAL_AUDIO_MA2304xNS board 2. I S interface boards: analog in, S/PDIF coax and S/PDIF optical 3. A micro USB cable 4.
  • Page 5: Evk Connections And Interfaces

    User manual for MA evaluation boards MA2304DNS/MA2304PNS Setup guide EVK connections and interfaces The MA2304xNS EVK includes the main EVAL_AUDIO_MA2304xNS board and three interface boards. 2.1.1 EVAL_AUDIO_MA2304xNS board The board features MA2304xNS silicon, digital I/O headers, enable and mute switches, speaker terminals, power supply terminal blocks and a USB port.
  • Page 6: Interface Boards

    User manual for MA evaluation boards MA2304DNS/MA2304PNS Setup guide 2.1.2 Interface boards Three interface boards are included: analog in, S/PDIF coax and S/PDIF optical. These are plugged in to the J1 digital I/O breakout header for simple evaluation. Figure 3...
  • Page 7: Evk Headers And Connectors

    User manual for MA evaluation boards MA2304DNS/MA2304PNS Setup guide 2.1.3 EVK headers and connectors The following table provides a description of each jumper, header, switch and test point. Defaults are shown in the “Comment” column. Table 3 EVK headers and connectors...
  • Page 8 User manual for MA evaluation boards MA2304DNS/MA2304PNS Setup guide Name Description Comment TP_OUT0B Direct connection to device output node OUT0B Output measurement pin TP_OUT1A Direct connection to device output node OUT1A Output measurement pin TP_OUT1B Direct connection to device output node OUT1B...
  • Page 9: Notes On The Digital I/O Breakout Header

    User manual for MA evaluation boards MA2304DNS/MA2304PNS Setup guide Notes on the digital I/O breakout header The digital I/O breakout header (J1) provides access to audio and control signals (I S and I C, respectively) as well as several MA2304xNS GPIO pins and the onboard VDD supply (3.3 or 1.8 V). The J1 header is meant for use with the interface boards, and/or external connections (external I S, MCU, etc.) for measurements and...
  • Page 10: Operating The Demonstration Board

    User manual for MA evaluation boards MA2304DNS/MA2304PNS Operating the demonstration board Operating the demonstration board Recommended operating conditions Table 6 Recommended operating conditions Parameter Minimum Nominal Maximum Unit PVDD Output peak current (BTL) Output peak current (PBTL) 12.0 Toggle switches...
  • Page 11 5. Open another explorer window and browse to the software installation folder, typically “C:\Users\[User]\Infineon\Tools\Merus-Amplifier-Tool”. Copy the .bin file from the firmware folder to the “CRP DISABLD” drive. In this example the .bin file is called “firmware.bin”, but it could have other filenames.
  • Page 12: Speaker Load

    User manual for MA evaluation boards MA2304DNS/MA2304PNS Operating the demonstration board Speaker load The demonstration board is configured as a filterless amplifier. This means that no LC filter is placed between the amplifier outputs and the load. In normal use the amplifier relies on the inherent inductance of the loudspeaker, so no extra inductance is needed.
  • Page 13: Merus™ Amplifier Tool

    Refer to the MERUS™ amplifier tool user manual for details on how to install and use this software. Figure 10 MA2304DNS GUI main window MA2304xNS start-up sequence Follow this (recommended) sequence to start the board: Make sure toggle buttons are in “off”...
  • Page 14: Measurement Methods

    Measurement methods Measurement methods Setting up a reliable measurement configuration for the MA2304DNS or the MA2304PNS takes a little more effort than for linear amplifiers, and even “regular” switching amplifiers. This is mainly because the MA2304xNS is a filterless amplifier, which means it does not require an external (usually expensive and bulky) LC filter to remove switching residuals.
  • Page 15 User manual for MA evaluation boards MA2304DNS/MA2304PNS Measurement methods Figure 12 shows an example measurement setup using an 8 Ω/22 µH load, similar to the setup shown in Figure Figure 12 Audio measurement setup example Figure 13 shows an example dynamic range measurement performed with the previous measurement setup.
  • Page 16: Schematic

    User manual for MA evaluation boards MA2304DNS/MA2304PNS Schematic Schematic Amplifier page Figure 14 Amplifier page User Manual V 1.0 2022-08-26...
  • Page 17: Mcu Page

    User manual for MA evaluation boards MA2304DNS/MA2304PNS Schematic MCU page Figure 15 MCU page User Manual V 1.0 2022-08-26...
  • Page 18: Pcb Layout

    User manual for MA evaluation boards MA2304DNS/MA2304PNS PCB layout PCB layout Figure 16 PCB layout (top composite x-ray view) Figure 17 PCB layout (top layer) User Manual V 1.0 2022-08-26...
  • Page 19 User manual for MA evaluation boards MA2304DNS/MA2304PNS PCB layout Figure 18 PCB layout (layer 1) Figure 19 PCB layout (layer 2) User Manual V 1.0 2022-08-26...
  • Page 20 User manual for MA evaluation boards MA2304DNS/MA2304PNS PCB layout Figure 20 PCB layout (bottom layer) Figure 21 PCB layout (mirrored bottom composite x-ray view) User Manual V 1.0 2022-08-26...
  • Page 21: Bill Of Materials

    User manual for MA evaluation boards MA2304DNS/MA2304PNS Bill of materials Bill of materials Table 8 Bill of materials S. no. Reference Qty. Description Manufacturer Part number C1, C2, C7, CMreset, 100 nF 25V X5R Samsung Electro- CL05A104KA5NNND CMvbat, CMvdd1, 0402...
  • Page 22 User manual for MA evaluation boards MA2304DNS/MA2304PNS Bill of materials S. no. Reference Qty. Description Manufacturer Part number JGND, JPVDD 111-2223-001 CINCH 111-2223-001 JI2C_ADD 2.54 mm V header Würth Elektronik 61300621121 JUSB 105017-0001 Molex 105017-0001 IND. 10 uH Taiyo NRS4018T100MDGJ...
  • Page 23 User manual for MA evaluation boards MA2304DNS/MA2304PNS Bill of materials S. no. Reference Qty. Description Manufacturer Part number ULDO LP5907MFX- Texas Instruments LP5907MFX-3.3/NOPB 3.3/NOPB VDD_ON, VDD_SW 61300211121 Würth Elektronik 61300211121 VDD_SEL 61300311121 Würth Elektronik 61300311121 X_12MHz ABM8G-12.000MHZ- ABRACON ABM8G-12.000MHZ-18- 18-D2Y-T...
  • Page 24: Revision History

    User manual for MA evaluation boards MA2304DNS/MA2304PNS Revision history Revision history Document Date of release Description of changes version V 1.0 2022-08-26 Initial release User Manual V 1.0 2022-08-26...
  • Page 25: Disclaimer

    For information on the types Published by only and shall in no event be regarded as a in question please contact your nearest Infineon description or warranty of a certain functionality, Technologies office. Infineon Technologies AG condition or quality of the product.

This manual is also suitable for:

Ma2304pns

Table of Contents