TROUBLESHOOTING
23-S FCH Failure Notification (Detection)
* Connection Failure, see the next page.
1. xx0x xxxx xxxx xxxx
MG
U
FCH Mounting Location
ote 1:
FLTINF (Fault Information) consists of the following:
b0-b6
01H: ETHER Controller Initial NG (If this is indicated, replace the FCH (PA-FCHA) card)
02H: ETHER Link Failure
03H: Connection Failure
b7
Kind of Circuit Card (This information is valid when b0-b6=03H: Connection Failure only)
0:
FCCH/IPTRK
1:
FGH
ote 2:
FLTINF2 (Fault Information) consists of the following:
01H: Configuration Error
02H: ETHER Controller Reset Invalid
03H: ETHER Controller Initial NG
04H: MAC Address NG
This information is valid when FLTINF=01H: ETHER Controller Initial only
*The detailed fault information for 03H indication is explained on the next page.
CHAPTER 7
Page 168
Revision 1.0
2. xxxx xxxx xxxx xxxx.........
FLTINF2
b0
b7
b6
FLTINF
FCH CKT No.
G

Figure 7-11 23-S FCH Failure Notification

NDA-24299
FLTINF2: Fault Information2 Note 2
FLTINF: Fault Information
Circuit Number of FCH (0 - 7)
FCH Mounting Location
MG: Module Group
U: Unit (0-3)
G: Group (00-23)