Dtc 30201 - Start Up; Dtc 60211 - Start Up - Yale MPB045VG Maintenance Manual

Controller diagnostics
Hide thumbs Also See for MPB045VG:
Table of Contents

Advertisement

ELECTRICAL SYSTEM
CODES

DTC 30201 - Start Up

DTC 60211 - Start Up

POSSIBLE CAUSE
A. INCORRECT START UP SEQUENCE
B. CANBUS COMMUNICATION FAULT
C. HANDLE WIRING FAULT
D. TRACTION INTERLOCK SENSOR FAULT
E. TILLER CONTROL CARD FAULT
F. FAULTY TRACTION CONTROLLER
COMPONENT OPERATIONAL CHECK
PROCEDURE OR ACTION:
1. Conduct a visual inspection of all connectors/wiring associated with the fault code.
Are any faults detected/observed?
YES: Repair/replace connector or wiring associated with faults found. Refer to the appropriate Electrical
SystemYRM .
NO: Proceed to Step 2.
2. Re-key the vehicle.
Is the code still present?
YES: Proceed to CAUSE B.
NO: Problem may be intermittent.
CAUSE A - INCORRECT START UP SEQUENCE
PROCEDURE OR ACTION:
1. The fault code may occur when the operator commands traction when traction interlock sensor is OFF or if
driving tiller arm traveled outside of tiller arm operational range. Refer to Electrical System YRM manual for
tiller arm operational range information.
Is fault caused by tiller arm operation?
YES: Clear fault.
NO: Proceed to CAUSE A.
Check the Service Manual section in Yale Axcess Online for possible updates and check pertinent Bulletins
Confidential/Proprietary - Do Not Copy or Duplicate
Please refer to the end of this procedure for supporting diagrams.
NOTE