Battery-Bdi Reset Percent; Undervoltage Cutback Range; User Undervoltage; Total Maintenance Enable - Yale MPB045VG Maintenance Manual

Controller diagnostics
Hide thumbs Also See for MPB045VG:
Table of Contents

Advertisement

ELECTRICAL SYSTEM

Battery-BDI Reset Percent

When a battery has a high BDI percentage, its float
voltage at KSI On can sometimes cause false resets.
The BDI Reset Percent parameter addresses this
problem by allowing the user to define a BDI
Percentage value above which the BDI Percentage
variable will not reset.

Undervoltage Cutback Range

Severe Undervoltage = Undervoltage point –
Undervoltage Cutback Range or Brownout voltage
(15V) whichever is higher. This parameter sets the
voltage range between the Undervoltage and Severe
Undervoltage points. A Severe Undervoltage fault will
be set if the capacitor voltage falls below either the
Severe Undervoltage point (drive current limit set to 0)
or the Brownout voltage (bridge disabled, motor
current set to 0).

User Undervoltage

Undervoltage = Either Min Voltage controller voltage
(16.8V) or User Undervoltage × Nominal Voltage,
whichever is higher. The User Undervoltage parameter
can be used to adjust the undervoltage threshold,
which is the voltage at which the controller will cut
back drive current to prevent damage to the electrical
system. The undervoltage threshold can never be
lowered below the controller's power base minimum
voltage rating.

Total Maintenance Enable

This parameter will activate BDI maintenance reminder
for truck to be serviced after certain amount of total
hours have been accumulated in the hour meters.
Check the Service Manual section in Yale Axcess Online for possible updates and check pertinent Bulletins
Confidential/Proprietary - Do Not Copy or Duplicate
General Maintenance and Diagnostic Data

Traction Maintenance Enable

This parameter will activate BDI maintenance reminder
for truck to be serviced after certain amount of Traction
hours have been accumulated in the hour meters.

Pump Maintenance Enable

This parameter will activate BDI maintenance reminder
for truck to be serviced after certain amount of Pump
hours have been accumulated in the hour meters.

Maintenance Interval

This parameter will sets the time interval at which the
truck shall receive regular maintenance.

Reset Total Maintenance

This parameter will set back to zero the maintenance
interval counter.

Reset Traction Maintenance

This parameter will set back to zero the maintenance
interval counter.

Reset Pump Maintenance

This parameter will set back to zero the maintenance
interval counter.