Mount The Standard Motor To The K4 Or K5 Short Adapter - Siemens SIMOGEAR BA 203-KS Mounting And Operating Instructions

Adapter for gearbox
Table of Contents

Advertisement

Installing
4.5 Mounting the motor
4.5.3

Mount the standard motor to the K4 or K5 short adapter

Note
Ensure that the plastic ring
The plastic ring
To prevent fretting corrosion on the feather key of the motor shaft, apply a suitable lubricant to
the contact surfaces (e.g. Castrol: Apply Optileb Paste NH1).
Note
The contact surfaces between adapter and motor must always be sealed using a suitable sealing
compound.
1505 Bolt
Figure 4-5
36
Ex-version gearboxes
Impacts can cause sparks.
Apply adhesive (medium strength, e.g. Loctite 243) to the bolts 1505.
Ex-version gearboxes
The flange-mounted motor must be sealed across the entire contact surface in order
to prevent the penetration of a potentially explosive atmosphere.
prevents fretting corrosion on the cylinder surface of the motor shaft.
Plastic ring
Shaft
Plastic ring for K4 and K5
is located in the correct position.
SIMOGEAR adapters for gearboxes - KS, K2, K3, K4, K5, KQ, KQS, K8, A, AZ
Operating Instructions, 05/2022, A5E37431501A/RS-AL
Correct
Incorrect