Current Parameter; Sending And Receiving Length And Sub-Packing Method - Ebyte E95-DTU433L 485-V8 Series User Manual

Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd
E95/E96-DTU(433Lxx-485)-V8
The higher the air speed setting, the faster the transmission rate and the shorter the transmission distance; therefore, when the
speed meets the requirements of use, it is recommended that the airspeed be as low as possible.

3.6 Current parameter

Model
E95/E96-DTU(433L20xx-485)
E95/E96-DTU(433L30xx-485)
Note: It is recommended to reserve more than 50% of the current margin when selecting the power supply, which is conducive to
the long-term stable operation of the DTU.

3.7 Sending and receiving length and sub-packing method

Model
E95/E96-DTU(433Lxx-485)-V8
Note:
1.
If the DTU's single received data is greater than the single packet capacity, the excess data will be automatically allocated to the
second transmission until the transmission is completed;
2.
The single received data of the DTU cannot be larger than the buffer capacity.
Copyright ©2012–2022,Chengdu Ebyte Electronic Technology Co.,Ltd.
2.4k
6
Transmitting Current mA
12V
24V
230
135
306
152
Cache Size
512 bytes
E95/E96-DTU(433Lxx-485)-V8 User_Manual_EN
0.3k、1.2k、2.4k、4.8k、9.6k、19.2k
Waiting Current mA
12V
20
22
Sub-packing Method
Auto sub-packing 58 bytes
24V
12
18
8