  • Page 1 E95-DTU(400F20-485)
  • Page 2: Table Of Contents

    Chapter 9 Connection diagram in actual application ..........................16 Chapter 10 Related Products ..................................16 Chapter 11 Practical application ................................17 Chapter 12 Precautions for use .................................. 17 Chapter 13 Important statement .................................18 Revision history ......................................18 About us ........................................19 Copyright ©2012–2018,Chengdu Ebyte Electronic Technology Co., Ltd...
  • Page 3: Chapter 1 Overview

    Chapter 1 Overview 1.1 Introduction E95-DTU (400F20-485) is a cost-effective wireless data transmission radio station with multiple transmission methods. It works in the (410~510MHz) frequency band (default 433MHz). The radio provides a transparent RS485 interface, adopts a plastic shell, and is mounted on a guide rail.
  • Page 4 Use USB to RS-232 or other methods to connect the computer to the digital DTU. Start two serial port debugging assistants, select the serial port baud rate to be 9600bps (default), and the check method to be 8N1 to make serial port transparent transmission; Copyright ©2012–2018,Chengdu Ebyte Electronic Technology Co., Ltd...
  • Page 5: Parts Description

    Working mode switching control RF interface SMA-K,External thread inner hole Power supply DC power input port, pressure line port RS232 RS232 interface Standard RS-232 interface Power indicator Lights up when the power is on Copyright ©2012–2018,Chengdu Ebyte Electronic Technology Co., Ltd...
  • Page 6: Installation Size

    Chapter 2 Interface Definition 2.1 Power interface description E95-DTU can be powered by 8~28V DC power supply, it is recommended to use 12V or 24V DC power supply. The wiring port adopts 3.81 wiring terminal (2 Pin) connection. Copyright ©2012–2018,Chengdu Ebyte Electronic Technology Co., Ltd...
  • Page 7: Communication Interface Description

    Chengdu Ebyte Electronic Technology Co., Ltd. E95-DTU(400F20-485) User Manual 2.2 Communication interface description E95-DTU can use 3.81 terminal block to connect with equipment through RS-485. Standard Function Description definition signal ground Anti-interference, grounding RS-485 bus A interface RS-485 A interface is connected to device A interface...
  • Page 8: Frequency Range And Channel Number

    Note: The higher the air speed setting, the faster the transmission rate and the shorter the transmission distance; therefore, when the speed meets the requirements of use, it is recommended that the airspeed be as low as possible. Copyright ©2012–2018,Chengdu Ebyte Electronic Technology Co., Ltd...
  • Page 9: Current Parameter

    If the DTU’s single received data is greater than the single packet capacity, the excess data will be automatically allocated to the second transmission until the transmission is completed; The single received data of the DTU cannot be larger than the buffer capacity. Chapter 4 Detailed function 4.1 Fixed-point transmission (hexadecimal) Copyright ©2012–2018,Chengdu Ebyte Electronic Technology Co., Ltd...
  • Page 10: Broadcast Transmission (Hexadecimal)

     Chapter 5 Operating mode E95-DTU has four working modes. When there is no demanding low power consumption requirement, it is recommended to configure the DTU to transparent transmission mode (mode 0) if normal communication is required; The default setting of the DTU at the factory is transparent transmission mode (mode 0).
  • Page 11: Transparent Transmission Mode (Mode )

    5.3 Configuration Mode(Mode 2) Type When the M0 indicator light is off and the M1 indicator light is on, the DTU is working in mode 2 Sending Can be configured wirelessly Receiving Can be configured wirelessly Copyright ©2012–2018,Chengdu Ebyte Electronic Technology Co., Ltd...
  • Page 12: Sleep Mode (Mode 3)

    In the setting mode (M0 indicator light is off, M1 indicator light is on), send a command to the C1+C1+C1 module serial port (HEX format): C1 C1 C1, The module will return the current configuration parameters, such as: C0 00 00 18 20 00. Copyright ©2012–2018,Chengdu Ebyte Electronic Technology Co., Ltd...
  • Page 13: Version Number Read

    001: The air rate is 2.4k (default) performance, and the longer the sending 010: The air speed is 4.8k 011: The air speed is 9.6k time. 100: The air speed is 19.2k Copyright ©2012–2018,Chengdu Ebyte Electronic Technology Co., Ltd...
  • Page 14: Factory Default Parameters

    6.5 Factory default parameters Model Factory default parameter value: C0 00 00 19 2E 00 DTU Model Frequency Address Channel Air Speed Baud Rate Serial Format E90-DTU(400F20-485) 433MHz 0x0000 0x2E 2.4kbps 9600 Copyright ©2012–2018,Chengdu Ebyte Electronic Technology Co., Ltd...
  • Page 15: Chapter 7 Pc Configuration Instructions

    E95-DTU(400F20-485) User Manual Chapter 7 PC configuration instructions The following figure shows the display interface of the E95-DTU (400F20-485) configuration host computer. The user can  switch to the configuration mode through the MODE button, and quickly configure and read the parameters on the host computer.
  • Page 16: Chapter 8 Programming

    Programming can only be carried out in a specific working mode (see the above table). If the programming fails, please confirm whether the working mode of the DTU is correct. 2、 If you don't need complicated programming to open the E95-DTU (400F22-485) configuration software, you can modify the relevant parameters. Copyright ©2012–2018,Chengdu Ebyte Electronic Technology Co., Ltd...
  • Page 17: Chapter 9 Connection Diagram In Actual Application

    E90-DTU L Series Intercommunication Cost-effective LoRa, Rail Type, RS485, RS232 410/441M E95-DTU(433L30-232) E90-DTU L Series Intercommunication RS232 410/510M Ultra-low price digital radio E95-DTU(400F20-232) Cost-effective LoRa, Rail Type, RS485, RS232 410.125/493.125M E95-DTU(400SL22-232) E90-DTU L Series Intercommunication Copyright ©2012–2018,Chengdu Ebyte Electronic Technology Co., Ltd...
  • Page 18: Chapter 11 Practical Application

    E90-DTU L Series Intercommunication Chapter 11 Practical application Ebyte DTU is suitable for all kinds of point-to-point and point-to-multipoint wireless data transmission systems, such as smart homes, IoT transformation, power load monitoring, distribution automation, hydrology and water regime monitoring and reporting, tap water...
  • Page 19: Chapter 13 Important Statement

    Product damage caused by this reason will not be covered by the warranty. Chapter 13 Important statement Ebyte reserves the right of final interpretation and modification of all contents in this manual. Due to the continuous improvement of product hardware and software, this manual may be changed without prior notice. The latest version of the manual shall prevail.
  • Page 20: About Us

    About us Technical support: support@cdebyte.com Documents and RF Setting download link:: https://www.cdebyte.com Thank you for using Ebyte products! Please contact us with any questions or suggestions: info@cdebyte.com ---------------------------------------------------------------------------------------------------------------------------------- Official hotline:028-61399028 Web: https://www.cdebyte.com Address: B5 Mould Park, 199# Xiqu Ave, High-tech District, Sichuan, China...