Chengdu Ebyte Electronic Technology Co.,Ltd
If the customer needs to switch the working mode, it can be controlled by the Mode button to switch between different
5
working modes (M0 indicator, M1 indicator). Hold and press the Mode button for 1 second and release it to switch the
mode once. The mode switching details are shown in the table below:
No.
Type
Transparent
Mode 0
Transmission
Mode
Mode 1
WOR Mode
Power Saving
Mode 2
Mode
Configuration
Mode 3
Mode
Note:
The DTU has a power-down save mode function (the factory default setting is transparent transmission mode), the user
needs to switch the corresponding mode according to the M1 and M0 indicators (effective immediately).
"Quick Start" uses "E95-DTU (433L20-485)" as an example, other models refer to the configuration, pay attention to the
power input of the AC equipment.
Copyright ©2012–2022,Chengdu Ebyte Electronic Technology Co.,Ltd.
M1
M0
Light
Light
Serial port open, wireless open, transparent transmission
Off
Off
(factory default mode)
Light
Light
WOR transmission mode, data packet comes with wake-up code
Off
On
Light
Light
WOR receiving mode, saving its own receiving power
On
Off
consumption, this mode cannot transmit
Light
Light
The DTU can be programmed using the configuration software
On
On