Generator with display

Advertisement

ADVANCED ENERGY 
A
START
YES
Is the "AC
ON" LED lit?
NO
Unit could have experienced
an overtemperature condition
due to high water temperature
or low flow while the system
was sitting at idle. Cycle the
circuit breaker on the unit "off"
and then "on" again.
5-2
B
Is the generator's interlock loop
being satisfied? Confirm that pin
11 on the unit's interface is
grounded.
YES
Is water temperature
5° to 27°C and flow
volume 4 gpm?
YES
Is the line cord plugged in
tightly and is the voltage
187 to 229 V, 3 φ?
YES
Complete the procedure to
return the unit to AE
customer service.
END
December 2000
NO
Once the problem
has been identified
and corrected, you
may resume your
process.