Advanced Energy RFG 5500 User Manual page 13

Generator with display

Advertisement

ADVANCED ENERGY 
PHYSICAL SPECIFICATIONS
Size
Weight
Mounting
Clearance
Connector/Cable Specifications
RF Output Connector
AC Power Input
Circuit Breaker Lockout
User Port Connector
Coolant Connectors
RF Grounding Connector
ELECTRICAL SPECIFICATIONS
Input Power Specifications
Line Voltage
Line Frequency
Line Current
Line Power
Overcurrent Protection
RF Output Specifications
Frequency
Full Rated Output Power
Output Power Range
Output Impedance
1-2
17.8 cm (H) x 48.3 cm (W) x 58.4 cm (D) (7" (H) x
19" (W) x 23" (D))
52.2 Kg (115 pounds) maximum
Rack mounting ears provided for standard 19"
instrumentation rack. Side handles are provided to
assist in lifting.
Clearance of 4" at rear of panel required for
interconnects. No additional clearance about unit for
ambient air flow is required.
Type LC Female
4.6 m (15'), 4-wire cord (SO, 8/4, 90C type, or
equivalent) with Hubbell CS8365C connector.
A bracket for holding the breaker handle in the on or
off position is included.
15-pin, subminiature-D, female
0. 5" female NPT
¼-20 ground stud located on the rear of the unit
187 to 229 V ac (nominal 208 V); 3 φ
50 to 60 Hz
23 A/φ typical at 5 kW
8300 W at full rated RF output power (AC to RF
efficiency, 60%).
40 A circuit breaker
13.56 MHz ± 0.005%
5000 W forward power minimum into a 50 Ω non-
reactive load
100 to 5000 W. RF output is less than 1 W if the
requested setpoint is 0.
50 Ω for maximum power transfer. (See Figure 1-1 for
power derating into non-50 Ω loads.)
December 2000
P/N 5706045C