LTPH-TP-1003-02, Issue 2
M
O
OUNTING
PTIONS
The HRE-206 is suitable for mounting on a desktop or on a wall. Before setting up the equipment, select a location
that will provide appropriate security.
Regardless of where the HRE-206 is mounted, ADC recommends that the frame-ground lug
(pin 27) should be connected to earth ground according to the grounding recommendations
found in Section 9 of Bellcore's GR-1089-DEC 1996. See
more information.
Desktop Mounting
The remote enclosure includes four standoffs on the bottom plate for desktop mounting. The standoffs create an
air gap between the bottom of the enclosure and the surface of the desk. This prevents overheating by providing
airflow through the enclosure. Do not block the airflow from the top or bottom of the unit.
Wall Mounting
To mount the enclosure on a wall, loosen the backplate and use it as a template for the four mounting holes as
follows:
1
Loosen the HEX security nut on the front cover
5.75"
2
Remove the four top and bottom retaining screws that hold the backplate to the chassis.
HRE-206 Lists 1 and 2
(Figure
7.75"
12.4"
Figure 5. Chassis Assembly
June 1, 2001
"Power and Grounding" on page 7
3
5) with a
/
-inch CAN wrench.
8
Installation
for
5