Summary of Contents for ARTRAY ARTCAM-036MI2-WOM Series
Page 1
August 26, 2022 Ver1.33 USB2.0 CMOS CAMERA ARTCAM-MI-WOM Series INSTRUCTION BOOKLET 0.36M pixels ARTCAM-036MI2-WOM Series 1.3M pixels ARTCAM-130MI-WOM Series 3.0M pixels ARTCAM-300MI-WOM Series 5.0M pixels ARTCAM-500MI-WOM Series 10.0M pixels ARTCAM-1000MI-WOM Series 14.0M pixels ARTCAM-1400MI-WOM Series ARTRAY CO., LTD. - 1 -...
1. Attention ■About this manual 1. Before using the camera, please read this manual thoroughly. 2. Please keep this manual reachable and always refer to the contents when needed. 3. Please contact us if the manual is lost or damaged. We will provide a replacement. 4.
Page 5
■For Safe Use Warning ●In following circumstances, please stop using the product and turn off the power immediately to prevent the risks of fires and electric shocks. If the product is defective, please contact us for repair or exchange. For your safety, please do not disassemble, modify or repair the camera on your own. Please stop using the product and turn off the power immediately when: ・...
Page 6
For more details, please refer to the following link: Hardware Warranty: http://www.artray.us/download/artray_warranty.pdf ●We do not guarantee the functions of this product or the descriptions on this manual to be completely adapted to the users’...
2. Introduction ARTCAM-MI-WOM Series is CMOS cameras for industrial use. This series adopt USB2.0 interface, so the data can be delivered to PC directly without a capture board. Cameras are equipped with on board memory which avoid data missing during transfer. We provide a variety including cased cameras, board cameras which can be easily incorporated to other equipment, and so on.
Page 8
1/2 Sub-sampling mode 1/4 Sub-sampling mode ⚫ Global Shutter(ARTCAM-036MI2-WOM series) ARTCAM-036MI2-WOM series adopts global shutter which is very suitable for machine vision. ⚫ Mirror function Mirror could be processed either on the sensors or on the viewer software (ART-Viewer). 036MI2-WOM...
When developing image processing software, a software development kit that enables you to acquire Camera image acquisition and camera control are possible with other applications is included as standard. You can also download it from the website below. http://www.artray.us/download_sdk.html 4. The Product 1) Camera 2) USB2.0 cable (Type A-B connector cable, 3m approx.)
Exposure Time=(Shutter Value×(4608+312))×0.020833 [μsec] at 48MHz 5.3. Operation clock settings Users can switch the operation clock between 48MHz / 24MHz / 12MHz with the standard viewer software or SDK. *1 48MHz is not available on ARTCAM-036MI2-WOM series. - 10 -...
7. Dimensions 7.1. C-MOUNT, CASED, USB CABLE TYPE(Small case) ARTCAM-036MI2-WOM / 036MI2-BW-WOM / 036MI2-NIR-WOM ARTCAM-130MI-WOM / 130MI-BW-WOM / 130MI-NIR-WOM ARTCAM-300MI-WOM ARTCAM-500MI-WOM / 500MI-BW-WOM / 500MI-NIR-WOM Drawing of the base without a tripod mount *The design has changed into the small case model of this outline drawing for orders after Aug, 2012.
7.2. C-MOUNT, CASED, USB CABLE TYPE (Old model case) ARTCAM-036MI2-WOM / 036MI2-BW-WOM / 036MI2-NIR-WOM ARTCAM-130MI-WOM / 130MI-BW-WOM / 130MI-NIR-WOM ARTCAM-300MI-WOM ARTCAM-500MI-WOM / 500MI-BW-WOM / 500MI-NIR-WOM ARTCAM-1000MI-WOM / 1000MI-BW-WOM ARTCAM-1400MI-WOM Drawing of the base without a tripod mount *It is an outline drawing of previous case. It is also possible to use the same case.
7.3. BOARD LENS, BOARD TYPE ARTCAM-036MI2-WOM-OP / 036MI2—BW-WOM-OP / 036MI2-NIR-WOM-OP ARTCAM-130MI-WOM-OP / 130MI-BW-WOM-OP / 130MI-NIR-WOM-OP ARTCAM-300MI-WOM-OP ARTCAM-500MI-WOM-OP / 500MI-BW-WOM-OP / 500MI-NIR-WOM-OP ARTCAM-1000MI-WOM-OP / 1000MI-BW-WOM-OP ARTCAM-1400MI-WOM-OP *Depending on different models, size and position of components in front of sensor board (condenser...) might vary. - 17 -...
AD Conversion 10.1. ARTCAM-036MI2-WOM series / 130MI-WOM series / 300MI-WOM series / 500MI-WOM series DOUT [ 9 : 0 ] *500MI-WOM :12bit 10.1.1. Standard functions (configurable in standard viewer/SDK) ・Analog gain Global gain (analog gain) can be configured with the standard viewer software or SDK.
10.2. ARTCAM-1000MI-WOM series 10.2.1. Standard functions (configurable in standard viewer/SDK) ・Analog gain Global gain (analog gain) can be configured with the standard viewer software or SDK. Setting range on standard viewer software: 0 – 127 (x0 to x1.984375) Default value on standard viewer software: 64 Analog gain = gain value * 0.015625 Example 1) when the setting value is 64: Analog gain = 64* 0.015625= x1.0...
10.3. ARTCAM-1400MI-WOM series 10.3.1. Standard functions (configurable in standard viewer/SDK) ・Analog gain Global gain (analog gain) can be configured with the standard viewer software or SDK. Setting range on standard viewer software: 0 – 127 (x0 to x1.984375) Default value on standard viewer software: 64 Analog gain = gain value * 0.015625 Example 1) when the setting value is 64: Analog gain = 64 * 0.015625= x1.0...
Optional Functions 11.1. Trigger Input ARTCAM-MI-WOM series are designed with external trigger. *External trigger function is not available on ARTCAM-1000MI-WOM and ARTCAM-1400MI-WOM series. Trigger Input Circuit Camer 3.3V FPGA Sensor TRIG PC814 R1 = 2.4kΩ R2 = 10kΩ - 28 -...
11.1.1. Trigger timing chart(ARTCAM-036MI2-WOM series) Trigger Input TRIG Signal Reset Time Exposure Time Line Line Last Line Vertical Synchronization Signal Image Transfer (USB) Input Pulse Width Above 1ms Photo Coupler Delay 1~99μs (Subject to Input Pulse Voltage) Reset Time 6 * 1H...
11.1.2. Trigger timing chart(ARTCAM-130MI-WOM/300MI-WOM series) Trigger Input TRIG Signal Reset Time Exposure Time Line Line Last Line Vertical Synchronization Signal Image Transfer (USB) Input Pulse Width Above 1ms Photo Coupler Delay 1~99μs (Subject to Input Pulse Voltage) 9 * 1H(ARTCAM-130MI series) Reset Time 18 * 1H(ARTCAM-300MI series) Exposure Time...
11.1.3. Trigger timing chart(ARTCAM-500MI-WOM series) Trigger Input TRIG Signal Reset Time Exposure Line Time Line Last Line Vertical Synchronization Signal Image Transfer (USB) Input Pulse Width Above 1ms Photo Coupler Delay 1~99μs (Subject to Input Pulse Voltage) Reset Time 8 * 1H Exposure Time Subject to Shutter Speed Settings Frame Transfer...
11.2. GPIO GPIO option is available upon request before the delivery of the ARTCAM-MI-WOM series. Pin assign Function GPIO_0 GPIO_1 GPIO_2 VCC(3.3V) Maximum output 50mA GPIO_3 GPIO_4 GPIO_5 ・Each of the six GPIO pins is pulled up to 3.3V with 1kΩ on the circuit board and is connected to the IO pins on FPGA. ・When GPIO pins are used as output pins, the FPGA output is driven at high impedance and Low level.
System Requirements 12.1. Recommended System Requirements ●Host Controller This camera is applicable to USB 2.0. ●CPU The driver of this camera is applicable to computer architecture “x86” or “amd64”. The specification of CPU effects directly the imaging process speed, therefore it is highly recommended to utilize a high-end CPU if possible.
Page 34
ARTRAY CO., LTD. Obtained ISO 9001: 2015 2018/9/17 1-17-5 Kouenjikita, Suginami-ku, Tokyo 166-0002 Japan Tel: +81-3-3389-5488 Fax: +81-3-3389-5486 Email: sales@artray.us URL: www.artray. us - 34 -...