Installation, use and maintenance TABLE OF CONTENTS MACHINE AND MANUFACTURER IDENTIFICATION CONFORMITY DECLARATION OF CONFORMITY Declaration of compatibility MACHINE DESCRIPTION HANDLING AND TRANSPORT GENERAL WARNINGS SAFETY INSTRUCTIONS FIRST AID RULES GENERAL SAFETY RULES TECHNICAL DATA OPERATING CONDITIONS ENVIRONMENTAL CONDITIONS ELECTRICAL POWER SUPPLY DUTY CYCLE INTENDED USE 10.1...
- Machine Directive 2006/42/EC - Electromagnetic Compatibility Directive 2014/30/EU The documentation is at the disposal of the competent authority following motivated request at Piusi S.p.A. or following request sent to the e-mail address: doc_tec@piusi.com. The person authorised to compile the...
Installation, use and maintenance MACHINE DESCRIPTION PUMP Submersible volumetric electric pump for AUS32 (DEF, AdBlue®). MOTOR Brush motor, DC, low tension with intermittent cycle, closed type in protec- tion class IP68 according to CEI-EN 60034-5, HANDLING AND TRANSPORT Foreword Due to the limited weight and dimensions of the pumps, special lifting equipment is not required to handle them.
THIS MANUAL IS THE PROPERTY OF Piusi S.p.A. ANY REPRODUCTION, EVEN PARTIAL, IS FORBIDDEN. This manual belongs to Piusi S.p.A., which is the sole proprietor of all rights indicated by applicable laws, including, by way of example, laws on copy- rights.
Installation, use and maintenance Unsuitable extension leads can be hazardous, in accordance with current regulations. only extension cords that are labelled for outdoor use and have a sufficient conduction path should be used outdoors. For safety reasons, we recommend that, in principle, the equipment be used only with a earth-leakage circuit breaker (max 30 mA).
2,1 / 31 30 / 1,18 50/60 0,75 3600 ATTENTION The data refers to the following operating conditions: Fluid: Water Temperature: 20° C 25 /124 /124 This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
Installation, use and maintenance OPERATING CONDITIONS ENVIRONMENTAL CONDITIONS TEMPERA- min. +12 °F / max +104 °F TURE min. -11 °C / max +40 °C RELATIVE max. 100% HUMIDITY ATTENTION The temperature limits shown apply to the pump components and must be respected to avoid possible damage or malfunction.
A range of accessories are provided optionally (resistive level sensors) ATTENTION ANY USE OUTSIDE THE ABOVE DESCRIPTION IS NOT PERMITTED BY THE MANUFACTURER 27 /124 /124 This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
Page 10
Installation, use and maintenance USE RESTRIC- It is forbidden: TIONS, UNIN- 1 - To use the pump for operations other than its intended use TENDED BUT 2 - To run the pump dry REASONABLY 3 - To use the pump in a configuration different from the one defined by the PREDICTABLE manufacturer 4 - To use the pump with performances different from the one defined in the...
AUS32 (DEF, AdBlue®) compatible and that the tank and system have been properly cleaned, rinsed, and flushed be- fore AUS32 (DEF, AdBlue®) is delivered. 29 /124 /124 This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
Installation, use and maintenance The tank in which the pump is being installed must be vented in accordance with manufacturer’s installation instructions. Follow the tank manufactur- er’s tank installation instructions. - Make sure that the tank is free from sand, dirt, and other debris. - Cable extension junctions should only be made with a safe and water- proof system.
- short-circuit protection; - dry running protection. ATTENTION During installation and periodically, provide for verification of the ground- ing circuit in compliance with current regulations. 31 /124 /124 This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
- Make sure that the residual capacity of the delivery tank is greater than the quantity you wish to transfer; - Make sure that the level of liquid in the tank where the SQUALO35 pump is located is sufficient to guarantee the suction;...
ATTENTION During installation and periodically, provide for verification of the ground- ing circuit in compliance with current regulations. 33 /124 /124 This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.
Installation, use and maintenance NOISE LEVEL Under normal operating conditions, noise emission of all models does not exceed 70 dB at a distance of 1 metre from the electric pump. PROBLEMS AND SOLUTIONS For any problems contact the authorised dealer nearest to you. PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION...
Other components, such as pipes, rubber gaskets, plastic parts and wires, parts disposal must be disposed of by companies specialising in the disposal of industrial waste. 35 /124 /124 This manual is the property of PIUSI S.p.A. Any reproduction, even partial, is forbidden.