AVAILABLE MODELS mod. 50TH HVLP Suitable for multiple sectors mod. 50TH HVLP-X Stainless steel internal passages mod. 50TH HVLP-Q Possibility of using the quick release block, AIRCOM® QRB AIRCOM - INSTRUCTION MANUAL - 2022 - v. 1.0 ®...
Page 3
50TH HVLP series 50TH HVLP series Index Instruction Manual Warnings Maintenance and cleaning Installation and start-up Technical data Troubleshooting Spare parts and components Certified quality Support Notes WARNINGS! Carefully read and follow all instructions and safety precautions before using the product.
6-8. Do not use the compressed air supply, and the acids, alkaline solutions or other cleaning liquid supply. Use only original AIRCOM agents containing sodium hydroxide, ® accessories, spare parts, and related...
50TH HVLP series INSTALLATION TECHNICAL SPECIFICATIONS Connection hole diameter: 10,2 mm. Size of pipe junctions: • Control air inlet: = ¼ gas • Atomizing air inlet: = ¼ gas • Product inlet: = ¼ gas Gun weight: 0,75 kg Gun size: see dimensioned views VIDEO TUTORIALS ►...
50TH HVLP series INSTALLATION AND STARTUP Before using a new gun or a new product, clean the gun thoroughly with an appropriate solvent. Powering should be done with dry, filtered air and regulated to constant pressure. DIRECTIONS FOR GUN OPERATION Pipe Ø...
50TH HVLP series ADJUSTMENT SEQUENCE Lock the gun to the system using the fastening bracket and orient the head towards the appropriate coverage direction. When using the -Q version, lock the system block first, and then hook the gun. Connect the atomization air, control...
50TH HVLP series TECHNICAL DATA HEAD E-I HEAD SHOTS FLOW RATE OF ATOMIZATION ø NOZZLE THE FLUID PRESSURE CONSUMPTION (g/min) (kg/cm²) (L/min) ø ø ø ø NOTES Pump pressure 0,8 ÷ 1,0 Kg/cm². Liquid used for testing: water. Ford cup viscosity 4 = 11 sec.
Page 9
50TH HVLP series TECHNICAL DATA HEAD E-A HEAD SHOTS FLOW RATE OF ATOMIZATION ø NOZZLE THE FLUID PRESSURE CONSUMPTION (g/min) (kg/cm²) (L/min) ø ø ø ø NOTES Pump pressure 0,8 ÷ 1,0 Kg/cm². Liquid used for testing: water. Ford cup viscosity 4 = 11 sec.
50TH HVLP series TROUBLESHOOTING Anomaly Problem / Solution No pressure is getting to the gun Check air system No atomization Valve part. [43] worn out Replace valve part. [43] worn out The head part. [65] or part. [90/E], the nozzle part.
Page 11
HVLP SPRAY GUNS 50TH HVLP series mod. 50TH HVLP, 50TH HVLP-X, 50TH HVLP-Q Spare parts and components aircom.it...
50TH HVLP series CERTIFIED QUALITY CERTIFICATIONS THREE-COLOR INSERT AIRCOM products certified Each gun is marked with a three-color ® according to norm EN 13 966 - 1 (VDMA- three-dimensional seal. It represents an Einheisblatt 366) therefore additional guarantee of authenticity and...
Need help?
Do you have a question about the 50TH HVLP Series and is the answer not in the manual?
Questions and answers