9 Operation

Safety instructions

If there is a chance that safe operation is no longer possible,
take the device out of operation and secure it against
unintended startup.

Hardware settings

1 LCD indicator interface
Figure 34: DIP switch on the transmitter
(not for HART devices from HW - rev. 02.00)
Located on the top of the transmitter next to the LCD indicator
interface
1
are two DIP switches
Switch 1 activates the hardware write protection.
Switch 2 supports the request of the FOUNDATION Fieldbus for
a hardware release for simulation in accordance with ITK.
For transmitters that support HART 7, switch 2 allows the
desired HART version to be set (HART 5 or HART 7).
DIP switch
1
Local write protection
2
Release of the simulation
(FOUNDATION Fieldbus only)
2
HART version
Note
Factory setting: both switches set to 'OFF'. Local write
protection deactivated and HART 5, unless explicitly ordered
HART 7 (HART version) or simulation locked (FOUNDATION
Fieldbus).
In PROFIBUS PA devices, Switch 2 must always be set to the
'OFF' position.
2 DIP switch
2
.
Function
Off: Local write protection deactivated
On: Local write protection activated
Off: Simulation deactivated
On: Simulation activated
Off: HART 5
On: HART 7

Menu navigation

2
5
Exit
1 Operating buttons for menu
navigation
2 Indication of menu designation
3 Indication of menu number
Figure 35: LCD display (example)
You can use the
or
operating buttons to browse through
the menu or select a number or character within a parameter
value.
Different functions can be assigned to the
buttons. The function
5
that is currently assigned to them is
shown on the LCD display.
Control button functions
Meaning
Exit
Exit menu
Back
Go back one submenu
Cancel
Cancel a parameter entry
Next
Select the next position for entering numerical and
alphanumeric values
Meaning
Select
Select submenu / parameter
Edit
Edit parameter
OK
Save parameter entered
Note
For detailed information on the parameterization of the device,
consult the associated operating instructions.
Menu
3
4
5
Select
4 Marking to indicate relative
position within the menu
5 Indication of the current function
assigned to the operating
buttons