LEGRAND MIDDLE ATLANTIC NEXSYS User Manual

LEGRAND MIDDLE ATLANTIC NEXSYS User Manual

Line interactive ups
Hide thumbs Also See for MIDDLE ATLANTIC NEXSYS:

Advertisement

NEXSYS
TM
Line Interactive UPS
User Manual
100-00072 Rev A
22
PA P

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MIDDLE ATLANTIC NEXSYS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for LEGRAND MIDDLE ATLANTIC NEXSYS

  • Page 1 NEXSYS Line Interactive UPS User Manual 100-00072 Rev A PA P...
  • Page 2 All other brand names or marks are used for identification purposes and are trademarks of their respective owners. All patents are protected under existing designations. Other patents pending. Legrand AV Inc. Brands: Chief | Da-Lite | Middle Atlantic Products | Projecta | Sanus | Vaddio ©2022 | Legrand AV, Inc.
  • Page 3: Table Of Contents

    Understanding the UPS Power Button ....................37 Replacing the Battery ......................... 38 Replacing the Power Cord (if Necessary) ................... 40 Troubleshooting ..........................41 Specifications ............................. 43 System Function Block Diagram......................49 Warranty ............................. 50 ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 4: Important Safety Instructions

    Do not connect appliances or devices to the UPS output sockets or terminal that would over load the UPS. Place cables in such a way that no one can step on or trip over them. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 5 Risk of electric shock. Even after the unit is disconnected from the mains (building wiring outlet); components inside the UPS system are still connected to the battery and are electrically live and dangerous. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 6 Do not open or destroy batteries. Escaping electrolyte can cause injury to the skin and eyes. It may be toxic. Only replace the fuse with the same type and amperage to avoid fire hazards. Do not disassemble the UPS system. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 7: Instructions Importantes Sur La Sécurité

    DANGEREUSE produit qui peut être d'une ampleur suffisante pour constituer un risque d'électrocution. Un avertissement vous avertit d'une situation pouvant entraîner des blessures AVERTISSEMENT graves ou la mort. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 8 Lors de l'installation de l'équipement, assurez-vous que la somme du courant de fuite de l'onduleur et des périphériques connectés ne dépasse pas 3.5 mA. Température nominale: Les unités sont considérées acceptables pour une utilisation dans un environnement ambiant maximal de 40°C (104°F). viii ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 9 Avant de toucher, vérifiez s'il n'y a pas de tension. Ne jetez pas les piles dans un feu. Les piles peuvent exploser. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 10 à ses propres frais. Les changements ou modifications non expressément approuvés par la partie responsable de la conformité pourraient annuler l'autorité de l'utilisateur à utiliser l'équipement. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 11 à une utilisation efficace des ressources naturelles. Pour plus d'informations sur les lieux de recyclage de vos équipements usagés, veuillez contacter votre mairie ou votre service de collecte des ordures ménagères. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 12: Supplied Components And Hardware

    Electric Drill and #2 Phillips Bit (if Preferred) • • WARNING Use tools with caution and follow all safety protocols. AVERTISSEMENT Utiliser des outils avec prudence et suivre tous les protocoles de sécurité. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 13: Introduction

    If you press the power button while the UPS is in Transport Mode, the following message appears for 10 seconds on the LCD. Power Button UPS PowerLock UPS OFF in 10sec ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 14: Determining Your Equipment Power Requirements

    Altitude derating power with connected loads for UPS normal operation is listed as follows: Altitude (Feet and Meters) Derating Factor 3280.84 1000 4921.26 1500 0.95 6561.68 2000 0.91 8202.1 2500 0.86 9842.52 3000 0.82 ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 15: Installing The Ups Inside Of Your Enclosure

    Soulevez uniquement par les côtés et l'arrière de l'unité et non par le avant ou ATTENTION les rails. Acceptable Lifting Points on Your UPS Slide the back of each rail slider completely off the assembly. Back of Rail Sliders ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 16 Team lift your UPS (A) and carefully slide the front of each rail slider over the back sliders until the ears on the front rail sliders are flush with the front rackrails on your enclosure. Rear Rackrails Front Rackrails ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 17 Plug the UPS power cord into a two-pole, three-wire, grounded receptacle only. Avoid using extension cords. ATTENTION Branchez l'onduleur dans une prise bipolaire, trois fils et mise à la terre uniquement. Évitez d'utiliser des rallonges. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 18: Communicating With Your Ups

    For more information about communicating with your UPS using a wired Ethernet connection or via wireless connection over the internet using the RackLink™ Network Card option, refer to the NEXSYS UPS RackLink Network Card User Manual (100-00074) at www.legrandav.com. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 19: Disabling And Enabling The Ups Emergency Power Off (Epo) Function

    The EPO connector and socket are shown in black for clarity. • For more information, see “Understanding Rear Panel Connections” on page 24. Close the contact as desired, and then insert the EPO connector into its port. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 20: Connecting The Expandable Runtime Battery Option

    For more information, see “Charging Your UPS, the First Time” on page 13. 15A UPS Model Shown INPUT BREAKER BATTERY PACK DETECTION Expandable BREAKER Runtime Battery Option Expandable Battery Main Connector Cord ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 21 BREAKER Expandable Connect Up Expandable Battery Battery Main to Four Communication Connector Cables Cords Expandable INPUT BATTERY PACK BREAKER Runtime DETECTION BREAKER Battery Options (Not Provided) INPUT BATTERY PACK BREAKER DETECTION BREAKER ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 22 Daisy-Chain Direct Power rated receptacle. Power Connecting Connecting Additional Battery Power Cord Additional Batteries Batteries IEC to IEC To appropriately rated receptacle. Battery Power Cord IEC to IEC To appropriately rated receptacle. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 23 Option Description External Battery 0 – 4 Set the number of external battery pack(s) attached to your UPS. Auto Automatically detect the number of external battery pack(s) attached to your UPS. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 24: Basic Operation And Feature Set

    Understanding Rear Panel Connections Labels on the rear panels of different UPS models correspond with the following explanations further down. 1K and 1.5K Bank Models 1K and 1.5K Outlet Models 2K Bank Models ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 25 RS-232 Communication Port: Used for direct UPS monitoring and control. USB Communication Port: Used for direct UPS monitoring and control. AC Input: The inlet is IEC14 (for 15A) or IEC20 (for 20A) based on the model you purchased. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 26 Your UPS is in Battery Mode. Your UPS has an internal fault. For more information, see “Understanding Fault Log Messages” on page 35. Your UPS detected a weak, bad, or disconnected battery. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 27 Use Up and Down buttons to scroll the status information for your UPS. Use the Cancel button to go back or clear any possible fault or warning notifications. For more information, see “Front Panel Buttons” on page 27. NOTE The status page list and corresponding sub-pages differ based on Bank or Outlet models. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 28 Last UPS Test Displays UPS last battery test result. Outlet Status Displays the status of the UPS outlet numbers 1, 2, 3, or 4 as either O (On) or X (Off). (Screen 1) ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 29 Press the Select button to enter the configuration menu. Use Up and Down buttons to scroll and the Select button to choose a configuration function. For more information, see “Front Panel Buttons” on page 27. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 30 Using Main Menu > Configuration Functions > Bank/Outlet Press the Select button to enter the bank or outlet menu. Bank Models Use Up and Down buttons to scroll. Use the Select button to choose from the following options. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 31 Set to Auto detect. Battery Replace Date Set to 1/1/2022. Next Battery Replacement Date Set to 1/1/2024. Output Voltage Set to 120V. Load Shedding Set to Enabled. Service Mode Password Set to 0000. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 32 When disabled, all bank and outlets are locked in their current state. Password Setup 0000 – 9999 Select a four-digit password from 0000 – 9999 used when accessing and modifying service mode function settings. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 33 The LCD screen shows the three most recent Warning and Fault log messages for a total of 6 messages. Use Up and Down buttons to scroll through the log messages which appear on the screen in the order shown below. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 34 (866) 977-3901. High Internal Temperature Your UPS has detected a high internal temperature, will shut down, and will not allow a manual restart until an acceptable temperature range is reached. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 35 Contact support at av.middleatlantic.techsupport@legrand.com or (866) 977- 3901. Bad Battery – PLS replace Your UPS battery requires replacement. battery Contact support at av.middleatlantic.techsupport@legrand.com or (866) 977- 3901. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 36 Displays the IP address of the RackLink Network Card. (Only available with the RackLink Network Card option.) Displays the MAC address of the RackLink Network Card. (Only available with the RackLink Network Card option.) ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 37: Understanding The Ups Power Button

    When the UPS is On, in Line Mode, and you press and hold the Power button until you hear exactly 4 beeps, and then immediately release the button, the unit perform a manual battery self-test. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 38: Replacing The Battery

    Squeeze and pull apart the battery wire connection and separate them as shown. Battery Wire Connection Use screwdriver to remove the set screw and battery cover as shown. Battery Screw Cover Slide the battery box out of the front opening. Old Battery ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 39 Use screwdriver and set screw to re-attach the battery cover. Battery Screw Cover Re-attach the battery wire connection as shown. Battery Wire Connection Use screwdriver and (4x) screws to re-attach the front panel to your UPS as shown. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 40: Replacing The Power Cord (If Necessary)

    Tout câble d'alimentation utilisé avec cet appareil doit répondre aux spécifications répertoriées dans cette rubrique. Your UPS may require a longer length or replacement power cable. When replacing the cable with Legrand or any other supplier, the following specifications are required for 1K/1.5K UPS and 2K UPS products, respectively.
  • Page 41: Troubleshooting

    UPS and the communication cable are not expandable battery. For more information, see properly connected between “Connecting the Expandable Runtime Battery the UPS and the expandable Option” on page 20. battery. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 42 “Understanding the UPS Power message appears, the UPS Button” on page 37. was above 176⁰ F (80⁰ C) for If the problem persists, contact support at more than 5 seconds. av.middleatlantic.techsupport@legrand.com (866) 977-3901. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 43: Specifications

    NOTE Specifications are subject to change without notice. General UPX-1000R-2 UPX-1500R-2 UPX-2000R-2 Model UPX-RLNK-1000R-2 UPX-RLNK-1500R-2 UPX-RLNK-2000R-2 UPX-RLNK-1000R-8 UPX-RLNK-1500R-8 UPX-RLNK-2000R-8 UPS Topology Line Interactive 1000VAC 1500VAC 2000VAC Watts 900W 1350W 1800W Power Factor ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 44 110 | 120 | 127VAC ±5% NOTE: When 110VAC is selected, the UPS is derated to 90%. Frequency 50 Hz or 60 Hz (± 0.5 Hz) (Battery Mode) Number of Outlets Outlet Type NEMA 5-15R NEMA 5-20R ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 45 Lead Acid Lead Acid Battery Recharge Time 6 – 8 hours Battery Replacement Hot Swappable Front Access Replacement Battery UPX-RPLBATT-A UPX-RPLBATT-B UPX-RPLBATT-C Model Numbers Battery Pack Voltage 36 VDC 36 VDC 48 VDC ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 46 UPX-RLNK-2000R-2 UPX-RLNK-1000R-8 UPX-RLNK-1500R-8 UPX-RLNK-2000R-8 NEXSYS UPS Manager Supports Windows® 7, 8, 10, and 11 and Windows Server 2008, 2012, 2016, and 2019, Software Windows 2008, 2012 Server Core, and Hyper-V 2008, 2012 ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 47 For more information, see “ Using Front Panel Buttons and the LED Indicators” on page and “Operating the LCD Main Menu” on page 29. Audible Alarms On Battery, Low Battery, Battery Disconnected, Fault, or Overload ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 48 Energy Star 2.0, CEC (California Energy Commission), and DOE (U.S. Department of Energy) Features UPX-1000R-2 UPX-1500R-2 UPX-2000R-2 Model UPX-RLNK-1000R-2 UPX-RLNK-1500R-2 UPX-RLNK-2000R-2 UPX-RLNK-1000R-8 UPX-RLNK-1500R-8 UPX-RLNK-2000R-8 Load Shedding Yes (Bank) Site Fault Detection Cold Start ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 49: System Function Block Diagram

    As shown in the following diagrams, the UPS is composed of a mains input, EMI/RFI filters, inverter, battery charger, DC- to-DC converter, battery, AVR TX, and UPS output. Diagram for UPS models with 2 banks of controlled outlets. Diagram for UPS models with 8 individually controlled outlets. ©2022 | Legrand AV, Inc. All rights reserved.
  • Page 50: Warranty

    Legrand | AV Headquarters 6436 City West Parkway Eden Prairie, MN, 55344, USA At Legrand AV Inc. we are always listening. Your comments are welcome. Legrand AV is an ISO 9001 and ISO 14001 Registered Company. ©2022 | Legrand AV,...