LEGRAND MIDDLE ATLANTIC NEXSYS Series User Manual

LEGRAND MIDDLE ATLANTIC NEXSYS Series User Manual

Line interactive ups
Hide thumbs Also See for MIDDLE ATLANTIC NEXSYS Series:
Table of Contents

Advertisement

Quick Links

Line Interactive UPS
User Manual
100-00072 Rev A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MIDDLE ATLANTIC NEXSYS Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for LEGRAND MIDDLE ATLANTIC NEXSYS Series

  • Page 1 Line Interactive UPS User Manual 100-00072 Rev A...
  • Page 2 All other brand names or marks are used for identification purposes and are trademarks of their respective owners. All patents are protected under existing designations. Other patents pending. Legrand AV Inc. Brands: Chief | Da-Lite | Middle Atlantic | Projecta | Sanus | Vaddio ©2024 | Legrand AV, Inc.
  • Page 3: Table Of Contents

    Using Front Panel Buttons and the LED Indicators LED Indicators Front Panel Buttons Understanding Your UPS Status Modes Understanding the UPS Power Button Viewing Status Information on the LCD Panel Understanding Status Information on Bank UPS Models ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 4 Using Main Menu, Event Log Functions Understanding Warning Log Messages Understanding Fault Log Messages Viewing Main Menu, Information Replacing the Battery Replacing the Power Cord (if Necessary) Troubleshooting Specifications System Function Block Diagram Warranty ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 5: Important Safety Instructions - En

    Risk of electric shock when remotely controlling the unit while it is being WARNING serviced. Verify that the unit is in normal operating conditions before remotely controlling it. RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT CAUTION TYPE. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 6: Instructions Importantes Sur La Sécurité - Fr

    Lors de l’installation Line Interactive UPS Expandable Runtime Battery (UPX-EXPANRUN), refer to the Line Interactive UPS Expandable Runtime Battery User Manual (100-00071). Utiliser uniquement les accessoires spécifiés par le fabricant. Lisez toutes les instructions avant d’utiliser le produit. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 7 Ne vous débarrassez pas des piles dans un incendie. Les piles peuvent ATTENTION exploser. Ne pas ouvrir ou mutiler les piles. Les matières libérées sont nocives pour la ATTENTION peau et les yeux et peuvent être toxiques. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 8: Regulatory Compliance

    Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. viii ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 9: Conformité Réglementaire

    ICES-003 Class A Notice. This Class A digital apparatus complies with Canadian ICES-003. Industrie Canada (IC) ICES-003 Avis NMB-003, Classe A. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 10: Waste Electrical And Electronic Equipment (Weee) Directive

    à une utilisation efficace des ressources naturelles. Pour plus d'informations sur les lieux de recyclage de vos équipements usagés, veuillez contacter votre mairie ou votre service de collecte des ordures ménagères. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 11: Understanding General Symbols And Terms

    The information suggests alternative methods that may not be obvious and help users understand the benefits and capabilities of the product. A tip is not essential to the basic understanding of the material. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 12: Supplied Components And Hardware

    72" (1830 mm) USB-B to USB-A RS-232 Cable C19 to 5-20P, SignalSAFE™ for Cable 2KVA units. (3x) Terminal Block Plug User Manual (Pre-installed on UPS for EPO and Dry Contacts) NOTE To order more hardware, contact support. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 13: Required Tools

    Electric Drill and #2 Phillips Bit (if Preferred) WARNING Use tools with caution and follow all safety protocols. Utiliser des outils avec prudence et suivre tous les protocoles de AVERTISSEMENT sécurité. xiii ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 14: Introduction

    Some General Specifications For more specification details, see Specifications, on page UPX-2000R-2 UPX-1000R-2 UPX-1500R-2 Model UPX-RLNK-1000R-2 UPX-RLNK-1500R-2 UPX-RLNK-2000R-2 UPX-RLNK-1000R-8 UPX-RLNK-1500R-8 UPX-RLNK-2000R-8 1000VA 1500VA 2000VA Watts 900W 1350W 1800W Power Factor ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 15: Understanding The One-Time Ups Transport Mode

    First, use the power cord (C) and plug your UPS into AC power and allow it to NOTE charge for 8 hours before providing direct backup power to connected devices. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 16: Determining Your Equipment Power Requirements

    4. Your UPS is equipped with a fan for thermal management. Place the UPS in a well-ventilated area and maintain a minimum clearance of 4” (100mm) in the front of the UPS, and 12” ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 17: Installing The Ups Inside Of Your Enclosure

    Only lift from the sides and back of the unit and not by the front or rail CAUTION sliders. Soulevez uniquement par les côtés et l'arrière de l'unité et non par le ATTENTION avant ou les rails. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 18 3. Use electric drill, #2 Phillips bit, and (8x) rackscrews (not provided) to attach the ears on the back rail sliders to the rear rackrail at your desired height inside of your enclosure. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 19 4. Team lift your UPS (A) and carefully slide the front of each rail slider over the back sliders until the ears on the front rail sliders are flush with the front rackrails on your enclosure. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 20 NOTE other large electrical equipment are typically too high for connecting to battery and surge-protected outlets. Doing so will overload and possibly damage your UPS. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 21 The circuit should not be servicing other equipment with large electrical demands. La prise doit être protégée par un fusible ou un disjoncteur. Le AVERTISSEMENT circuit ne doit pas entretenir d'autres équipements avec de grandes exigences électriques. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 22: Communicating With Your Ups

    (E), or an Ethernet connection via the network card slot if you purchased a RackLink™ Network Card option. The network card option also may be used to communicate with your UPS remotely over the Internet. Serial Connections Network Connection RS-232 Ethernet USB Type B ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 23: Disabling And Enabling The Ups Emergency Power Off (Epo) Function

    Unless otherwise noted, the location of these items are similar on all NOTE models, and minor appearance variations do not affect the procedures explained. The EPO connector and socket are shown in black for clarity. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 24: Connecting The Expandable Runtime Battery Option

    If you are adding exactly one expandable runtime battery to your UPS NOTE system, you may decide to leave the main connector port screw and plate intact on your expandable runtime battery, if desired. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 25 4. Connect the other side of the expandable battery communication cable into the port labeled EXB on the back of your UPS. Up to 4 expandable runtime battery options may be added to your UPS NOTE system and should only be connected as shown. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 26 NEXSYS Series Line Interactive UPS User Manual Connecting the Expandable Runtime Battery Option ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 27 Plug the UPS power cord into a two-pole, three-wire, grounded WARNING receptacle only. Avoid using extension cords. Branchez l'onduleur dans une prise bipolaire, trois fils et mise à AVERTISSEMENT la terre uniquement. Évitez d'utiliser des rallonges. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 28 Charging Your UPS the First Time, on page 8. Press the power button on the UPS to turn on the system. For more information, see Understanding the UPS Power Button, on page ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 29 Option Description External Battery 0 – 4 Set the number of external battery pack(s) attached to your UPS. Automatically detect the number of external battery pack(s) Auto attached to your UPS. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 30: Basic Operation And Feature Set

    Understanding Rear Panel Connections Labels on the rear panels of the following UPS models correspond with explanations further below. 1K and 1.5K Bank Models 1K and 1.5K Outlet Models 2K Bank Model ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 31: 2K Outlet Model

    1. If you haven’t done so already, your UPS (A) must first be charged for at least 8 hours before it can provide direct backup power to connected devices. For more information, see Charging ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 32: Led Indicators

    Your UPS is in AVR Mode. Orange Your UPS is in Battery Mode. Your UPS has an internal fault. For more information, Understanding Fault Log Messages, on page Your UPS detects a weak, bad, or disconnected battery. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 33: Front Panel Buttons

    AVR Mode: When your UPS input voltage is too high or low, the unit goes into this mode to properly regulate the voltage to the banks or outlets. Battery Mode: When your UPS line voltage is unacceptable and AVR mode is unable to compensate, the unit goes into battery mode. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 34: Understanding The Ups Power Button

    For more information, see Using Front Panel Buttons and the LED Indicators, on page The status page list and corresponding sub-pages differ based on Bank or NOTE Outlet models. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 35: Understanding Status Information On Bank Ups Models

    Last UPS Test Displays the UPS last battery test result. Outlet Status Displays the status of the UPS outlet numbers 1, 2, 3, or 4 as either O (On) or (Screen 1) X (Off). ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 36: Operating The Lcd Main Menu

    Using Front Panel Buttons and the LED Indicators, on page Menu Item Information Shown Configuration Displays UPS settings that can be configured by the user. Event Log Displays the 3 most recent Fault and Warning event messages. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 37: Using Main Menu, Configuration Functions

    Set the coefficient to Yes whenever you perform a battery replacement to coefficient optimize your battery runtime calculation. Setup UPS functions such as password, activating load shedding, Service Mode changing the voltage output and sensitivity, and other items. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 38: Using Main Menu, Configuration Functions, Audible Alarm

    Use Up and Down buttons to scroll and the Select button to choose from the following options. Option Description Load Bank 1 Turn Load Bank 1 On or Off. Load Bank 2 Turn Load Bank 2 On or Off. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 39: Outlet Models

    Set to 1/1/2022. Next Battery Set to 1/1/2024. Replacement Date Output Voltage Set to 120V. Load Shedding Set to Enabled. Service Mode Set to 0000. Password Battery Aging Set to 100. Coefficient ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 40: Using Main Menu, Configuration Functions, Service Mode

    When disabled, all banks and outlets are locked in their current state. Select a four-digit password from 0000 – 9999 to access Password Setup 0000 – 9999 and modify service mode function settings. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 41: Using Main Menu, Event Log Functions

    The LCD screen shows the three most current Warning and Fault log messages for a total of 6 messages. Use Up and Down buttons to scroll through the log messages which appear on the screen in the order shown. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 42: Understanding Warning Log Messages

    The UPS will still operate; however, you must reduce the load. (over current warning) Your UPS has already shut down or is about to shut down due to an UPS is overloaded. overload condition. For more information, see Troubleshooting, on page ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 43: Understanding Fault Log Messages

    If the message still appears after disconnecting all connected equipment, contact support at av.middleatlantic.techsupport@legrand.com or (866) 977-3901. An internal bus fault occurred in your UPS. Internal Bus Fault Contact support at av.middleatlantic.techsupport@legrand.com or (866) 977-3901. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 44: Viewing Main Menu, Information

    Displays the user setup name. The Device Name only appears if you have the Device Name NOTE RackLink Network Card option installed and configured correctly. UPS Model Displays the UPS model name. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 45 Network Card option installed and configured correctly. Displays the MAC address of the RackLink Network Card. The MAC address only appears if you have the NOTE RackLink Network Card option installed and configured correctly. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 46: Replacing The Battery

    1. Use a #2 Phillips screwdriver and remove the (4x) screws from the front panel of the UPS (A) as shown. 2. Remove the panel from the UPS and set it aside along with the screws for reattachment. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 47 3. Squeeze and pull apart the battery wire connection and separate the wires as shown. 4. Use screwdriver to remove the set screw and battery cover as shown. 5. Slide the battery box out of the front opening. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 48 7. Slide your new battery into the front opening. 8. Use screwdriver and set screw to reattach the battery cover. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 49 RackLink Network Card User Manual (100- 00074). 12. On the LCD screen, select Yes as the coefficient to optimize your battery runtime calculation. For more information, see Using Main Menu, Configuration Functions, on page ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 50: Replacing The Power Cord (If Necessary)

    You may require a longer length cord for your specific UPS installation or just need a replacement. When replacing the cable with one from Legrand or any other supplier, the following specifications are required for 1K/1.5K UPS and 2K UPS products, respectively.
  • Page 51: Troubleshooting

    If you are still experiencing problems after operate for the expected your UPS has been charged a full eight The battery needs to runtime duration.  hours, contact support at be replaced. av.middleatlantic.techsupport@legrand.com or (866) 977-3901. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 52 UPS. Input Current warning produces higher message. For more information, refer to the current to maintain the Manager Software User Manual (100-00077) power demand. or the RackLink Network Card User Manual (100-00074). ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 53 Temperature” warning UPS Power Button, on page message appears, the UPS was above 176⁰ F If the problem persists, contact support at (80⁰ C) for more than 5 av.middleatlantic.techsupport@legrand.com seconds. or (866) 977-3901. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 54: Specifications

    Specifications General UPX-2000R-2 UPX-1000R-2 UPX-1500R-2 Model UPX-RLNK-1000R-2 UPX-RLNK-1500R-2 UPX-RLNK-2000R-2 UPX-RLNK-1000R-8 UPX-RLNK-1500R-8 UPX-RLNK-2000R-8 Line Interactive Topology 1000VA 1500VA 2000VA Watts 900W 1350W 1800W Power Factor ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 55 90VAC min – 146VAC max Regulation Double 105VAC and 90VAC Boost Double Buck 130VAC and 146VAC Waveform (Battery Pure Sine Wave Mode) Nominal Voltage 120VAC ±5% (Battery Mode) Maximum Peak Load Rated Load ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 56 5% max @ 100% linear load, 12% max @ 100% non-linear load BTUs (Line Mode) BTUs (Battery Mode) Full-Load 4 minutes 3 minutes 3 minutes Run Time Half-Load 13 minutes 10 minutes 10 minutes Run Time ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 57 36 VDC 48 VDC Voltage Expandable Runtime Battery Option (ERB) UPX-2000R-2 UPX-1000R-2 UPX-1500R-2 Model UPX-RLNK-1000R-2 UPX-RLNK-1500R-2 UPX-RLNK-2000R-2 UPX-RLNK-1000R-8 UPX-RLNK-1500R-8 UPX-RLNK-2000R-8 Composition Lead Acid Recharge 6-8 Hours Time Battery Hot-Swappable Front Access Replacement ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 58 68 | 164 minutes 43 | 111 minutes 50 | 135 minutes Half-Load Runtimes UPS + 4 ERB Full- and 93 | 222 minutes 60 | 154 minutes 71 | 178 minutes Half-Load Runtimes ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 59 SNMP V3, HTTP, HTTPS, TLS 1.2, SSH, Imbedded Web GUI with Dashboard, Features for the RADIUS, TCP/IP, Telnet, and FTP. RackLink For more information, see Communicating with Your UPS, on page Network Card Option (If Applicable) ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 60 17.3” (440mm) x 3.4” Width x (86.5mm) x 17.3” (86.5mm) x 17.3” (86.5mm) x 23.6” Height x (440mm) (440mm) (600mm) Depth Product 44.1 lbs. (20kg) 44.1 lbs. (20kg) 63.05 lbs. (28.6kg) Weight ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 61 Energy Star 2.0, CEC (California Energy Commission), Efficiency and DOE (U.S. Department of Energy) Features UPX-2000R-2 UPX-1000R-2 UPX-1500R-2 Model UPX-RLNK-1000R-2 UPX-RLNK-1500R-2 UPX-RLNK-2000R-2 UPX-RLNK-1000R-8 UPX-RLNK-1500R-8 UPX-RLNK-2000R-8 Load Yes (Bank) Shedding Site Fault Detection Cold Start ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 62 NEXSYS Series Line Interactive UPS User Manual Specifications Warranty UPX-2000R-2 UPX-1000R-2 UPX-1500R-2 Model UPX-RLNK-1000R-2 UPX-RLNK-1500R-2 UPX-RLNK-2000R-2 UPX-RLNK-1000R-8 UPX-RLNK-1500R-8 UPX-RLNK-2000R-8 Three Years Limited (2 Years Battery) Standard For warranty information, refer to www.legrandav.com/policies/warranty_ information. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 63: System Function Block Diagram

    As shown in the following diagrams, the UPS is composed of a mains input, EMI/RFI filters, inverter, battery charger, DC-to-DC converter, battery, AVR TX, and UPS output. Diagram for UPS models with 2 banks of controlled outlets. Diagram for UPS models with 8 individually controlled outlets. ©2024 | Legrand AV, Inc. All rights reserved.
  • Page 64: Warranty

    Legrand | AV Headquarters 6436 City West Parkway Eden Prairie, MN, 55344, USA At Legrand AV Inc. we are always listening. Your comments are welcome. Legrand AV is an ISO 9001 and ISO 14001 Registered Company. ©2024 | Legrand AV,...

Table of Contents