1/3” 700tvl resolution day/night vandal dome with wdr (13 pages)
Summary of Contents for Dante DNA1990
Page 1
DNA1990-DNA1992Y IP PTZ Domes Web Operations Manual Model Number: DNA1990, DNA1990Y, DNA1992Y Description: IP MP PTZ Domes and IR PTZ Domes 20x and 30x Optical Zoom...
Table of Contents Network Connection ........................1 Preparation ........................1 Log in ..........................1 Live Interface ......................... 3 Encode Setup ........................ 3 Video Window Setup ....................4 System Menu ......................... 5 Video Window Function Option .................. 5 PTZ Control ........................6 PTZ Setup/Menu ......................
1 1 1 1 Network Network Network C C C C onnection Network onnection onnection onnection 1.1 Preparation Preparation Preparation Preparation This series speed dome product supports the Web access and management via PC. Web includes several modules: monitor channel preview, PTZ control, system configuration, alarm and etc.
Page 7
Figure 1-2 If it is your first time to login in, system pops up warning information to ask you whether install control webrec.cab or not. Please click OK button, system can automatically install the control. When system is upgrading, it can overwrite the previous Web too. If you can’t download the ActiveX file, please check whether you have installed the plug-in to disable the control download.
1.3 Live Interface Live Interface Live Interface Live Interface After you logged in, you can see the live monitor window. Now you can operate the speed dome via the WEB. See Figure 1-4. Figure 1-4 There are six sections: Section 1: Encode setup bar Section 2: Window adjust bar Section 3: System menu bar Section 4: Window function option bar...
Page 9
Please refer to the following sheet for detailed information. Parameter Function In normal network width environment, main stream can record Main stream audio/video file and realize network monitor. If network width is not sufficient, you can use sub stream to Sub (Extra) realize network monitor.
Figure 1-7 Please refer to the following sheet for detailed information. Parameter Function Video Brightness setup icon. It is to adjust Note: setup monitor video brightness. All the operations here apply to WEB end Contrast setup icon. It is to adjust only.
Figure 1-9 Please refer to the following sheet for detailed information. Parameter Function Click it to generate an alarm output. Alarm There are two alarm output icons since this series product output supports two relay output. Please note the alarm output interface may vary due to different series products.
Here you can view direction keys, speed, zoom, focus, iris button. See Figure 1-10. PTZ direction: PTZ supports eight directions: left/right/up/down/upper left/upper right/bottom left/bottom right/ fast positioning. Speed: The step 8 speed is faster than step 1. Figure 1-10 1.9 PTZ Setup/Menu PTZ Setup/Menu PTZ Setup/Menu PTZ Setup/Menu...
Page 13
Figure 1-12 Please refer to the following sheet for PTZ setup information. Parameter Function Select Scan from the dropdown list, click Start button, you can Scan begin scan operation. Default SN is 1. Input the preset value and then click View button, the camera Preset turns to the corresponding position of the preset.
2 2 2 2 Setup Setup Setup Setup 2.1 Camera Camera Camera Camera 2.1.1 Conditions Here you can set camera property. Adjust video parameter to get best preview effect. See Figure 2-1. Figure 2-1 Please refer to the following sheet for detailed information. Parameter Function Here you can set camera setup mode.
Page 15
It is to set camera lens sharpness, and sharpness control level. Sharpness It is to set camera video. It includes: hue/brightness/saturation/ Picture chroma control/gamma/picture flip/picture freeze. It is to reboot camera. Restart It is to restore factory default setup. Default Important Please make sure your purchased camera supports all the functions listed here.
Page 16
Figure 2-3 Please refer to the following sheet for detailed information. Parameter Function It is to set camera exposure mode. It includes: Exposure mode auto/manual/aperture has the priority/shutter has the priority. The default setup is auto. For the auto exposure mode, the gain, shutter and iris are in auto mode.
Page 17
In lower illumination environment, you can lower the cameras Slow shutter auto exposure time to capture the image and enhance the definition. For the moving object , the trail may appear. Please note it is valid in auto mode. It is to set camera min shutter value. Auto Slow Shutter Min value...
Page 18
Parameter Function It is to control noise. The higher the level is; the small the noise 2D NR is. Comparing with the previous one, the picture may become a little bit blurry. It is to control noise. The higher the level is, the small the noise 3D NR is.
Page 19
Figure 2-6 Please refer to the following sheet for detailed information. Parameter Function It is to set camera focus mode. It includes: auto/manual/semi Focus mode auto. It is to camera focus distance in case the focus distance is too Focus limit small and the focus goes to the enclosure.
Page 20
Figure 2-7 Please refer to the following sheet for detailed information. Parameter Function It is to enable/disable digital zoom. Digital zoom It is to set camera zoom speed. The bigger the value is, the Zoom speed faster the speed is. 2.1.1.7 Sharpness Sharpness interface is shown as in Figure 2-8.
Page 21
Please refer to the following sheet for detailed information. Parameter Function It is to set camera sharpness. The higher the sharpness is, the Sharpness clear the image is. The object edge becomes clear too. It is to set camera control level. The higher the value is, the Sharpness strong the control level is.
Page 22
System goes to preset video when you are calling a preset. Picture Freeze System does not show the video during the PTZ movement. System just directly goes to the preset. 2.1.1.9 Restart Restart interface is shown as in Figure 2-10. Figure 2-10 Please refer to the following sheet for detailed information.
Page 23
Figure 2-11 Please refer to the following sheet for detailed information. Parameter Function It is to restore camera parameter to factory default setup. Default 2.1.1.11 Profile Management Profile management interface is shown as in Figure 2-12. Figure 2-12 Please refer to the following sheet for detailed information.
Parameter Function There are three modes: normal/full-time/schedule. The default Profile setup is normal. Management It is to adopt the general parameter on the profile file. Normal It is to adopt day or night general parameter on the profile file Full-time all the time.
Page 25
Parameter Function There are four options: H.264, H.264B, H.264H, and Encode mode MJPEG encode mode. H.264 : Main Profile encode mode. H.264B :Baseline Profile encode mode. H.264H: High Profile encode mode. MJPEG: In this encode mode, the video needs general large bit stream to guarantee the video definition.
Page 26
Parameter Function There are four options: H.264, H.264B, H.264H, and Encode mode MJPEG encode mode. H.264 : Main Profile encode mode. H.264B :Baseline Profile encode mode. H.264B is mainly for Blackberry cell phone to realize the monitor. You need to enable the sub stream function in your camera and set the resolution as CIF.
Page 27
The snapshot interface is shown as in Figure 2-14. Figure 2-14 Please refer to the following sheet for detailed information. Parameter Function There are two modes: general (schedule) and Event Snapshot type (activation). General (schedule) snapshot is to snap in the specified period. Event (Activation) snapshot Is to snap when the motion detect, camera masking, local alarm event occurrence.
Page 28
Please refer to the following sheet for detailed information. Parameter Function Privacy mask Here you can privacy mask the specified video in the monitor video. Click Setup button, you can set privacy mask region. System max supports 4 privacy mask zones. Time Title You can enable this function so that system overlays time information in video window.
Please click the Save button to save current setup. Figure 2-16 2.1.3 Audio The audio interface is shown as below. See Figure 2-17. Important Please make sure you have enabled the video function, otherwise you can not enable the audio function.
Encode mode The encode mode of the main stream and extra stream include PCM, G.711A and G.711Mu. The setup here is for audio encode mode and the bidirectional talk encode both. 2.2 Network Network Network Network 2.2.1 TCP/IP The TCP/IP interface is shown as in Figure 2-18. Figure 2-18 Please refer to the following sheet for detailed information.
Page 31
IP Version It is to select IP version. IPV4 or IPV6. You can access the IP address of these two versions. Please note system needs to check the validity of all IPv6 addresses. The IP address and the default gateway shall be in the same IP section.
2.2.2 Connection The connection interface is shown as in Figure 2-19. Figure 2-19 Please refer to the following sheet for detailed information. Parameter Function It is the max Web connection for the same device. The value ranges from 1 connection to 20.
RTSP port Usually, the default value is 554. You do not need to input again if you are using the default value. When you are using QuickTime (Apple browser) or VLC play real-time video, you can use the following format to play.
PPPoE is set to connect to the internet. You can get an account from your IPS (Internet service provider), you can set here to dial to the interface. You can see the registered IP address in the interface if your setup is right. Please note, you need to go to the IP address item to view the device current device information.
Please refer to the following sheet for detailed information. Parameter Function Server Type You can select DDNS protocol from the dropdown list and then enable DDNS function. Server IP DDNS server IP address Server Port DDNS server port. Domain Name Your self-defined domain name.
Page 36
Figure 2-23 Please refer to the following sheet for detailed information. Parameter Function Input server address and then enable this function. SMTP Server Port Default value is 25. You can modify it if necessary. Anonymity For the server supports the anonymity function. You can auto login anonymously.
Parameter Function The send interval ranges from 0 to 3600 seconds. 0 means Interval there is no interval. Please note system will not send out the email immediately when the alarm occurs. When the alarm, motion detection or the abnormity event activates the email, system sends out the email according to the interval you specified here.
Figure 2-24 2.2.8 SNMP The SNMP interface is shown as in Figure 2-25. The SNMP allows the communication between the network management work station software and the proxy of the managed device. Please install the software such as MG MibBrowser 8.0c software or establish the SNMP service before you use this function.
Parameter Function SNMP Port The listening port of the proxy program of the device. It is a UDP port not a TCP port. The value ranges from 1 to 65535. The default value is 161 It is a string. It is a command between the manage process Read Community and the proxy process.
Figure 2-26 2.2.10 Multicast The multicast interface is shown as in Figure 2-27. Multicast is a transmission mode of data packet. When there is multiple-host to receive the same data packet, multiple-cast is the best option to reduce the broad width and the CPU load. The source host can just send out one data to transit.
2.2.11 IEEE802 IEEE802.1X works standing for local and metropolitan area networks and port based network access control protocol. It supports manual operation of the client to choose means of authenticating by which to control it to access to the Local Area Networks or not. It supports the ability to authenticate, to calculate fee, to ensure security and to maintain requirements.
Figure 2-29 Please refer to the following sheet for detailed information. Parameter Function Real-time The data packet of the network video monitor. monitor Command The non-monitor packet such as device setup and search. 2.3 PTZ 2.3.1 Protocol 2.3.1.1 Network PTZ Setup Network PTZ setup interface is shown as in Figure 2-30.
Parameter Function Protocol You can select from the dropdown list such as PELCOP, PELCOD. 2.3.1.2 Analog PTZ The analog PTZ is shown as in Figure 2-31. Figure 2-31 Please refer to the following sheet for detailed information. Parameter Function Address It is to set the corresponding speed dome address.
Page 44
PTZ speed Set PTZ movement speed. Idle motion Set camera idle operation. Power up Set camera operation when system boots up. PTZ restart Restart camera PTZ. Default Restore camera PTZ default setup. 2.3.2.1 Preset Preset interface is shown as in Figure 2-32. Figure 2-32 Please refer to the following sheet for detailed information.
Page 45
Click it to add a new preset. Clear Clear all presets setup. 2.3.2.2 Tour Tour interface is shown as below. See Figure 2-33. Figure 2-33 Please refer to the following sheet for detailed information. Parameter Function Tour No. System auto allocates. Tour title Set tour name.
Page 46
Save Click it to save current setup. Refresh Refresh current interface. 2.3.2.3 Scan Scan interface is shown as below. See Figure 2-34. Figure 2-34 Please refer to the following sheet for detailed information. Parameter Function Scan No. System auto allocates. Set scan speed here.
Page 47
Figure 2-35 Please refer to the following sheet for detailed information. Parameter Function Pattern No. System auto allocates. Begin pattern. Start Please note this function is null if you have not set a pattern. Click it you can see start/stop record buttons. Start record Click it to begin recording pattern setup.
Page 48
Figure 2-36 Please refer to the following sheet for detailed information. Parameter Function Please select privacy mask number from the dropdown list. Enable Check the box here to enable privacy mask function. Click Draw button, you can see edit column. You can drag and release mouse to set privacy mask region and size.
Page 49
Figure 2-37 Please refer to the following sheet for detailed information. Parameter Function PTZ speed Here you can set camera PTZ speed. 2.3.2.7 Idle Motion Idle motion interface is shown as below. See Figure 2-38. Figure 2-38...
Page 50
Please refer to the following sheet for detailed information. Parameter Function Enable Check the box here to enable idle motion function. Here you can set preset, scan, pattern, tour. Idle Motion Please note you need to set the corresponding function first if you want to use it. Idle time Set idle time.
Page 51
Figure 2-40 Please refer to the following sheet for detailed information. Parameter Function PTZ restart It is to reboot PTZ. 2.3.2.10 Default Default interface is shown as below. See Figure 2-41. Figure 2-41...
Please refer to the following sheet for detailed information. Parameter Function Default Restore PTZ factory default setup. 2.4 Event Event Event Event 2.4.1 Video detect 2.4.1.1 Motion Detect The motion detect interface is shown as in Figure 2-42. Figure 2-42 Figure 2-43...
Page 53
Figure 2-44 Please refer to the following sheet for detailed information. Parameter Function Enable You need to check the box to enable motion detection function. There are six levels. The sixth level has the highest sensitivity. Sensitivity Region There are six levels. The sixth level has the highest sensitivity. Region: If you select motion detection type, you can click this button to set motion detection zone.
Page 54
Parameter Function Relay out Enable alarm activation function. You need to select alarm output port so that system can activate corresponding alarm device when alarm occurs. Please note the relay output number here is for reference only. The alarm output number may vary due to different series products.
Please refer to the following sheet for detailed information. Parameter Function Enable You need to check the box to enable video masking function. There are six levels. The sixth level has the highest sensitivity. Sensitivity Working Video masking function becomes activated in the specified Period periods.
Page 56
The alarm activation interface is shown as in Figure 2-46. Figure 2-46 Please refer to the following sheet for detailed information. Parameter Function Enable You need to check the box to enable this function. Working This function becomes activated in the specified periods. Period There are six periods in one day.
Page 57
Parameter Function Record System auto activates motion detection channel to record once Channel alarm occurs (working with motion detection function). Please note you need to go to Storage-> Schedule to set current channel as general record. Record Delay System can delay the record for specified time after alarm ended. The value ranges from 10s to 300s.
2.4.3 Abnormality It includes five statuses: No SD card, capacity warning, SD card error, and disconnection and IP conflict. There are two interfaces for you reference. See Figure 2-48 through Figure 2-52. Figure 2-48 Figure 2-49 Figure 2-50...
Page 59
Figure 2-51 Figure 2-52 Please refer to the following sheet for detailed information. Parameter Function Event The abnormal events include: no disk, no space, disk error, net error, Type offline, IP conflict. You need to draw a circle to enable this function. System auto activates channel to record once an alarm occurs (For Record offline type only.
Parameter Function Send If you enable this function, system can send out email to alarm the email specified user. 2.5 Storage Storage Storage Storage 2.5.1 Record schedule and snapshot schedule In these two interfaces, you can add or remove the schedule record/snapshot setup. See Figure 2-53. There are three record modes: general (auto), motion detect and alarm.
Page 61
Figure 2-54 Please refer to the following sheet for detailed information. Parameter Function Event It includes: general, motion detect and alarm. Type Local It is to save in the SD card. It is to save in the FTP server. The local interface is shown as in Figure 2-55. Here you can view local SD card information. You can also operate the read-only, write-only, hot swap and format operation.
Figure 2-56 2.5.3 Record control The record control interface is shown as in Figure 2-57. Figure 2-57 Please refer to the following sheet for detailed information. Parameter Function Here you can select file size. Default setup is 60 minutes. Pack Duration Pre-record Please input pre-record value here.
There are three modes: Auto/manual/close. Record Mode You can select main stream or extra stream. Record Bit Stream 2.6 System System System System 2.6.1 General The general interface includes the general setup and the date/time setup. 2.6.1.1 General The general interface is shown as in Figure 2-58. Figure 2-58 Please refer to the following sheet for detailed information.
Figure 2-59 Please refer to the following sheet for detailed information. Parameter Function Here you can select date format from the dropdown list. Date format There are two options: 24-H and 12-H. Time Format The time zone of the device. Time zone It is to set system time.
Page 65
For the character in the following user name or the user group name, system max supports 6-digits. The space in the front or at the end of the string is null. The valid string includes: character, number, and underline. The max user amount is 20 and the max group amount is 8. You can add or delete user group. The factory default setup includes two levels: user and admin.
Page 66
Figure 2-61 Modify user It is to modify the user property, belonging group, password and rights. See Figure 2-62. Modify password It is to modify the user password. You need to input the old password and then input the new password twice to confirm the new setup.
Page 67
Figure 2-63 Add group: It is to add group and set its corresponding rights. See Figure 2-64. Please input the group name and then check the box to select the corresponding rights. It includes: live playback, record control, backup, PTZ control, user management and etc. Figure 2-64 Modify group Click the modify group button, you can see an interface is shown as in Figure 2-65.
Figure 2-65 2.6.3 Default The default setup interface is shown as in Figure 2-66. Please note system can not restore some information such as network IP address. Figure 2-66 2.6.4 Import/Export The interface is shown as in Figure 2-67. Figure 2-67...
Please refer to the following sheet for detailed information. Parameter Function It is to import the local setup files to the system. Import It is to export the corresponding system setup to your local PC. Export 2.6.5 Auto maintenance The auto maintenance interface is shown as in Figure 2-68. Here you can select auto reboot and auto delete old files interval from the dropdown list.
Figure 2-69 2.7 Information Information Information Information 2.7.1 Version The version interface is shown as in Figure 2-70. Here you can view system software version, WEB version, release date and etc. Please note the following information is for reference only. Figure 2-70 2.7.2 Log Here you can view system log.
Figure 2-71 Please refer to the following sheet for log parameter information. Parameter Function Log types include: system operation, configuration operation, data Type operation, alarm event, record operation, and user management, log clear. Set the start time of the requested log. Start time Set the end time of the requested log.
3 3 3 3 Alarm Alarm Alarm Alarm Click alarm function, you can see an interface is shown as in Figure 3-1. Here you can set device alarm type and alarm sound setup. When the specified alarm occurred (you have subscribed), system can record the corresponding alarm information on the right pane of the alarm list.
4 4 4 4 Log out Log out Log out Log out Click log out button, system goes back to log in interface. See Figure 4-1. You need to input user name and password to login again. Figure 4-1 Note: This manual is for reference only.
Page 75
IR Network Intelligent Speed Dome User’s Manual Version 1.0.0...
Page 76
Table of Contents 1 1 1 1 FEATURES AND FUNCTIONS FEATURES AND FUNCTIO NS................... 1 FEATURES AND FUNCTIO FEATURES AND FUNCTIO General Introduction General Introduction General Introduction General Introduction ..............................1 Features Features ..................................1 Features Features 1.2.1 On-Screen Menu ..............................1 1.2.2 Proportional Pan and Tilt ............................
Page 77
Login and Logout Login and Logout ................................ 6 Login and Logout Login and Logout 4 4 4 4 MENU ..........................9 MENU MENU MENU Screen Menu Index ..............................9 Self Self Self Self- - - - diagnosis System Information diagnosis System Information diagnosis System Information diagnosis System Information ........................
Page 78
Welcome Thank you for purchasing our product! This user’s manual is designed to be a reference tool for the operation of your system. Here you can find information about this speed dome features and functions, as well as a detailed menu tree. Please keep it well for future reference! Before installation and operation, please read the following safeguards and warnings carefully!
Page 79
Important Safeguards and Warnings 1. . . . Electrical safety All installation and operation here should conform to your local electrical safety codes. We assume no liability or responsibility for all the fires or electrical shock caused by improper handling or installation.
Page 80
6. About Accessories Always use all the accessories recommended by manufacturer. Before installation, please open the package and check that all the components are included in the package: Contact you local retailer ASAP if something is missing in your package.
Page 81
1 1 1 1 Features and Features and Features and Features and F F F F unction unction unctions s s s unction 1.1 General Introduction General Introduction General Introduction General Introduction This series IR network intelligent speed dome product is an integrated high intelligent speed dome. It adopts new configuration design and is easy for the project construction.
Page 82
1.2.9 Defog Customized defog setup in case the fog environment may affect the video quality. It is to enhance video resolution. 1.2.10 3D noise reduction Support 3D noise reduction setup to reduce the camera noise under the low illumination environment. It is to enhance video quality.
Page 83
2 2 2 2 Quick Configuration Tool Quick Configuration Tool Quick Configuration Tool Quick Configuration Tool 2.1 Overview Overview Overview Overview Quick configuration tool can search current IP address, modify IP address. At the same time, you can use it to upgrade the device.
Page 84
Figure 2-2 Select the “Open Device Web” item; you can go to the corresponding web login interface. See Figure 2-3. Figure 2-3 If you want to modify the device IP address without logging in the device web interface, you can go to the configuration tool main interface to set.
Page 85
Figure 2-4 After you logged in, the configuration tool main interface is shown as below. See Figure 2-5. Figure 2-5 For detailed information and operation instruction of the quick configuration tool, please refer to the Quick Configuration Tool User’s Manual included in the resources CD.
3 3 3 3 Web Web Operation Operation Operation Operation This series speed dome product supports the Web access and management via PC. Web includes several modules: live view, PTZ, setup, alarm, logout and etc. Speed dome factory default setup: IP address: 192.168.1.108.
Page 87
Figure 3-2 After installation, the interface is shown as below. See Figure 3-3. Please input your user name and password. Default factory name is admin and password is admin. Select the network connection type. Note: For security reasons, please modify your password after you first login. Figure 3-3 After you logged in, you can see the main window.
Page 88
Figure 3-4 Please refer to the Web Operation Manual included in the resource CD for detailed operation instruction.
4 4 4 4 Menu Menu Menu Menu 4.1 Screen Menu Index Note: ERR means current setup is invalid; you need to restores speed dome factory default setup. Slight difference may be found due to different series. SYSTEM SETTING SYSTEM INFORMATION… ADDR INFORMATION…...
Note: ERR means current setup is invalid. Please make sure all the cable connections are right. 4.2 S S S S elf elf elf elf- - - - diagnosis S diagnosis S diagnosis System diagnosis S ystem ystem I I I I nformation ystem nformation nformation...
4.4 Menu Operation In the speed dome main menu, you can use the left/right button on the keyboard or in the speed dome terminal menu to configure the system menu. Before setup, please move the cursor to the current item you want to configure.
ADDR TYPE : SOFT 4.4.1.2 Address Information ADDR-SOFT :001 BACK EXIT Move the cursor to SITE INFORMATION and then click confirm button. ADDR TYPE: System supports software address only. ADDR-SOFT: It is to display speed dome software address. Please use the left/right button on the keyboard or in the speed dome terminal menu to set.
Page 93
Move the cursor to CAMERA SETTING and then click confirm button, you can go to the submenu. WHITE BALANCE SETUP: Move the cursor to current option and then click confirm button, you can go to the third menu. EXPOSURE SETTING: Move the cursor to current option and then click confirm button, you can go to the third menu.
Page 94
4.4.3.2 Exposure Setting AE MODE : AUTO AGC GAIN LIMIT :03 GAIN SETTING : 02 HIGH GAIN :ON SHUTTER SLOW SHUTTER LIMIT :1/50 :1/25 IRIS SETTING NOISE REDUCTION :11 :03 EXPOSURE COMP : 08 3D NOISE REDUCTION SLOW AE : 01 :OFF SLOW SHUTTER HIGH LIGHT REDUCE...
Page 95
HIGH LIGHT REDUCE: It is to reduce the abruptly strong video on the video in case it affects the video quality. Please click the left/right button to set. EXPOSURE RESTRAIN: It is to restrain the abrupt high light on the video in case it affects the video quality.
Page 96
: It is to set video shadow correction level. Please use the left/right button on the SHADOW CORRECTION keyboard or in the speed dome terminal menu to set. BACK: Go back to previous menu. EXIT: Log out system menu. 4.4.3.5 Day/Night Setting Move the cursor to DAY/NIGHT SETTING and then click confirm button, you can go to the submenu.
Page 97
BACK: Go back to previous menu. EXIT: Log out system menu. 4.4.3.7 Image Adjust Move the cursor to IMAGE ADJUST and then click confirm button to go to the submenu to set. : SATURATION : CHROMA SUPPRESS : GAMMA : CONTRAST BACK EXIT...
DIGITAL ZOOM ::OFF DZOOM LIMIT :X3 PICTURE FLIP :OFF FREEZE FUNC :OFF STABLE :OFF CAMERA FACTORY DEFAULT CAMERA RESTATRT BACK EXIT DIGITAL ZOOM: You can use the left/right button to enable/disable the digital zoom function. DZOOM LIMIT: Here you can set the threshold of the digital zoom. PICTURE FLIP: There are two options: on/off.
Page 99
BACK: Go back to previous menu. EXIT: Log out system menu. 4.4.4.1 Preset Setup PRESET NO :001 TITLE :PRESET001 SETTING CALL BACK EXIT Move the cursor to PRESET button and then click confirm button to go to set interface. PRESET NO: Please use left/right key to modify preset number. The different protocols support different preset values.
Page 100
EXIT: Log out system menu. 4.4.4.3 Scan AUTO SCAN NO : 001 SET LEFT LIMIT SET RIGHT LIMIT SCAN SPEED :160 CALL STOP BACK EXIT Move the cursor to SCAN button and then click confirm button. AUTO SCAN NO:Here is to set auto scan number. Please use the left/right button on the keyboard or in the speed dome terminal menu to set.
Page 101
When you move the cursor to one tour number, please click confirm button to set the tour. Please use up/down button to set preset number, dwell time and speed. Use the left/right button to go to the next tour. Click confirm button you can exit the setup. After you completed the setup, move the cursor to back button to go to the previous interface.
Page 102
IDLE FUNC :OFF IDLE TIME :010MIN IDLE ACTION :PRESET PARAMETER :NONE SAVE BACK EXIT When there is no available command for specified time, dome automatically goes on the previous set functions. IDLE FUNCTION :There are two modes ON/OFF. Please use left/right key to set. •...
Page 103
WEEK: Here you can set the week information. Please use the left/right button to set. You can set • for one day, or you can set for the whole week. START TIME: Here you can set the task begin time. Move the cursor to current item and then click •...
Page 104
PRIVACY MASK: Here you can set the privacy mask number and etc. It includes the third menu. • Please move the cursor to the current item and then click the confirm button to go to the next interface. PTZ SPEED: It is to set PTZ speed. Please use the left/right button to set. •...
Page 105
PRIVACY MASKING: There are two settings: on and off. Please go to the corresponding privacy mask zone and click left/right button to set. RESIZE:It is to adjust the privacy zone size. Move the cursor to current item and use the left/right button on the keyboard or in the speed dome terminal menu to set .Please continue pressing direction button to widen or narrow zone size.
HEATER CONTROL: It is to set temperature control mode. It includes three modes: auto/normal open/normal close. Please use the left/right button on the keyboard or in the speed dome terminal menu to set. OPEN TEMPERATUREP: This function is on when the heater control mode is auto. It is for you to set temperature to enable the heater.
5 5 5 5 Cable Connection Cable Connection Cable Connection Cable Connection 5.1 Combination C C C C able able able C C C C onnection able onnection onnection onnection The speed dome combination cable includes network cable, audio/video cable connection port, RS485 connection port, alarm input and output port.
5.2.1 System Connection Please refer to Figure 5-1 for system connection information. Network AC220V Power Output Input Output Transfor Figure 5-1 5.2.2 Alarm Connection Please refer to Figure 5-2 for alarm connection information. Figure 5-2...
6 6 6 6 FAQ 6.1 Daily Maintenance Please clean dome cover regularly to get vivid image. Handle the cover with care. Use water to wash. Don’t use cloth to clean. Note: The sweat from your hand may erode plating surface, your nail may scrape dome cover resulting in blur image.
Page 110
7 7 7 7 Append Appendix Ⅰ ix Ⅰ Lightning Lightning Proof and Surge Protection Proof and Surge Protection Append Append ix Ⅰ ix Ⅰ Lightning Lightning Proof and Surge Protection Proof and Surge Protection This series speed dome adopts TVS lighting protection technology. It can effectively prevent damages from various pulse signals below 1500W, such as sudden lighting and surge.
Page 111
8 8 8 8 Appendix Appendix 2 2 2 2 Toxic or Hazardous Materials or Elements Toxic or Hazardous Materials or Elements Appendix Appendix Toxic or Hazardous Materials or Elements Toxic or Hazardous Materials or Elements Toxic or Hazardous Materials or Elements Component Name Cr VI...
Page 112
Note This manual is for reference only. Slight difference may be found in the user interface. • All the designs and software here are subject to change without prior written notice. • All trademarks and registered trademarks are the properties of their respective owners. •...
Need help?
Do you have a question about the DNA1990 and is the answer not in the manual?
Questions and answers