Function Check - Assa Abloy 179B S4 Mounting Instruction

Emergency exit device

Advertisement

Available languages

Available languages

ASSA 179B S4 Emergency exit device
Assa 1125 Panikutrymningsbeslag
8
Handle
A
1
Mount the device [
],
the attachment plate
2
[
] for theseal strip
and the lever handle
3
follower [
] with four
M5 screws.
NOTE!
If the B- or
C-mesurement of
the door is less than
22 mm the 3 mm
distance plate ASSA
357932 shall be
used. Not Included.
9

Function check

ASSA AB 090891
Edition 5
NOTE! For right hand devices the exit handle
is mounted in angle 11 o'clock and for left
hand devices in angle 1 o'clock.
A
Test the function
by pressing the
exit handle
downwards.
Dead bolt/latch/
latches shall
then retract and
the door shall be
possible to open.
After opening
procedure the
exit handle
shall easily
return to its
starting position.
5/7
Ensure that the
nipples are mounted
on the outside
10
Exit label & Seal strip
A
Attach the plastic seal strip
NOTE! Only seal strip recommended
by ASSA is allowed.
1
B
B
Attach enclosed
after glowing
exit label on the
exit handle, the
arrow on the
label shall point
in the maneuve-
ring direction