Download Print this page
IOTA ILB-CP Instruction Manual

IOTA ILB-CP Instruction Manual

“l” open board design emergency lighting equipment for led

Advertisement

Quick Links

P.O. BOX 11846 TUCSON, AZ 85734
(520) 294-3292
• FAX (520) 741-2837
www.iotaengineering.com
When using electrical equipment, basic safety precautions should always be followed, including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
CAUTION – Connect the battery to the unit before applying A.C. power.
1.
CAUTION – To prevent electrical shock, do not mate unit connector until installation is complete and A.C. power is
2.
supplied to the unit.
3.
CAUTION – This fixture provides more than one power supply output source. To reduce the risk of electrical
shock, disconnect both normal and emergency sources by turning off the A.C. branch circuit and by disconnect-
ing the unit connector. In addition, the circuit board should be mounted so that no live parts are accessible during
routine maintenance.
CAUTION – The integral, high temperature Ni-Cad battery or components of this unit are not replaceable. Replace
4.
the entire unit when necessary and recycle or dispose of properly.
5.
CAUTION – Installation and servicing should be performed by qualified personnel only. De-energize before servicing.
6.
DO NOT USE OUTDOORS. The ILB-CP is for use with grounded, UL Listed, indoor fixtures. Not for use in heated
air outlets or hazardous locations. The acceptability of the combination must be determined by Underwriters Labora-
tories. Refer to the Engineering Considerations section for proper installation.
7.
The ILB-CP requires an unswitched A.C. power source of 120 to 277 volts AC, 50/60Hz.
The ILB-CP and A.C. driver must be on the same branch circuit.
8.
9.
Do not mount near gas or electric heaters.
The ILB-CP should be mounted in locations and at heights where it will not readily be subjected to tampering by
10.
unauthorized personnel.
11.
The ILB-CP will supply 10-60VDC output at the individual rated specification for 90 minutes. See individual units
for output specifications.
12.
The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition, void
warranty, and result in non-compliance with UL specifications.
13.
Do not use this equipment for other than intended use.
14.
Install in accordance with the National Electrical Code and local regulations.
15.
Lighting fixture manufacturers, electricians, and end-users need to ensure product system compatibility before
final installation.
CLASS 2 OUTPUT
INSTRUCTION MANUAL
IMPORTANT SAFEGUARDS
SAVE THESE INSTRUCTIONS
ILB-CP
"L" OPEN BOARD DESIGN
EMERGENCY LIGHTING EQUIPMENT
FOR LED
Patented. See iotaengineering.com/patents for more details

Advertisement

loading

Summary of Contents for IOTA ILB-CP

  • Page 1 CAUTION – Installation and servicing should be performed by qualified personnel only. De-energize before servicing. DO NOT USE OUTDOORS. The ILB-CP is for use with grounded, UL Listed, indoor fixtures. Not for use in heated air outlets or hazardous locations. The acceptability of the combination must be determined by Underwriters Labora- tories.
  • Page 2 CAUTION: Before installing, make certain the A.C. power is off and the ILB-CP unit connector is disconnected. 1. FIXTURE The ILB-CP can be used with most LED loads that operate at 10-60 VDC. See the ILB Model Specification Chart for output specifications of the unit being installed. ILB MODEL SPECIFICATION CHART...
  • Page 3 OPERATION Normal Mode – A.C. power is present. The A.C. driver operates the LED load as intended. The ILB-CP is in the standby charging mode. The TBTS will be lit providing a visual indication that the battery is being charged.
  • Page 4 TYPICAL WIRING DIAGRAM For other diagrams, consult our Customer Service. ILB-CP-L OPEN BOARD WITH TBTS TEST ACCESSORY BLACK (120V) SWITCHED OR LED OUTPUT (-) LED INPUT(+) AC (NORMAL) UNSWITCHED ORANGE (277V) LED OUTPUT (+) LED INPUT (-) LOAD DRIVER WHITE...

This manual is also suitable for:

Ilb cp10 l