ELECTRICAL WIRING DIAGRAM

Any electrical re-wiring of this appliance must be done by a qualified electrician. This wiring must
be done in accordance with local codes and/or in Canada with the current CSA C22.1 Canadian
Electrical Code, and for US installations, the National Electrical Code ANSI/NFPA NO 70.
If repairing or replacing any electrical component or wiring, the original wire routing, color
coding and securing locations must be followed.
1. Power Cord
2. Bushing Strain Relief
3. Fan
4. Temperature Limiter
5. Rocker Switch

CARE AND MAINTENANCE

Always disconnect the appliance from the main power supply and allow it to cool before
any servicing operation.
The motors used on the fan heater and flame blower are pre-lubricated for extended bearing life
and require no further lubrication. However, periodic cleaning/vacuuming of the appliance around
the air intake and exhaust, as well as the fan heater is recommended. For heavy or continuous
use, periodic cleaning must be done more frequently. If the heater blows alternating cold and
warm air, check the fan for free movement and for debris restricting air flow. If the fan does not
move freely, the unit must be turned off and the fan replaced immediately in order to prevent
further damage to the unit.
WHITE
GREEN
13
BLACK
RED
FAN