ELECTRICAL CONNECTION

A 15 amp, 120 Volt, 60 Hz circuit with a properly grounded outlet is required. Preferably, the
fireplace will be on a dedicated circuit as other appliances on the same circuit may cause the circuit
breaker to trip or the fuse to blow when the heater is in operation. Plan the installation to avoid the
use of an extension cord. Extension cords are for temporary use only. If an extension cord must be
used, it must be UL/CSA certified, rated at 10A (1250W), 125V maximum with 16 AWG minimum
and constructed of two current carrying conductors with ground. A heavy duty extension cord with
the shortest length possible for the connection is recommended and must not be longer than 50 ft.
(15.2 m). Do not coil or cover the extension cord.
Electrical outlet wiring must comply with local building codes and other applicable regulations to
reduce the risk of fire, electrical shock and injury to persons.
Do not use this fireplace if any part of it has been under water. Immediately call a qualified
service technician to inspect the fireplace and replace any part of the electrical system which
has been under water.

GROUNDING INSTRUCTIONS

This heater is for use on 120 volts. The cord has a plug as shown at A in Fig. 20. An adapter as
shown at C is available for connecting three-blade grounding-type plugs to two-slot receptacles.
The green grounding lug extending from the adapter must be connected to a permanent ground
such as a properly grounded outlet box. The adapter should not be used if a three-slot grounded
receptacle is available.
OPERATING INSTRUCTIONS
Using rocker switch, turn blower on and check for operation. Turn on rocker switch to the desired
position. In the MAN position it will remain constantly on. AUTO position will be controlled by the
temperature sensor. To stop the operation turn rocker switch to the O position.
Grounding Pin
Adapter
Fig. 20
Cover of
Grounded
Outlet Box
Metal Screw
Grounding Means
12

Advertisement

Table of Contents
loading

This manual is also suitable for:

0293810

Table of Contents