Grundfos MAGNA3 Manual page 53

Circulator pumps
Hide thumbs Also See for MAGNA3:
Table of Contents

Advertisement

MAGNA3
MAGNA3 80-100 F (N)
Proportional pressure
H
[ft]
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
0
0
40
80
120
160
200
240
P1
[W]
1,100
1,000
900
800
700
600
500
400
300
200
100
0
P1 [W]
Speed
230 V
Min.
1017
Max.
The pump incorporates overload protection.
Net weights
[lb (kg)]
66.2 (30.0)
B2
B4
B7
B6
Pump type
L1
14.17 (360)
MAGNA3 80-100 F (N)
D3
5.91 (150)
For product numbers, see page 62.
Constant pressure
H
[ft]
38
AUTO
ADAPT
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
0
280
Q [US gpm]
0
40
80
120
P1
[W]
1,100
1,000
900
800
700
600
500
400
300
200
100
0
I
[A]
1
230 V
31
0.32
4.51
Ship. vol.
3
3
[ft
(m
)]
2.47 (0.07)
H3
H1
H6
H4
H2
L5
B1
8.03 (204)
3.31 (84)
D4
D5
7.87 (200)
0.75 (19)
Performance curves and technical data
H
[ft]
38
36
34
10 V
32
30
9 V
28
26
8 V
24
22
20
7 V
18
16
6 V
14
12
5 V
10
4 V
8
3 V
6
2 V
4
2
0
160
200
240
280
Q [US gpm]
0
40
*
External setpoint influence shown with a
setpoint of H
Connections:
GF80 flanges.
See
Pipe
System pressure:
Max. 175 psi (1.2 MPa) (12 bar).
Liquid temperature:
14 to 230 °F (-10 to +110 °C) (TF 110).
Specific EEI:
0.17.
Dimensions [in (mm)]
B2
B4
B6
6.46 (164)
2.87 (73)
6.42 (163)
H1
H2
H3
3.7 (94)
12.52 (318)
16.22 (412)
1 x 230 V, 60 Hz
0-10 volts*
80
120
160
200
240
280
Q [US gpm]
max
connections, page 61.
ØD5
B7
D1
D2
6.42 (163)
3.15 (80)
5.2 (132)
H4
H6
4.53 (115)
2.6 (66)
9
53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magna3 nMagna3 d

Table of Contents