8.Host computer configuration instructions

The figure below shows the E95-DTU (900SLxx-485) configuration host computer display interface, the user
can switch to the configuration mode through the MODE button, and quickly configure and read parameters on the
host computer.
In the configuration of the host computer, the radio address, frequency channel, network ID, and key are all
displayed in decimal mode, and the value range of each parameter is as follows::
Network address: 0~65535
Frequency channel: 0~81
Network ID: 0~255
Key: 0~65535
Users need to pay special attention when using the host computer to configure the relay mode, because in the
host computer, each parameter is displayed in decimal mode, so the radio address and network ID need to be
converted to decimal when filling in the station address and network ID. If the network ID input by transmitter
A is 02, and the network ID input by receiver B is 10, then when relay terminal R sets the radio address,
convert the hexadecimal value 0X020A to decimal value 522 and fill in as relay terminal R the station address.
That is, the radio address value that the relay terminal R needs to fill in at this time is 522.
Copyright ©2012–2022,Chengdu Ebyte Electronic Technology Co.,Ltd.
E95-DTU(900SLxx-485) User Manual