At the same time, node 1 and node 2 have the same address, so the data sent by node 1 can be received by node 2.
② Secondary Relay
The ADDH \ ADDL for relay 2 was 33,05, respectively.
So the relay 2 can forward the data of the relay 1 to the network NETID: 05.
Thus, the nodes 3 and the node 4 can receive the node 1 data. Node 4 normally outputs data, and node 3 has different addresses from
node 1, so it does not output data.
③ bi-directional relay
As configured, data nodes 2 and 4 sent by nodes 1 may be received, and data sent by nodes 2 and 4 can also be received by nodes 1.

8. Description of the upper computer machine configuration

The following figure shows E95M-DTU (400SLxx-xxx) configure the upper machine display interface. Users can switch to
configuration mode through the MODE key, and quickly configure and read parameters in the upper machine.
In the configuration computer, the radio address, frequency channel, network ID and key are all in decimal display mode,
including the value range of each parameter:
Network address: 0~65535