Air Speed Class; Current Parameters; Send And Receive Length And Subcontracting Method - Ebyte E95-DTU User Manual

Hide thumbs Also See for E95-DTU:
Table of Contents

Advertisement

Chengdu Ebyte Electronic Technology Co.,Ltd.
Note: The lower the transmit power, the closer the transmission distance, but the working current will not decrease
proportionally, it is recommended to use the maximum transmit power.

3.5 air speed class

Model Specifications
E95-DTU(900SLxx-485
)
Note: The higher the air rate setting, the faster the transmission rate and the closer the transmission distance;
therefore, if the rate meets the usage requirements, it is recommended that the airspeed be as low as possible.

3.6 Current parameters

Model Specifications
E95-DTU(900SL22-485)
E95-DTU(900SL30-485)
Note: It is recommended to reserve more than 50% current margin when selecting the power supply, which is
conducive to the long-term stable operation of the radio.

3.7 Send and receive length and subcontracting method

Model Specifications
E95-DTU(900SLxx-485
)
Notes:
If the data received by the radio at a time is larger than the capacity of a single packet, the excess data will be
automatically allocated to the second transmission until the transmission is completed.;
The data received by the radio at a time cannot be larger than the buffer capacity.
Copyright ©2012–2022,Chengdu Ebyte Electronic Technology Co.,Ltd.
Default air
number
rate
levels
bps
2.4k
6
Emission
current
mA
12V
32.65
158.4
cache size
1000 ebytes
air speed class
of
kbps
2.4、4.8、9.6、19.2、38.4、62.5
receive current mA
12V
14.58
15.8
Subcontracting
32/64/128/240 bytes can be sent by sub-packet
setting by command
E95-DTU(900SLxx-485) User Manual
sleep current mA
12V
7.29
7.73