Before a rear venting option is installed the dryer must be changed from the front venting factory setup. Remove the
outlet grille from the front left-hand side and replace with the outlet cover from the rear left-hand side. These covers
should be gently pried at the sides to prevent damage.

External Venting Options

• Kits are available that allow the dryer to be vented upwards or to the
side.
• The dryer can be vented directly through the wall with a kit, in
combination with the duct adaptor supplied with the dryer.
The vent system should be less than two metres long
with no more than three 90⁰ bends.
Internal Venting
Front venting is the only option for internal venting. The dryer is set up for
front venting when it leaves the factory.
Where possible all efforts should be made to vent the
dryer externally to avoid moisture build up around the
dryer.
https://producthelp.fisherpaykel.com/au/Dry/Dryers/Vented/DE4560M1/User_Guide_DE4560M1/03_Installation_Instructions
External venting with kit part
number PD-DK4W
Updated: Thu, 27 Jan 2022 05:02:50 GMT